Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for March 24, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/23/2000 - 03/24/2000

                              ** EVENT NUMBERS **

36825  36826  36827  36828  36829  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36825       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 03/23/2000|
|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 13:11[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        03/23/2000|
+------------------------------------------------+EVENT TIME:        12:00[EST]|
| NRC NOTIFIED BY:  DENNIS CORNAX                |LAST UPDATE DATE:  03/23/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LOUIS MANNING        R1      |
|10 CFR SECTION:                                 |                             |
|ADAS 50.72(b)(2)(i)      DEG/UNANALYZED COND    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| C-3 DEFECTS DETECTED DURING EDDY CURRENT INSPECTION OF STEAM GENERATORS      |
|                                                                              |
| Indian Point 2 is conducting eddy current testing of 100% of the steam       |
| generator (SG) tubes.  With about 90% of the inspection complete, SG-21 and  |
| SG-24 tubes have defects in greater than 1% of the tubes inspected.  SG-22   |
| and SG-23 have defects in much less than 1% of the tubes inspected.  The     |
| majority of the defects are at the support plate intersections and in row 2  |
| U-bends.  There are 41 indications in SG-21, 40 at the support plate and 1   |
| in the U-bend.  There are 39 indications in SG-24, 36 at the support plate   |
| and 3 in the U-bend.  In accordance with Technical Specification 4.13, these |
| defects result in a C-3 classification.  The testing will continue until     |
| 100% of the tubes are inspected.                                             |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36826       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY                   REGION:  2  |NOTIFICATION DATE: 03/23/2000|
|    UNIT:  [1] [] []                 STATE:  AL |NOTIFICATION TIME: 13:17[EST]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        03/23/2000|
+------------------------------------------------+EVENT TIME:        08:30[CST]|
| NRC NOTIFIED BY:  WEST CUMBEE                  |LAST UPDATE DATE:  03/23/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THREE FUEL ASSEMBLIES DETERMINED TO BE IN WRONG POSITIONS IN THE SPENT FUEL  |
| POOL                                                                         |
|                                                                              |
| Unit 1 personnel determined that three fuel assemblies, in the Unit 1 Spent  |
| Fuel Pool (SFP), were in positions inconsistent with the Technical           |
| Specifications (TS).  Preliminary assessment indicates that the Keff limit   |
| of 0.95 (TS 3.7.15) for the SFP would have still been met.  This condition   |
| existed for ten days, since the last Unit 1 core offload.  The assemblies    |
| have been returned to the positions allowed by TS.  An investigation is in   |
| progress to  determine the cause of this event and to determine if the Keff  |
| limit was exceeded.  There will be a 30 day written report submitted.        |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36827       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE: 03/23/2000|
|LICENSEE:  NDC                                  |NOTIFICATION TIME: 16:46[EST]|
|    CITY:  IRWINDALE                REGION:  4  |EVENT DATE:        03/21/2000|
|  COUNTY:                            STATE:  CA |EVENT TIME:        06:30[PST]|
|LICENSE#:  145-19                AGREEMENT:  Y  |LAST UPDATE DATE:  03/23/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LAWRENCE YANDELL     R4      |
|                                                |LARRY CAMPER         NMSS    |
+------------------------------------------------+FRANK CONGEL         IRO     |
| NRC NOTIFIED BY:  DONALD BUNN                  |MATT ROBERTS         DOT     |
|  HQ OPS OFFICER:  FANGIE JONES                 |JOHN WILLIAMS        DOE     |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|NTRA                     TRANSPORTATION EVENT   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE/TRANSPORTATION EVENT INVOLVING A BURNED FEDERAL EXPRESS      |
| TRUCK CARRYING A GAUGE WITH A SMALL SOURCE IN IT                             |
|                                                                              |
| On 3/21/00 at about 6:30 AM in Oxnard CA, a Federal Express truck burned due |
| to an unknown cause.  It was discovered today, 3/23/00, that a thickness     |
| gauge from NDC of Irwindale, CA was on the truck.  The gauge contains a      |
| special form source of Curium-244, 100 mCi.  The source is thought to be     |
| able to survive the fire and is being sought.  Dr. Roy Parker, the Federal   |
| Express Safety Officer, is on the scene and following up on the incident.    |
|                                                                              |
| The National Response Center report number is 523952.                        |
|                                                                              |
| (Call the HOO for contact numbers)                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36828       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 03/23/2000|
|    UNIT:  [] [2] []                 STATE:  GA |NOTIFICATION TIME: 23:27[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/23/2000|
+------------------------------------------------+EVENT TIME:        21:40[EST]|
| NRC NOTIFIED BY:  BRUCE BUTLER                 |LAST UPDATE DATE:  03/23/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     A          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FULL REACTOR SCRAM SIGNALS GENERATED DURING TESTING WHILE REACTOR IS         |
| SHUTDOWN                                                                     |
|                                                                              |
| With Unit 2 in a refueling outage, control room operators were performing a  |
| Reactor Protection System scram discharge volume (SDV) high water level      |
| bypass switch (rod block) functional test.  During performance of the test,  |
| control room operators placed the SDV high water level bypass switch         |
| #2C71-54 in the bypass position and the reactor mode switch in the shutdown  |
| position.  This action caused the generation of a full reactor scram signal. |
| The Control Rod Drive System had already been deenergized and all control    |
| rods were already fully inserted into the reactor core.                      |
|                                                                              |
| Control room operators reset the reactor scram signal to normal and placed   |
| the bypass switch in the normal position in accordance with the test         |
| procedure.  However, the bypass switch was placed in the normal position     |
| before the SDV had time to drain down.  With the SDV water level above the   |
| high level alarm setpoint, a second full reactor scram signal was            |
| generated.                                                                   |
|                                                                              |
| The licensee restored all systems to normal and is investigating this        |
| situation, including reviewing the test procedure.                           |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36829       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/24/2000|
|    UNIT:  [1] [] []                 STATE:  PA |NOTIFICATION TIME: 05:56[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/24/2000|
+------------------------------------------------+EVENT TIME:        04:45[EST]|
| NRC NOTIFIED BY:  DAVE WALSH                   |LAST UPDATE DATE:  03/24/2000|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LOUIS MANNING        R1      |
|10 CFR SECTION:                                 |                             |
|ADAS 50.72(b)(2)(i)      DEG/UNANALYZED COND    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - 'C' INBOARD MAIN STEAM ISOLATION VALVE FAILED ITS LOCAL LEAK RATE TEST -   |
|                                                                              |
| During the performance of a local leak rate test of the 'C' main steam       |
| isolation valves (MSIVs) with Unit 1 in a refueling outage, the inboard MSIV |
| #HV141-F022C was unable to hold pressure.  This constitutes a failure of the |
| maximum path leak rate required by Tech Spec 3.6.1.3.                        |
|                                                                              |
| This condition constitutes a degraded condition of a principle safety        |
| barrier found while Unit 1 was shutdown.  No other adverse conditions were   |
| identified.                                                                  |
|                                                                              |
| Unit 1 remains safely shutdown and the licensee is conducting an             |
| investigation to determine the cause of the failure.                         |
|                                                                              |
| The licensee plans to notify the NRC Resident Inspector.                     |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021