The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for March 29, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
03/28/2000 - 03/29/2000
** EVENT NUMBERS **
36834 36839 36840 36841 36842 36843
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 36834 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/24/2000|
|LICENSEE: HTS, INC CONSULTANTS |NOTIFICATION TIME: 17:25[EST]|
| CITY: HOUSTON REGION: 4 |EVENT DATE: 02/08/2000|
| COUNTY: STATE: TX |EVENT TIME: 12:00[CST]|
|LICENSE#: TX-L-02757 AGREEMENT: Y |LAST UPDATE DATE: 03/28/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |LAWRENCE YANDELL R4 |
| |LARRY CAMPER NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES OGDEN | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN / RECOVERED CPN NUCLEAR GAUGE IN HOUSTON, |
| TX |
| |
| The following text is from the facsimile received from the Texas Department |
| of Health: |
| |
| "Theft/Recovery of a nuclear gauge - licensee notified the agency [Texas |
| Department of Health] Feb 8, 2000. Reports lost in mail. Faxed information |
| today at request of Incident Investigation. Gauge recovered intact Feb 14, |
| 2000. Leak tested Feb 15, 2000 was fully satisfactory." |
| |
| * * * UPDATE AT 1255 ON 03/28/00 BY JAMES OGDEN TO JOLLIFFE * * * |
| |
| The following is a more detailed version of the above Agreement State |
| Report: |
| |
| Texas Licensee #TX-L-02757, HTS, Inc. Consultants, Houston, Texas, reported |
| to Texas Department of Health, Bureau of Radiation Control, the theft of a |
| nuclear gauge in it's transport box from the bed of a company pickup truck |
| on February 8, 2000. Gauge Manufacturer: CPN, Model: MC-3. Serial Number: |
| M35116369. Two sealed sources: 1) Cs-137, maximum activity 10 millicuries |
| and 2) Am-241/Be, maximum activity 50 millicuries. The gauge was stolen |
| between 5:45 a.m. and 1:45 p.m. from a jobsite. Incident Report Number |
| 16656300-H was filed with the Houston Police Department on February 8, 2000. |
| Ten local pawn shops were notified by the licensee. The stolen gauge was |
| discovered in a lot adjacent to Hemmi Autoworks, Houston, TX by the |
| facility owner, Richard "Butch" Hemmi and reported to the City of Houston, |
| Bureau of Occupational Health and Radiation Control. This organization |
| recovered all components of the gauge intact on February 14, 2000 (Gauge, |
| Transport box, Calibration Block, Guide Pin, Guide Plate, and paperwork of |
| the last leak test.) The gauge was satisfactorily leak tested on February |
| 15, 2000. The gauge was returned to storage and to service with the Texas |
| licensee. |
| |
| The NRC Operations Officer notified the R4DO Kriss Kennedy and NMSS EO Brian |
| Smith. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 36839 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/28/2000|
|LICENSEE: FUGRO-McCLELLAND, INC |NOTIFICATION TIME: 12:27[EST]|
| CITY: FORT WORTH REGION: 4 |EVENT DATE: 03/28/2000|
| COUNTY: STATE: TX |EVENT TIME: [CST]|
|LICENSE#: TX-L-05082 AGREEMENT: Y |LAST UPDATE DATE: 03/28/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |KRISS KENNEDY R4 |
| |BRIAN SMITH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES OGDEN | |
| HQ OPS OFFICER: DICK JOLLIFFE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN / RECOVERED TROXLER NUCLEAR GAUGE IN |
| ARLINGTON, TX |
| |
| Texas Licensee #TX-L-05082, Fugro-McClelland (Southwest), Inc., Fort Worth, |
| Texas, reported to Texas Department of Health, Bureau of Radiation Control, |
| the theft of a nuclear gauge from it's unsecured transport box sitting near |
| a work site at the General Motors Plant in Arlington, Texas. The gauge was |
| unsecured and the source rod was not locked, as the operator was going to |
| use the gauge after a short discussion approximately 100 feet from the |
| transport box. Gauge Manufacturer: Troxler, Model: 3411-B, Serial Number: |
| 10390. Two sealed sources: 1) Cs-137 with nominal activity of 10 |
| millicuries and 2) Am-241/Be, nominal activity 40 millicuries. The stolen |
| gauge was discovered along a local street several blocks from the GM Plant |
| and in a damaged condition - the source rod was extended and broken. The |
| gauge was recovered by a passerby who thought the damaged gauge may be of |
| value and took it to a local equipment rental facility to ascertain the |
| value. He was warned of the radiation hazard but reportedly departed the |
| facility with the broken gauge. He evidently changed his mind and notified |
| the City of Arlington, who arrived and recovered the gauge. The gauge was |
| turned over to the Troxler Service Facility in Arlington where a leak test |
| was performed and indicated that the sealed sources were still intact. |
| However, the gauge would require repair before being placed back into |
| service. The Texas Licensee was notified of the recovery. The gauge is |
| being maintained by the Troxler facility until release by this agency for |
| repairs. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36840 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK REGION: 1 |NOTIFICATION DATE: 03/28/2000|
| UNIT: [1] [] [] STATE: NH |NOTIFICATION TIME: 15:21[EST]|
| RXTYPE: [1] W-4-LP |EVENT DATE: 03/28/2000|
+------------------------------------------------+EVENT TIME: 12:41[EST]|
| NRC NOTIFIED BY: MATTHEW ARSENAULT |LAST UPDATE DATE: 03/28/2000|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MICHELE EVANS R1 |
|10 CFR SECTION: | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PRIMARY COMPONENT COOLING WATER SYSTEM INOPERABLE DUE TO THE AREA |
| VENTILATION SYSTEM INCAPABLE OF PERFORMING ITS SAFETY FUNCTION |
| |
| "On 03/26/00 Seabrook Station entered Tech Spec (TS) 3.0.3 due to both |
| trains of the Primary Component Cooling Water (PCCW) system being declared |
| inoperable. Both trains of PCCW were declared inoperable because the PCCW |
| Area Ventilation System was determined to be incapable of performing its |
| intended function. |
| |
| "The PCCW system is a two train closed loop cooling system used to remove |
| heat from plant components during plant operation, plant cooldown and during |
| various phases of an accident. The PCCW pumps are located within the Primary |
| Auxiliary Building (PAB). The operation of the PCCW pumps is supported by |
| the PCCW Area Ventilation system. This ventilation system has redundant, |
| automatically controlled auxiliary supply fans and associated dampers to |
| ensure that the temperature in this area does not exceed design limits |
| should the normal PAB ventilation system fail. |
| |
| "During surveillance testing of the PCCW Area Ventilation system, an exhaust |
| damper (PAH-DP-357) failed to open as required. During a subsequent local |
| investigation by the Shift Manager and Unit Supervisor it was determined |
| that recent painting activities may have affected both PAB Exhaust Dampers |
| (PAH-DP-357 and PAH-DP-358). A subsequent test of PAH-DP-358 indicated that |
| it also failed to open as required. TS 3.0.3 was entered on 03/26/00 at |
| 0346. TS 3.0.3 was subsequently exited at 0425 on 03/26/00 after plant |
| personnel reestablished operability for PAH-DP-358. The subject dampers |
| automatically open to provide an exhaust flow path for the PCCW Pump Area |
| ventilation system which supports operation of the PCCW pumps. An initial |
| review of this condition concluded that a report pursuant to the |
| requirements of 10CFR50.72 was not required. A subsequent review of this |
| event determined that it is reportable pursuant to the requirements of |
| 10CFR50.72(b)(2)(iii) as a condition that alone could have prevented the |
| fulfillment of a safety function." |
| |
| The licensee will inform the NRC resident inspector. |
| |
| HOO Note: The event time was the time the licensee determined this |
| condition to be reportable to the NRC. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 36841 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 03/28/2000|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 18:54[EST]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 03/28/2000|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 10:30[EST]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 03/28/2000|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |RONALD GARDNER R3 |
| DOCKET: 0707002 |JOHN GREEVES NMSS |
+------------------------------------------------+CHARLES MILLER IRO |
| NRC NOTIFIED BY: ERIC SPAETH | |
| HQ OPS OFFICER: DICK JOLLIFFE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NBNL RESPONSE-BULLETIN | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NRC BULLETIN 91-01, 4 HOUR REPORT - |
| |
| At 1030 on 03/28/00, a box containing uranium oxide standard vials was |
| discovered under a workbench in building X-710 room 117, The applicable |
| Nuclear Criticality Safety Approval/Evaluation (NCSA/E-0710-011) does not |
| analyze storing uranium oxide vials in this area of the X-710 building. The |
| uranium oxide vials were transported to an area designated for storage of |
| such materials under applicable approved NCSAs. The material was |
| non-destructive assay (NDA) tested. The combined mass of all of the uranium |
| oxides in all the standard vials was 18 +/- 9 grams U-235 with an average |
| enrichment of 18 wt% U-235, |
| |
| SAFETY SIGNIFICANCE OF EVENTS: |
| The uranium oxide vials were stored at least two feet edge-to-edge from any |
| other fissile material. The combined mass of all of the uranium oxides in |
| all the standard vials was determined by NDA to be 18 +/- 9 grams U-235 with |
| an average enrichment of 18 wt% U-235. Due to the low mass and absence of |
| moderation, the safety significance is low. |
| |
| POTENTIAL CRITICALITY PATHWAYS INVOLVED [BRIEF SCENARIO(S) OF HOW |
| CRITICALITY COULD OCCUR]: |
| Additional mass and a spacing violation would have been required before a |
| criticality would be possible. Without moderation, much more than the safe |
| mass of 350 grams of U-235 would have to be present before a criticality |
| could be possible. |
| |
| CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, ETC.): |
| This was an unanalyzed condition. Although not specifically controlled, the |
| combined mass of all the uranium oxides in all the standard vials was less |
| than a safe mass, moderation was not present, and the uranium oxide vials |
| were spaced at least two feet from any other fissile material. |
| |
| ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDING PROCESS |
| LIMIT AND % WORST CASE OF CRITICAL MASS): |
| NDA shows the combined mass of all of the uranium oxides in all the standard |
| vials to be 18 +/- 9 grams of U-235 with an enrichment of 18 wt% U-235. The |
| material is in the form of dry oxides. For a spherical system at optimum |
| moderation, full water reflection, and 100 wt% enrichment, the safe mass is |
| 350 grams U-235. |
| |
| NUCLEAR CRITICALITY SAFEEY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION |
| OF THE FAILURES OR DEFICIENCIES: |
| The request failed to identify the presence of uranium oxide vials in the |
| room resulting in an unanalyzed condition. The uranium oxides are less than |
| a safe mass and other uranium bearing material was spaced at least two feet |
| edge-to-edge from the uranium oxides. |
| |
| CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS IMPLEMENTED: |
| The uranium oxide vials were removed from the X-710 room 117 under |
| applicable plant approved NCSAs. Total mass of material in X-710 room 117 is |
| currently less than 15 grams U-235. |
| |
| The NRC Resident Inspector and the site DOE Representative were notified. |
| |
| PTS-2000-038; PR-PTS-00-01697. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36842 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 03/28/2000|
| UNIT: [1] [] [] STATE: PA |NOTIFICATION TIME: 22:33[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 03/27/2000|
+------------------------------------------------+EVENT TIME: 15:30[EST]|
| NRC NOTIFIED BY: GRANT FERNSLER |LAST UPDATE DATE: 03/28/2000|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MICHELE EVANS R1 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - ESF ACTUATION OF REACTOR WATER CLEANUP SYSTEM DURING DRAINING EVOLUTIONS |
| - |
| |
| During the Unit 1 Refueling and Inspection Outage, the licensee determined |
| that the Reactor Water Cleanup System received an ESF Actuation signal |
| during draining evolutions. The potential for an ESF Actuation is identified |
| in the draining procedure, however after review, the licensee determined |
| that the actuation signal was not part of the planned evolution due to the |
| system not being properly removed from service. An actual isolation did not |
| occur due to the isolation valves being bypassed per the draining procedure. |
| |
| |
| This event has no effect on Unit 2 which is at 100% power. |
| |
| The licensee is investigating this event and determining corrective |
| actions. |
| |
| At 2030 on 03/28/00, while reviewing this event, the licensee determined |
| that this event is reportable to the NRC. This failure requires a four hour |
| ENS notification under 10CFR50.72(b)(2)(ii). |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36843 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 03/29/2000|
| UNIT: [1] [] [] STATE: PA |NOTIFICATION TIME: 02:38[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 03/29/2000|
+------------------------------------------------+EVENT TIME: 02:00[EST]|
| NRC NOTIFIED BY: GRANT FERNSLER |LAST UPDATE DATE: 03/29/2000|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MICHELE EVANS R1 |
|10 CFR SECTION: | |
|ADAS 50.72(b)(2)(i) DEG/UNANALYZED COND | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| EXCESSIVE LEAKAGE THROUGH CONTROL ROD DRIVE CHECK VALVES |
| |
| "During the Unit 1 Refuel and Inspection Outage, it has been determined that |
| the CRD check valves (CRD Seismic Island) exceeded the as-found minimum path |
| leakage limit of 508 ml/hr. This failure is a degraded condition found while |
| the plant is shutdown, and requires a 4 hour ENS notification under |
| 10CFR50.72(b)(2)(i)." |
| |
| The NRC resident inspector will be informed of this event by the licensee. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021