Event Notification Report for December 23, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/22/1999 - 12/23/1999 ** EVENT NUMBERS ** 36473 36533 36534 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 36473 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: POINT BEACH REGION: 3 |NOTIFICATION DATE: 11/29/1999| | UNIT: [1] [2] [] STATE: WI |NOTIFICATION TIME: 16:43[EST]| | RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 11/29/1999| +------------------------------------------------+EVENT TIME: [CST]| | NRC NOTIFIED BY: GOSPAREK |LAST UPDATE DATE: 12/22/1999| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |GEOFFREY WRIGHT R3 | |10 CFR SECTION: | | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Refueling |0 Refueling | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SECURITY EVENT | | | | Unescorted access granted inappropriately. Contact the NRC Operations Center | | for additional details. The NRC resident inspector has been informed by the | | licensee. | | | | ********** UPDATE AT 1122 EST ON 12/22/99 FROM BRIAN KOPETSKY TO LEIGH | | TROCINE ********** | | | | The licensee is retracting this event notification. After further review of | | this event, Regulatory Guide 562, and Generic Letter 91-03, the licensee | | determined that this event was loggable and not reportable because there was | | no safety significance to the event and because the licensee compensated for | | the event. | | | | The licensee notified the NRC Region 3 office (Terry Madeda) and plans to | | notify the NRC resident inspector. The NRC operations officer notified the | | R3DO (Ring). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 36533 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 12/22/1999| | UNIT: [] [2] [] STATE: IL |NOTIFICATION TIME: 17:10[EST]| | RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 12/22/1999| +------------------------------------------------+EVENT TIME: 13:56[CST]| | NRC NOTIFIED BY: SCOTT BRILEY |LAST UPDATE DATE: 12/22/1999| | HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |MARK RING R3 | |10 CFR SECTION: | | |AINB 50.72(b)(2)(iii)(B) POT RHR INOP | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SHUTDOWN COOLING INOPERABLE WHILE IN MODE ONE | | | | The logic for the Shutdown Cooling System would have prevented placing | | Shutdown Cooling in service. Although Shutdown Cooling is not currently | | required in mode 1, the logic is required. A component had high resistance | | which generated a signal like an actual high temperature condition. This | | condition would have prevented placing Shutdown Cooling in service. The | | high resistance is believed to have been caused by dirty contacts. | | | | The problem has been corrected, and the components are being retested. | | | | The licensee notified the NRC resident inspector. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 36534 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 12/22/1999| |LICENSEE: REED ENGINEERING GROUP, INC. |NOTIFICATION TIME: 15:00[EST]| | CITY: DALLAS REGION: 4 |EVENT DATE: 12/15/1999| | COUNTY: STATE: TX |EVENT TIME: 23:00[CST]| |LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 12/22/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM JOHNSON R4 | | |SUSAN SHANKMAN NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: JAMES OGDEN | | | HQ OPS OFFICER: DOUG WEAVER | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE | | | | A Troxler nuclear gauge (Model 3430, Serial No. 26619) with the following | | sources: Cs-137, S/N: 75-8687, nominal activity 8 millicuries, and | | Am-241:Be, S/N: 47-23085, nominal activity 40 millicuries, was stolen from | | the Dallas, Texas, area during the hours of darkness December 15-16, 1999. | | A police report has been filed. The gauge was stolen from the back of a | | Licensee's pickup truck by cutting the security chain. The gauge has not | | been recovered. | | | | A verbal report has also been filed with the NRC Regional Office. Delay in | | notification has been due to delays within this headquarters. Surrounding | | states and Mexico have also been notified of this theft. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021