Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for March 31, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/30/2000 - 03/31/2000

                              ** EVENT NUMBERS **

36809  36844  36845  36846  36847  36848  

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   36809       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  U.S. ARMY                            |NOTIFICATION DATE: 03/17/2000|
|LICENSEE:  U.S. ARMY                            |NOTIFICATION TIME: 15:53[EST]|
|    CITY:  ROCK ISLAND              REGION:  3  |EVENT DATE:        03/17/2000|
|  COUNTY:                            STATE:  IL |EVENT TIME:        12:00[CST]|
|LICENSE#:  12-00722-06           AGREEMENT:  Y  |LAST UPDATE DATE:  03/30/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN JACOBSON        R3      |
|                                                |AL BELISLE           R2      |
+------------------------------------------------+DON COOL             NMSS    |
| NRC NOTIFIED BY:  JEFF HAVENNER                |CHARLES MILLER       IRO     |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DISCOVERY THAT AN M43A1 CHEMICAL AGENT DETECTOR CELL MODULE CONTAINING 250   |
| �Ci OF AMERICIUM-241 HAD BEEN MISSING FROM FT. BRAGG (NORTH CAROLINA) SINCE  |
| APRIL 1996                                                                   |
|                                                                              |
| Late yesterday afternoon (03/16/00), representatives from Ft. Bragg, North   |
| Carolina, requested the U.S. Army in Rock Island, Illinois, to help trace    |
| files for documentation regarding a cell module that was discovered to be    |
| missing from an M43A1 chemical agent detector.  (The cell module contained   |
| 250 �Ci of americium-241.)  The most recent documentation found related to   |
| the missing cell module indicated that it was last seen at Ft. Bragg in      |
| April of 1996.  More recent paperwork has not yet been found.  The licensee  |
| determined this event to reportable at approximately 1200 CST today          |
| (03/17/00).                                                                  |
|                                                                              |
| The licensee hypothesized that the M43A1 chemical agent detector may have    |
| been turned into a maintenance unit at some point.  If the device tested     |
| with bad air flow, the maintenance unit could have replaced several items    |
| including the cell module.  At this time, it is believed that the cell       |
| module in question may have been removed (without any paperwork) and that    |
| the device may have been returned without a replacement cell module          |
| installed.                                                                   |
|                                                                              |
| The licensee stated that there does not appear to be any likelihood that the |
| general public will get involved with this issue.  The licensee plans to     |
| submit a 30-day written report to the NRC Region 3 office.                   |
|                                                                              |
| (Call the NRC operations officer for licensee contact information.)          |
|                                                                              |
| * * * UPDATE AT 1420 ON 3/30/00 BY MOHS, RECEIVED BY WEAVER * * *            |
|                                                                              |
| The module was found on March 23, 2000.  The Operations Center notified the  |
| R3DO (Gardner) and R2DO (Caudle) and NMSS (Sherbini).                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36844       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 03/30/2000|
|    UNIT:  [] [3] []                 STATE:  NY |NOTIFICATION TIME: 09:46[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        03/30/2000|
+------------------------------------------------+EVENT TIME:        08:50[EST]|
| NRC NOTIFIED BY:  MIKE TESORIERO               |LAST UPDATE DATE:  03/30/2000|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MICHELE EVANS        R1      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| COMPONENT COOLING WATER SYSTEM OUTSIDE OF DESIGN BASIS                       |
|                                                                              |
| "At approximately 0850 hours on March 30th, 2000, it was determined that one |
| loop of the Component Cooling Water (CCW) system piping located in the Spent |
| Fuel Storage Building (FSB) was not in compliance with FSAR design criteria. |
| The FSAR says that CCW is protected from tornadoes and tornado generated     |
| missiles by structures designed to withstand such loading. The CCW piping    |
| located in the FSB is not protected by the structure. This was identified as |
| an issue and addressed as part of the 10CFR50.54(f) program at Indian Point  |
| 3. The issue was not considered reportable when first identified because     |
| tornado protection from the effects of missiles can be provided by           |
| redundancy. An evaluation has shown that the CCW piping can sustain limited  |
| damage from a tornado missile and that the design function of the system can |
| be performed with this damage. Operator action is depended upon to initiate  |
| makeup water to the CCW system, a current design basis. When a 10CFR50.59    |
| evaluation determined that the criteria for the CCW tornado protection could |
| not be changed without prior NRC approval, the issue was determined to be    |
| reportable because the CCW system could not be shown to be in accordance     |
| with FSAR design basis. No corrective actions were immediately required      |
| because current administrative controls are sufficient to assure system      |
| operability."                                                                |
|                                                                              |
| The NRC resident inspector has been informed of this report by the licensee. |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   36845       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  GE PLASTICS                          |NOTIFICATION DATE: 03/30/2000|
|LICENSEE:  GE PLASTICS                          |NOTIFICATION TIME: 14:30[EST]|
|    CITY:  WASHINGTON               REGION:  2  |EVENT DATE:        03/30/2000|
|  COUNTY:                            STATE:  WV |EVENT TIME:        09:30[EST]|
|LICENSE#:  47-08944-05           AGREEMENT:  N  |LAST UPDATE DATE:  03/30/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CAUDLE JULIAN        R2      |
|                                                |MR. SHERBINI         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  TAMMY MORROW                 |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOST SOURCE                                                                  |
|                                                                              |
| The licensee reported the loss of a 15 mCi nickel-63 source from their       |
| Washington, WV facility.   Ni-63 is a low energy beta emitter and has no     |
| gamma.  The source is used in an electron capture device and was last seen   |
| in July of 1999 in the licensee's laboratory.  Contact information is        |
| available from the Operations Center.                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36846       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BEAVER VALLEY            REGION:  1  |NOTIFICATION DATE: 03/30/2000|
|    UNIT:  [1] [] []                 STATE:  PA |NOTIFICATION TIME: 15:45[EST]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        03/30/2000|
+------------------------------------------------+EVENT TIME:        12:04[EST]|
| NRC NOTIFIED BY:  GEORGE STOROLIS              |LAST UPDATE DATE:  03/30/2000|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MICHELE EVANS        R1      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ESF ACTUATION                                                                |
|                                                                              |
| "At 1204 on March 30, 2000, an 18 month automatic-load sequencing            |
| operational surveillance test was being conducted on the No. 1 Emergency     |
| Diesel Generator (EDG) during a refueling at the Beaver Valley Power Station |
| (BVPS) Unit No. 1. The power to the 4KV 1AE Emergency Bus was being supplied |
| by the operating No. 1 EDG and the Emergency Bus 4KV-1AE was separated from  |
| offsite power sources. The EDG output breaker E9 unexpectedly opened and     |
| re-closed three times before the breaker remained open, deenergizing the     |
| 4KV-1AE Emergency Bus. The cause of this event is not currently known and is |
| being investigated. Power was restored to the 4KV 1 AE Emergency Bus at 1228 |
| from the offsite power source. The No.1 EDG was subsequently shutdown and    |
| remains out of service. The redundant train reactor decay heat cooling and   |
| spent fuel pool cooling remained in service throughout this event. Reactor   |
| coolant temperature and spent fuel pool temperature remained constant. The   |
| redundant 4KV 1DF Emergency Bus and No. 2 EDG remained unaffected by this    |
| event.                                                                       |
|                                                                              |
| "This condition is being reported pursuant to 10CFR50.72(b)(2)(ii) as an     |
| event that resulted in an automatic actuation of an Engineered Safety        |
| Feature. De-energizing the 1 AE Emergency Bus actuated an automatic EDO      |
| signal and output breaker E9 closure. The EDG had been running, however, and |
| the output breaker opened and re-closed three times before remaining open."  |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36847       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  LOUISIANA DEPT OF ENV QUALITY        |NOTIFICATION DATE: 03/30/2000|
|LICENSEE:  FORMOSA PLASTICS                     |NOTIFICATION TIME: 16:48[EST]|
|    CITY:  BATON ROUGE              REGION:  4  |EVENT DATE:        03/30/2000|
|  COUNTY:                            STATE:  LA |EVENT TIME:             [CST]|
|LICENSE#:  LA-4042-LO1           AGREEMENT:  Y  |LAST UPDATE DATE:  03/30/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |KRISS KENNEDY        R4      |
|                                                |JOHN GREEVES         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  COREY MEAUX                  |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT                                                       |
|                                                                              |
| A 100 mCi Cs-137 source was found at the Southern Scrap Yard in Baton Rouge, |
| LA.  The source was part of a level gauge used by Formosa Plastics.  The     |
| source had not been opened and there was no spread of contamination.   The   |
| manufacturer of the source, Texas Nuclear Technologies, will recover the     |
| source.  The source is currently in a roped off area at the scrap yard.  The |
| State is still investigating how the source ended up in the scrap yard.      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36848       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 03/30/2000|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 18:54[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        03/30/2000|
+------------------------------------------------+EVENT TIME:        16:20[EST]|
| NRC NOTIFIED BY:  JAMES HURCHALLA              |LAST UPDATE DATE:  03/30/2000|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION                                                         |
|                                                                              |
| A DEAD LOGGERHEAD SEA TURTLE WAS RECOVERED FROM THE INTAKE CANAL AT          |
| APPROXIMATELY 1600.  THE FLORIDA FISH AND WILD LIFE CONSERVATION COMMISSION  |
| WAS NOTIFIED AT 1620.  THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR.     |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021