The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for January 27, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           01/26/2000 - 01/27/2000

                              ** EVENT NUMBERS **

36620  36623  36624  36625  36626  36627  36628  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36620       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 01/24/2000|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 22:37[EST]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        01/24/2000|
+------------------------------------------------+EVENT TIME:        22:15[EST]|
| NRC NOTIFIED BY:  HENRY MANOS                  |LAST UPDATE DATE:  01/26/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |KERRY LANDIS         R2      |
|10 CFR SECTION:                                 |                             |
|AENS 50.72(b)(1)(v)      ENS INOPERABLE         |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MORE THAN 25% OF THE OFFSITE WARNING SIRENS LOST DUE TO ICE STORMS           |
|                                                                              |
| The licensee reported the loss of more than 25% of the offsite warning       |
| sirens due to ice storms passing through the local area.  The licensee will  |
| be contacting the power suppliers of the sirens to take action to recover    |
| them.                                                                        |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| * * * UPDATE AT 1315 EST ON 1/26/00 BY BLAIR WILSON TO FANGIE JONES * * *    |
|                                                                              |
| Greater than 75 % of the emergency sirens (86 %) have been restored to       |
| service, this is the last update as the minimum number operable is met.  The |
| NRC Resident Inspector has been notified.                                    |
|                                                                              |
| The R2DO (Caudle Julian) has been informed.                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36623       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: ROBINSON                 REGION:  2  |NOTIFICATION DATE: 01/25/2000|
|    UNIT:  [2] [] []                 STATE:  SC |NOTIFICATION TIME: 08:45[EST]|
|   RXTYPE: [2] W-3-LP                           |EVENT DATE:        01/25/2000|
+------------------------------------------------+EVENT TIME:        07:50[EST]|
| NRC NOTIFIED BY:  BAUCOM                       |LAST UPDATE DATE:  01/26/2000|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |KERRY LANDIS         R2      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF AC POWER TO 23 OF 45 EMERGENCY SIRENS DUE TO SNOW AND ICE.           |
|                                                                              |
| Due to recent accumulation of snow and ice, sporadic power outages have      |
| occurred in the area.  This has resulted in "loss of AC power" indications   |
| for 23/45 Public Warning Sirens per their remote siren monitoring system.    |
| This is considered a loss of off-site response capability .  Actions are     |
| being initiated to restore operability.  Local surrounding counties will be  |
| notified of this condition.                                                  |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
|                                                                              |
| * * * UPDATE AT 1509 EST ON 1/25/00 BY PETER YANDOW TO FANGIE JONES * * *    |
|                                                                              |
| Power outages continue to be a problem in the Darlington, Lee, and           |
| Chesterfield counties affecting the public warning sirens.  A total of 31 of |
| 45 have been out-of-service, but restorations have brought the number down   |
| to 26 of 45 out-of-service.  The NRC Resident Inspector has been notified.   |
|                                                                              |
| The R2DO (Caudle Julian) has been informed.                                  |
|                                                                              |
| * * * UPDATE AT 1533 EST ON 1/26/00 BY PETER YANDOW TO FANGIE JONES * * *    |
|                                                                              |
| Greater than 75 % of the emergency sirens (only 9 of 45 remain               |
| out-of-service) have been restored to service, this is the last update as    |
| the minimum number operable is met.  The NRC Resident Inspector has been     |
| notified.                                                                    |
|                                                                              |
| The R2DO (Caudle Julian) has been informed.                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36624       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 01/26/2000|
|    UNIT:  [] [2] []                 STATE:  TN |NOTIFICATION TIME: 04:29[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        01/26/2000|
+------------------------------------------------+EVENT TIME:        00:39[EST]|
| NRC NOTIFIED BY:  JEFF EPPERSON                |LAST UPDATE DATE:  01/26/2000|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 2 ENTERED TECH SPEC 3.0.3 DUE TO BOTH TRAINS SAFETY INJECTION           |
| INOPERABLE                                                                   |
|                                                                              |
| "AT 0039 EST ON 1/26/2000 BOTH TRAINS OF THE SAFETY INJECTION PUMPS (SIPs)   |
| OF SEQUOYAH UNIT 2 WERE RENDERED INOPERABLE.  THE '2A' SAFETY INJECTION PUMP |
| AND ITS ROOM COOLER WERE TAGGED OUT UNDER THE SITES TAGOUT PROCEDURE FOR     |
| MAINTENANCE.  EITHER OF THESE COMPONENTS [SI PUMP OR ITS ASSOCIATED ROOM     |
| COOLER] BEING TAGGED MADE THE PUMP INOPERABLE.  WHILE THE '2A' SI PUMP WAS   |
| INOPERABLE, MAINTENANCE WORKERS MISTAKENLY DRAINED THE OIL  FROM THE '2B'    |
| SAFETY INJECTION PUMP MOTOR BEARING FOR A PERIOD OF TIME WHICH MADE IT       |
| INOPERABLE AND UNAVAILABLE.  THIS OIL CHANGING EVOLUTION REQUIRED            |
| APPROXIMATELY 30 MINUTES TO ACCOMPLISH.  THE SIMULANTEOUS INOPERABILITY OF   |
| BOTH UNIT 2 SI PUMPS REQUIRED ENTRY INTO TECHNICAL SPECIFICATION LCO 3.0.3   |
| ACTION.  IMMEDIATE STEPS WERE INITIATED TO RESTORE OPERABILITY TO '2B' SI    |
| PUMP.  AT 0316 EST ON 1/26/2000 THE '2B' SI PUMP WAS DECLARED OPERABLE WHEN  |
| THE PUMP WAS SUCCESSFULLY RUN.  LCO 3.0.3 ACTION WAS THEN EXITED.  AN        |
| INVESTIGATION INTO THE CAUSE OF THIS EVENT WILL BE CONDUCTED."               |
|                                                                              |
| MAINTENANCE WORKERS WERE TAKING A SAMPLE OF THE BEARING OIL FOR ANALYSIS     |
| WHICH IS USUALLY ACCOMPLISHED THROUGH DRAINING.                              |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WILL BE INFORMED.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36625       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 01/26/2000|
|    UNIT:  [1] [] []                 STATE:  GA |NOTIFICATION TIME: 07:42[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        01/26/2000|
+------------------------------------------------+EVENT TIME:        06:48[EST]|
| NRC NOTIFIED BY:  FRANK GORLEY                 |LAST UPDATE DATE:  01/26/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |WILLIAM BATEMAN      NRR     |
|ACCS 50.72(b)(1)(iv)     ECCS INJECTION         |FRANK CONGEL         IRO     |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 1 EXPERIENCED AN AUTOMATIC REACTOR SCRAM ON LOW REACTOR VESSEL WATER    |
| LEVEL DUE TO A FEEDWATER (FW) CONTROL FAILURE                                |
|                                                                              |
| AT APPROXIMATELY 0648 EST ON 1/26/2000 CONTROL ROOM OPERATORS RESPONDED TO A |
| FEEDWATER CONTROL FAILURE ALARM.  WHILE INVESTIGATING, FEEDWATER PUMP SPEED  |
| DECREASED CAUSING REACTOR VESSEL WATER LEVEL (RVWL)TO DROP FROM ITS NORMAL   |
| OPERATING LEVEL OF 37.5" TO APPROXIMATELY -45".  AT 0"  AN AUTOMATIC REACTOR |
| SCRAM AND GROUP 2 ENGINEERED SAFEGUARDS FEATURES (ESF) ACTUATION OCCURRED,   |
| AS EXPECTED.  ALL CONTROL RODS FULLY INSERTED.  AT -38" BOTH THE HIGH        |
| PRESSURE COOLANT INJECTION (HPCI) AND REACTOR CORE ISOLATION COOLING (RCIC)  |
| SYSTEM RECEIVED A START SIGNAL.  HPCI INJECTED UNTIL THE HPCI PUMP TRIPPED   |
| AT ITS RVWL SETPOINT OF 51.5".  THE FW PUMPS TRIPPED AT 58" WITH RVWL SWELL  |
| CAUSING LEVEL TO REACH 100".  FOLLOWING THE LEVEL TRANSIENT OPERATORS HAD    |
| DIFFICULTY IN ESTABLISHING THE LO-LO SET RANGE FOR PRESSURE CONTROL.         |
| NORMALLY, ONE OF THE FOUR SAFETY RELIEF VALVES USED FOR PRESSURE CONTROL,    |
| i.e.,  "H", "A", "G", OR "C" SRV, IS OPENED ELECTRICALLY FROM THE CONTROL    |
| ROOM WHICH THEN ESTABLISHES THE LOWER PRESSURE CONTROL.  TEN OF THE ELEVEN   |
| SRVs FAILED TO OPEN IN RESPONSE TO CONTROL ROOM SWITCH POSITIONING.  THE     |
| LAST SRV ATTEMPTED, THE "B" SRV, OPENED.  UNIT 1 IS CURRENTLY STABLE IN HOT  |
| SHUTDOWN REJECTING DECAY HEAT TO THE TORUS WITH BOTH TRAINS OF SUPPRESSION   |
| POOL COOLING IN SERVICE.  EFFORTS ARE UNDERWAY TO RESTORE THE MAIN CONDENSER |
| AS A HEAT SINK.  UNIT 1 INTENDS TO COOLDOWN TO INVESTIGATE AND RESOLVE THE   |
| PROBLEM WITH THE SRVs.  THERE IS NO INDICATION THAT THE SRV MECHANICAL       |
| SAFETY OR ADS FUNCTION IS IMPAIRED AT THIS TIME.  DURING THE TRANSIENT,      |
| REACTOR COOLANT SYSTEM (RCS) TEMP AND PRESSURE DECREASED FROM THEIR NORMAL   |
| AT POWER VALUES OF 532 DEGREES F AND 1035 PSIG TO AN OBSERVED MINIMUM OF 480 |
| DEGREES F AND 871 PSIG.  BOTH ARE CURRENTLY  AT 510 DEGREES F AND 977 PSIG.  |
| THERE IS NO INDICATION THAT THE 100 DEGREES F/ HR COOLDOWN RATE WAS          |
| EXCEEDED.                                                                    |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36626       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MILLSTONE                REGION:  1  |NOTIFICATION DATE: 01/26/2000|
|    UNIT:  [1] [2] [3]               STATE:  CT |NOTIFICATION TIME: 11:06[EST]|
|   RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP           |EVENT DATE:        01/26/2000|
+------------------------------------------------+EVENT TIME:        09:47[EST]|
| NRC NOTIFIED BY:  STEVE LAWHEAD                |LAST UPDATE DATE:  01/26/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN ROGGE           R1      |
|10 CFR SECTION:                                 |WILLIAM BATEMAN      NRR     |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |FRANK CONGEL         IRO     |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO STATE/LOCAL AGENCIES INVOLVING ERRONEOUS EMERGENCY   |
|                                                                              |
| "At 0947 on January 26, 2000 a notification to offsite emergency response    |
| agencies was made in error. The notification indicated that a General        |
| Emergency had been declared at Millstone. No emergency conditions currently  |
| exists at the site. The notification occurred during testing of the primary  |
| notification system. The cause of the condition is being investigated at     |
| this time. Backup means of notification is available in the event that a     |
| bonafide emergency condition arises prior to the restoration of the primary  |
| notification system.                                                         |
|                                                                              |
| "Retractions of the event notification were issued to appropriate State and  |
| local agencies. Millstone emergency management personnel have also been in   |
| contact with representatives of these agencies."                             |
|                                                                              |
| The licensee informed the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36627       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  SOLIDSTATE CONTROLS, INC.            |NOTIFICATION DATE: 01/26/2000|
|LICENSEE:  SOLIDSTATE CONTROLS, INC.            |NOTIFICATION TIME: 16:11[EST]|
|    CITY:  COLUMBUS                 REGION:  3  |EVENT DATE:        01/21/2000|
|  COUNTY:                            STATE:  OH |EVENT TIME:             [EST]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  01/26/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MONTE PHILLIPS       R3      |
|                                                |JOHN ROGGE           R1      |
+------------------------------------------------+CAUDLE JULIAN        R2      |
| NRC NOTIFIED BY:  W. G. HAMPTON                |GAIL GOOD            R4      |
|  HQ OPS OFFICER:  FANGIE JONES                 |VERN HODGE (fax)     NRR     |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 10 CFR 21 - POTENTIAL DEFECT INVOLVING STATIC SWITCH CONTROL ASSEMBLY AND    |
| REGULATED RECTIFIER CONTROL ASSEMBLY USED IN AN UNINTERRUPTIBLE POWER        |
| SYSTEM                                                                       |
|                                                                              |
| This reports a potential for a defect in Static Switch Control assemblies    |
| and Regulated Rectifier Control assemblies used in Uninterruptible Power     |
| Systems manufactured under the Solidstate Controls, Inc., 10CFR50 Appendix B |
| Program.                                                                     |
|                                                                              |
| Each of the plants has been notified of this report and requested to return  |
| the affected assemblies for replacement.  The following plants have affected |
| components:  Indian Point 2, Catawba, Oconee, Arkansas Nuclear One,          |
| Waterford 3, Crystal River, Diablo Canyon, Sequoyah, and Surry.              |
|                                                                              |
| The problem is associated with a component part - Unijunction Transistor,    |
| part number 03-650007-00, that has been found to sometimes cause random,     |
| sporadic transfers of the static switch due to a higher level of sensitivity |
| to noise spikes on the input line or cause the regulated rectifier to output |
| a higher DC voltage.  This increase in sensitivity will not cause the system |
| to drop power to the load, if the alternate source is not available the      |
| static switch will not transfer, continuing to protect the load.             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36628       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  METROPOLITAN DISTRICT                |NOTIFICATION DATE: 01/26/2000|
|LICENSEE:  METROPOLITAN DISTRICT                |NOTIFICATION TIME: 18:23[EST]|
|    CITY:  HARTFORD                 REGION:  1  |EVENT DATE:        01/26/2000|
|  COUNTY:                            STATE:  CT |EVENT TIME:             [EST]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  01/26/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN ROGGE           R1      |
|                                                |                             |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  EARL DELANO                  |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NCFR                     NON CFR REPORT REQMNT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REQUIRED REPORT - EXPLOSION IN SHREDDER, NO DAMAGE TO SOURCE IN LEVEL        |
| DETECTOR                                                                     |
|                                                                              |
| The operating procedures require notification of the NRC of any explosion in |
| the trash shredders, even if no damage occurs to the source in the level     |
| measuring device.  It has been determined that small gas welding bottle that |
| contained acetylene caused an explosion in the shredder at Metropolitan      |
| District.  The source was not damaged.  Local authorities were informed and  |
| the fire department made the determination of the probable cause.            |
+------------------------------------------------------------------------------+
