The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for February 8, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
02/07/2000 - 02/08/2000
** EVENT NUMBERS **
36666 36667 36668 36669
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36666 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO REGION: 3 |NOTIFICATION DATE: 02/07/2000|
| UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 03:11[EST]|
| RXTYPE: [1] GE-3 |EVENT DATE: 02/07/2000|
+------------------------------------------------+EVENT TIME: 00:55[CST]|
| NRC NOTIFIED BY: KEVIN PEDERSON |LAST UPDATE DATE: 02/07/2000|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |TONY VEGEL R3 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| ESF ACTUATION - RECIRC SAMPLE ISOLATION VALVES |
| |
| During the performance of standby liquid control refueling tests, a signal |
| is sent to the reactor water cleanup isolation valves and the recirc sample |
| valves. The procedure addresses the RWCU valves, but not the recirc sample |
| valves. Since the outboard sample valve was secured (tagged) open, it |
| unexpectedly closed upon initiation of the standby liquid control system. |
| |
| The valves were returned to their pre-test positions. |
| |
| The licensee will notify the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36667 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 02/07/2000|
| UNIT: [1] [2] [] STATE: IL |NOTIFICATION TIME: 04:28[EST]|
| RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 02/07/2000|
+------------------------------------------------+EVENT TIME: 02:40[CST]|
| NRC NOTIFIED BY: DAVE KLIMECK |LAST UPDATE DATE: 02/07/2000|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |TONY VEGEL R3 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| Minimum security personnel staffing requirements not met. Immediate |
| compensatory actions taken upon discovery. The licensee will notify the |
| NRC resident inspector. Additional details of this event may be obtained by |
| contacting the NRC operations officer. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Hospital |Event Number: 36668 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: ST. ANTHONY MEDICAL CENTER |NOTIFICATION DATE: 02/07/2000|
|LICENSEE: ST. ANTHONY MEDICAL CENTER |NOTIFICATION TIME: 17:14[EST]|
| CITY: CROWN POINT REGION: 3 |EVENT DATE: 02/07/2000|
| COUNTY: STATE: IN |EVENT TIME: 09:00[CST]|
|LICENSE#: 13-15933-01 AGREEMENT: N |LAST UPDATE DATE: 02/07/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MICHAEL PARKER R3 |
| |JOE HOLONICH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: RAM BASAVATIA | |
| HQ OPS OFFICER: BOB STRANSKY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|LADM 35.33(a) MED MISADMINISTRATION | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| MEDICAL MISADMINISTRATION |
| |
| A patient, who was prescribed a dose of 100 �Ci I-131 for a thyroid scan, |
| was administered a dose of 500 �Ci I-131. The patient was released before |
| the error was discovered. The patient has since been contacted and is |
| returning to the hospital to be administered KI (potassium iodide) to limit |
| the uptake of radioiodine in the thyroid. The licensee radiation safety |
| officer did not provide an estimate of the thyroid dose, but stated that |
| whole body dose would be approximately 31 rads without administration of |
| KI. |
| |
| The patient's attending physician will be informed of this |
| misadministration. The licensee has already contacted NRC Region III (T. |
| Go). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36669 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 02/07/2000|
| UNIT: [] [2] [] STATE: AL |NOTIFICATION TIME: 18:56[EST]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 02/07/2000|
+------------------------------------------------+EVENT TIME: 14:30[CST]|
| NRC NOTIFIED BY: BILL ARNES |LAST UPDATE DATE: 02/07/2000|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |KERRY LANDIS R2 |
|10 CFR SECTION: | |
|AINA 50.72(b)(2)(iii)(A) POT UNABLE TO SAFE SD | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| POTENTIAL ENTRY INTO TECHNICAL SPECIFICATION 3.0.5 |
| |
| While the 'A' emergency diesel generator (EDG) was out of service for |
| maintenance, the licensee determined that the 'B' service water booster pump |
| had previously been removed from service due to its breaker repeatedly |
| tripping on overcurrent. The 'B' service water booster pump may be attendant |
| equipment for the 'B' service water train. The licensee is currently |
| performing an attendant equipment evaluation of the 'B' service water |
| booster pump. This condition may have required that the unit enter Technical |
| Specification 3.0.5. |
| |
| The NRC resident inspector has been informed of this event by the licensee. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021