The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for January 5, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
01/04/2000 - 01/05/2000
** EVENT NUMBERS **
36513 36559 36560 36561
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 36513 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WISCONSIN ELECTRIC POWER COMPANY |NOTIFICATION DATE: 12/15/1999|
|LICENSEE: K-RAY |NOTIFICATION TIME: 17:54[EST]|
| CITY: KENOSHA REGION: 3 |EVENT DATE: 12/15/1999|
| COUNTY: STATE: WI |EVENT TIME: [CST]|
|LICENSE#: 48-16729-01 AGREEMENT: N |LAST UPDATE DATE: 01/04/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GARY SHEAR R3 |
| |KEVIN RAMSEY (FAX) |
+------------------------------------------------+ |
| NRC NOTIFIED BY: KJELL JOHANSEN | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|CDEG 21.21(c)(3)(i) DEFECTS/NONCOMPLIANCE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| K-RAY 706P SOURCE HOLDER DEVELOPED CRACK |
| |
| The licensee discovered a crack, about 2-3 inches in length, in the K-Ray |
| 706P source holder, possibly in a weld. The gauge, containing a 10-mCi |
| Cs-137 source, is in a radioactive labeled room under a coal pipe at the |
| Pleasant Prairie Plant, and it has been wrapped with plastic and labeled |
| with radioactive stickers. K-Ray has been notified and will replace the |
| gauge before the end of the year. A 30-day written report will follow. |
| |
| (Call the NRC operations officer for a contact telephone number.) |
| |
| *** RETRACTION ON 01/03/00 AT 1707ET FROM KJELL JOHANSEN TAKEN BY MACKINNON |
| *** |
| |
| The licensee is retracting this report because the crack in the K-RAY 706P |
| does not meet the definition of Substantial Safety Hazard found in 10 CFR |
| 21.3. Per 10 CFR 21.3 Substantial Safety Hazard "means a loss of safety |
| function to the extent that there is a major reduction in the degree of |
| protection provided to public health and safety for any facility or activity |
| licensed, other than for export, etc." The contact radiation level on the |
| cracked K-RAY 706P was the same level as the K-RAY 706P without a crack, |
| 1.5mrem/hr. A 30 day report will be filed. R3DO (MADERA) notified. |
| Facsimile sent to Kevin Ramsey (NMSS) |
| |
| *** UPDATE ON 1/4/00 @ 1100 BY JOHANSEN TO GOULD *** |
| |
| Equipment model number was incorrect. The correct model number is 7062P |
| instead of 706P. |
| |
| Notified Reg 3 RDO(Madera) and NMSS(Ramsey) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 36559 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 01/04/2000|
|LICENSEE: TERRA-MAR, INC. |NOTIFICATION TIME: 09:10[EST]|
| CITY: FORT WORTH REGION: 4 |EVENT DATE: 12/30/1999|
| COUNTY: STATE: TX |EVENT TIME: 04:00[CST]|
|LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 01/04/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CHARLES CAIN R4 |
| |DON COOL |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES OGDEN | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN TROXLER GAUGE |
| |
| The following text is a portion of a facsimile received from the Texas |
| Department of Health: |
| |
| "Troxler Model 3411-B, Serial # 10518, stolen December 30, 1999, between 4 |
| and 4:30 p.m. along with a company pickup truck (1995, White Isuzu Pup with |
| markings Terra-Mar, Inc. on both doors, License Plate # SL9314). Reported by |
| Texas Licensee: Terra-Mar, Inc., 2402 Gravel Drive, Fort Worth, Texas |
| 76118-6935. Gauge includes two radioactive sources: 1) Am-241:Be, 40 |
| millicuries, Serial # 46-1940; and 2) C-137, 8.4 millicuries, Serial # |
| 40-7844. Completed work Thursday and departed worksite at Carlswell Naval |
| Reserve Base, Texas Army National Guard, Fuel Hanger site and departed. |
| Truck and operator have not been seen since. Suspected by firm that the |
| primary theft was for the vehicle for the holiday weekend. A new operator |
| /technician is the primary suspect in the theft of both the gauge and |
| vehicle. Neither truck nor gauge have been located. The theft has been |
| reported to Fort Worth Police Department (Report # 00006249) and the Texas |
| Department of Public Safety. A copy of the report is not yet available." |
| |
| (Call the NRC Operations Center for a contact telephone number and |
| address.) |
| |
| *** UPDATE ON 01/04/00 AT 1705 ET FROM JAMES OGDEN TAKEN BY MACKINNON *** |
| |
| The Troxler Model 3411-B, Serial # 10518, stolen December 30, 1999, from |
| Fort Worth, Texas , has been recovered today (January 4, 2000) and appears |
| to be intact. The gauge is currently being leak tested by the licensee. |
| |
| NRC R4DO (Chuck Cain) and NMSS EO ( John Hickey) notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 36560 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WASHINGTON DEPARTMENT OF HEALTH |NOTIFICATION DATE: 01/04/2000|
|LICENSEE: INSPECTION SERVICE INC. |NOTIFICATION TIME: 10:40[EST]|
| CITY: PASCO REGION: 4 |EVENT DATE: 12/19/1999|
| COUNTY: STATE: WA |EVENT TIME: [PST]|
|LICENSE#: WN-IR064-1 AGREEMENT: Y |LAST UPDATE DATE: 01/04/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CHARLES CAIN R4 |
| |BRIAN SMITH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: TERRY FRAZEE | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
|IBBF 30.50(b)(2)(ii) EQUIP DISABLED/FAILS | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - INDUSTRIAL RADIOGRAPHY CAMERA AUTO-LOCKING |
| MECHANISM FAILED |
| |
| THIS EVENT WAS E-MAILED TO THE HEADQUARTERS OPERATION CENTER |
| |
| "This is notification of an event in Washington state as reported to the WA |
| Department of Health, Division of Radiation Protection. |
| |
| STATUS: new |
| |
| Licensee: Inspection Service Inc. |
| City and state: Kennewick, WA |
| License number: WN-IR064-1 |
| Type of license: Industrial Radiography |
| |
| Date of event: December 19, 1999 |
| Location of Event: Pasco, WA |
| ABSTRACT: The auto-locking mechanism malfunctioned on an INC model IR 100 |
| industrial radiography camera containing approximately 25 Curies of Ir-192. |
| The malfunction was detected during the radiographer's survey of the |
| circumference of the camera following the completion of a shot when |
| approximately 500 mRem per hour was noted at the exit port of the camera. |
| |
| Upon cranking in the source, the radiographer had observed the "plunger" |
| drop into position indicating the source had been fully retracted and the |
| auto-locking mechanism engaged. Upon reaching the camera the radiographer |
| key-locked the camera while initiating the required circumference survey. |
| Once locked, the key could not be moved to unlock the camera. The |
| radiographer discovered that the source was not fully shielded and was not |
| locked in place. The camera could not be unlocked to crank the source the |
| extra one eighth turn needed to fully shield the source although it could be |
| cranked out. The manufacturer was contacted and a procedure obtained for |
| by-passing the locking mechanism. The licensee was told by the manufacturer |
| that this type of event is 'extremely rare but it does happen'. |
| |
| Using the procedure supplied by the manufacturer, the licensee was able to |
| remove the locking assembly, free the key lock, re-set the auto-lock, |
| re-assemble the mechanism and retract the source into its fully shielded |
| position. No unusual exposures were received by any personnel involved |
| during this event or the successful completion of this operation. |
| |
| What is the notification or reporting criteria involved? Equipment |
| malfunction: inability to retract source to fully shielded position and |
| secure it in this position. |
| |
| Activity and isotope(s) involved: 25 curies of Ir-192 |
| Overexposures? NONE |
| |
| Device (HDR, etc.) Mfg., Model; computer code: I.N.C. model IR 100, serial |
| number 4495" |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36561 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK REGION: 2 |NOTIFICATION DATE: 01/04/2000|
| UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 14:34[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 01/04/2000|
+------------------------------------------------+EVENT TIME: 12:50[EST]|
| NRC NOTIFIED BY: DAVE JESTER |LAST UPDATE DATE: 01/04/2000|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |THOMAS DECKER R2 |
|10 CFR SECTION: | |
|AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| EMERGENCY OFFSITE SIRENS INOPERABLE |
| |
| On 01/03/00 at 0557 ET twelve emergency notification sirens were inoperable |
| due to a loss of power to the sirens. Power was restored to all of the |
| sirens by 0714 ET on 01/03/00. This item was not identified until 01/04/00 |
| at 1250 ET when the licensee performed a printout of their emergency |
| offsite sirens status at the EOF. The power loss was due to an insulator |
| breakdown on a transformer on the CP&L system. |
| |
| Other means of warning the public were available. |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021