Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for February 1, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           01/31/2000 - 02/01/2000

                              ** EVENT NUMBERS **

36640  36642  36643  36644  36645  36646  36647  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36640       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS           REGION:  1  |NOTIFICATION DATE: 01/29/2000|
|    UNIT:  [1] [] []                 STATE:  MD |NOTIFICATION TIME: 00:45[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        01/28/2000|
+------------------------------------------------+EVENT TIME:        22:00[EST]|
| NRC NOTIFIED BY:  GETZ                         |LAST UPDATE DATE:  01/31/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN ROGGE           R1      |
|10 CFR SECTION:                                 |                             |
|AINC 50.72(b)(2)(iii)(C) POT UNCNTRL RAD REL    |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ECCS VENT SYSTEM FAILED SURVEILLANCE DUE TO PROBLEMS WITH THE CHARCOAL       |
| FILTERS.                                                                     |
|                                                                              |
| UPON THE COMPLETION OF MAINTENANCE PERFORMED ON THE 11 AND 12 ECCS PUMP ROOM |
| VENT FANS, IT WAS DETERMINED THAT THE CHARCOAL FILTERS DID NOT SEAT PROPERLY |
| DURING A CHARCOAL TEST (STPM-547-1) RESULTING IN THE TEST CRITERIA NOT BEING |
| MET.  SEVERAL LOOSE NUTS WERE DISCOVERED ON THE CHARCOAL TRAY HOLD-DOWN      |
| FASTENERS.  THE NUTS WERE TIGHTENED, AND THE SURVEILLANCE WAS PERFORMED      |
| SATISFACTORILY.  THE LICENSEE IS INVESTIGATING WHY THE NUTS WERE LOOSE SINCE |
| THE FILTERS WERE NOT INVOLVED IN MAINTENANCE PERFORMED.                      |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED BY THE LICENSEE.                     |
|                                                                              |
| *************** UPDATE AT 0335 ON 01/31/00 FROM LEO GREGORY GETZ TO LEIGH    |
| TROCINE ***************                                                      |
|                                                                              |
| The licensee called to change its internal event report number and to        |
| provide the following updated information.  In an effort to check for a      |
| common mode problem, the licensee checked the Unit 2 charcoal filters on     |
| 01/29/00.  They all tested satisfactorily.                                   |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations        |
| officer notified the R1DO (Rogge).                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36642       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: KEWAUNEE                 REGION:  3  |NOTIFICATION DATE: 01/31/2000|
|    UNIT:  [1] [] []                 STATE:  WI |NOTIFICATION TIME: 10:10[EST]|
|   RXTYPE: [1] W-2-LP                           |EVENT DATE:        01/31/2000|
+------------------------------------------------+EVENT TIME:        08:15[CST]|
| NRC NOTIFIED BY:  GARY HARRINGTON              |LAST UPDATE DATE:  01/31/2000|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |TONY VEGEL           R3      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       97       Power Operation  |97       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY EVENT                                                               |
|                                                                              |
| Unescorted access granted improperly to former plant employee. The licensee  |
| notified the NRC resident inspector. Contact the NRC Operations Center for   |
| additional details.                                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36643       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  DEPARTMENT OF THE NAVY               |NOTIFICATION DATE: 01/31/2000|
|LICENSEE:  DEPARTMENT OF THE NAVY               |NOTIFICATION TIME: 12:34[EST]|
|    CITY:  CHERRY POINT             REGION:  2  |EVENT DATE:        01/20/2000|
|  COUNTY:                            STATE:  NC |EVENT TIME:             [EST]|
|LICENSE#:  45TAC23645TAC         AGREEMENT:  Y  |LAST UPDATE DATE:  01/31/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CAUDLE JULIAN        R2      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+FRANK CONGEL         IRO     |
| NRC NOTIFIED BY:  HIGGINS                      |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| U.S. NAVY REPORTED MISSING DROGUE LIGHTS AT THE MARINE CORP AIR STATION IN   |
| CHERRY POINT, N.C.                                                           |
|                                                                              |
| A DROGUE LIGHT (USED DURING NIGHT AIRCRAFT REFUELING) IS A BASKET ASSEMBLY   |
| CONTAINING 6 ISOLITES WHICH CONTAIN 1 CURIE OF TRITIUM EACH FOR A TOTAL OF 6 |
| CURIES.  THERE WAS A SECOND BASKET ASSEMBLY CONTAINING 5 ISOLITES WHICH ALSO |
| CONTAINED 1 CURIE EACH OF TRITIUM AND A 6th ISOLITE WHICH CONTAINED 25       |
| MILLICURIES OF KRYPTON-85.  THEREFORE, THERE IS A TOTAL ACTIVITY OF 11       |
| CURIES OF TRITIUM AND 25 MILLICURIES OF KRYPTON-85 MISSING.  THEY HAVE BEEN  |
| SEARCHING FOR THESE SOURCES SINCE 01/20/00 WITH NO SUCCESS.  ON 01/28/00, IT |
| WAS DETERMINED THAT THIS WAS A REPORTABLE EVENT.  THEY BELIEVE, HOWEVER,     |
| THAT THESE SOURCES WERE NOT STOLEN OR LOST BUT WERE RETURNED TO THE NAVY     |
| SUPPLY SYSTEM AFTER THEY HAD BEEN REMOVED ON 12/14/99. THEY ARE HAVING A     |
| NAVY JAG INVESTIGATION ON THIS INCIDENT.                                     |
|                                                                              |
| CALL THE NRC OPERATIONS OFFICER FOR A LICENSEE CONTACT TELEPHONE NUMBER.     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36644       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HADDAM NECK              REGION:  1  |NOTIFICATION DATE: 01/31/2000|
|    UNIT:  [1] [] []                 STATE:  CT |NOTIFICATION TIME: 13:22[EST]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        01/31/2000|
+------------------------------------------------+EVENT TIME:        11:45[EST]|
| NRC NOTIFIED BY:  CAMPBELL                     |LAST UPDATE DATE:  01/31/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |TONY DIMITRIADIS     R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| NOTIFICATION OF AN OIL SPILL TO THE STATE OF CONNECTICUT DEPARTMENT OF       |
| ENVIRONMENTAL PROTECTION, NATIONAL RESPONSE CENTER, AND THE U.S. COAST       |
| GUARD.                                                                       |
|                                                                              |
| THE LICENSEE HAD A MOTOR OIL SPILL OF ~1/2 CUP TO A STORM DRAIN SYSTEM WHICH |
| CONNECTS TO THE CONNECTICUT RIVER.  THE SPILL IS BEING CLEANED UP, AND       |
| OFFSITE NOTIFICATIONS WERE MADE.                                             |
|                                                                              |
| THE LICENSEE HAS NO NRC RESIDENT INSPECTOR                                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36645       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: QUAD CITIES              REGION:  3  |NOTIFICATION DATE: 01/31/2000|
|    UNIT:  [] [2] []                 STATE:  IL |NOTIFICATION TIME: 14:18[EST]|
|   RXTYPE: [1] GE-3,[2] GE-3                    |EVENT DATE:        01/31/2000|
+------------------------------------------------+EVENT TIME:        10:05[CST]|
| NRC NOTIFIED BY:  MACLENNAN                    |LAST UPDATE DATE:  01/31/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |TONY VEGEL           R3      |
|10 CFR SECTION:                                 |DAVID MATTHEWS       NRR     |
|NINF                     INFORMATION ONLY       |FRANK CONGEL         IRO     |
|                                                |MINDY LANDAU         PAO     |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| VOLUNTARY REPORT OF A MEDIA RESPONSE RELATED TO CALL-OUT OF LOCAL FIRE       |
| DEPARTMENT                                                                   |
|                                                                              |
| At 1005 hours (CST) on January 31, 2000, the control room received a report  |
| of a small explosion in the Unit 2 pipeway between the main steam isolation  |
| valve (MSIV) room and the low-pressure heater bay.  Control room personnel,  |
| in accordance with station procedures, notified the local (Cordova, IL) fire |
| department of an explosion and possible fire.  There were no personnel       |
| injuries, no equipment damage, and no fire.                                  |
|                                                                              |
| As a result of the call to the fire department, local law enforcement        |
| agencies and two television stations responded to the site.  The two         |
| television stations were KWQC (TV-6) (NBC) and WQAD (TV-8) (ABC).  For a     |
| period of time, the state road in the vicinity of the plant was closed by    |
| law enforcement agencies.                                                    |
|                                                                              |
| The cause of the report to the control room was a very loud, sudden noise    |
| that resulted when a nylon bag containing small oxygen and acetylene bottles |
| and hoses was opened.  The sound was most likely the result of the ignition  |
| of a small amount of oxygen and acetylene trapped in the bag.   Although no  |
| notification was made or planned for local media or law enforcement support, |
| personnel from both of these areas were dispatched to the site.  There were  |
| no injuries or fire.  No equipment was affected.  This notification is being |
| made voluntarily.                                                            |
|                                                                              |
| The NRC Resident Inspector was notified, and there will be no media          |
| releases.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36646       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  PENNSYLVANIA STATE UNIVERSITY        |NOTIFICATION DATE: 01/31/2000|
|LICENSEE:  PENNSYLVANIA STATE UNIVERSITY        |NOTIFICATION TIME: 16:52[EST]|
|    CITY:  UNIVERSITY PARK          REGION:  1  |EVENT DATE:        01/31/2000|
|  COUNTY:  CENTRE                    STATE:  PA |EVENT TIME:        16:00[EST]|
|LICENSE#:  3718504               AGREEMENT:  N  |LAST UPDATE DATE:  01/31/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |TONY DIMITRIADIS     R1      |
|                                                |LARRY CAMPER         NMSS    |
+------------------------------------------------+FRANK CONGEL         IRO     |
| NRC NOTIFIED BY:  BOELDT                       |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REPORT OF A STOLEN TRITIUM EXIT SIGN                                         |
|                                                                              |
| THE PENNSYLVANIA STATE UNIVERSITY REPORTED THAT A TRITIUM EXIT SIGN WAS      |
| STOLEN FROM A BUILDING ON THEIR NEW KENSINGTON CAMPUS NEAR PITTSBURGH, PA,   |
| SOME TIME BETWEEN 01/28/00 AND 01/31/00.  THE SIGN CONTAINS APPROXIMATELY 19 |
| CURIES OF TRITIUM.  THEY ARE CONTINUING THE SEARCH AND PLAN TO NOTIFY THE    |
| LOCAL AUTHORITIES.                                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36647       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK              REGION:  1  |NOTIFICATION DATE: 01/31/2000|
|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 17:12[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        01/31/2000|
+------------------------------------------------+EVENT TIME:        17:00[EST]|
| NRC NOTIFIED BY:  ALLEN                        |LAST UPDATE DATE:  01/31/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |TONY DIMITRIADIS     R1      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       60       Power Operation  |60       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HIGH PRESSURE COOLANT INJECTION (HPCI) SYSTEM DECLARED INOPERABLE, THEREBY   |
| ENTERING THE PLANT INTO A 7-DAY LCO ACTION STATEMENT                         |
|                                                                              |
| DURING A HPCI SURVEILLANCE TEST, HPCI WAS DECLARED INOPERABLE DUE TO FLOW    |
| AND SPEED ANOMALIES.  THIS CONDITION ENTERS THE PLANT INTO A 7-DAY LCO TO    |
| RETURN HPCI TO AN OPERABLE CONDITION OR BE IN COLD SHUTDOWN WITHIN 24 HOURS. |
| THESE ANOMALIES HAVE OCCURRED IN THE PAST SEVERAL MONTHS, WHICH IS THE       |
| REASON FOR THE INCREASED SURVEILLANCE TESTING.  DURING TODAY'S SURVEILLANCE, |
| THE PUMP SPEED JUMPED FOR NO APPARENT REASON FOR <1 MIN BEFORE RETURNING TO  |
| NORMAL SPEED.  THIS IS THE FIRST TIME THEY HAVE SEEN THIS ANOMALY FOR 2      |
| MONTHS.  THEY HAVE NOT DETERMINED THE CAUSE FOR THE INCREASE IN PRESSURE AND |
| SPEED, BUT THEY WILL BE TROUBLESHOOTING THE PUMP.                            |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED BY THE LICENSEE.                 |
+------------------------------------------------------------------------------+