Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for February 9, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           02/08/2000 - 02/09/2000

                              ** EVENT NUMBERS **

36670  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36670       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 02/08/2000|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 07:14[EST]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        02/08/2000|
+------------------------------------------------+EVENT TIME:        03:33[CST]|
| NRC NOTIFIED BY:  STEVE CHRISTIAN              |LAST UPDATE DATE:  02/08/2000|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MICHAEL PARKER       R3      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ESF ACTUATION - OUTBOARD RECIRC SAMPLE VALVE CLOSED                          |
|                                                                              |
| During performance of Main Steam Isolation Valve Functional Test             |
| 0255-07-IA-2, the outboard recirc sample valve CV-2791 closed due to         |
| activation of a Group I isolation signal.  The procedure step de-energized   |
| the DC power to verify that the outboard main steam isolation valves would   |
| remain open with AC power.  However, the procedure did not recognize that    |
| the other Group I outboard valves would close when DC power was              |
| interrupted.                                                                 |
|                                                                              |
| The licensee will notify the NRC resident inspector.                         |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021