Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for December 23, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           12/22/1999 - 12/23/1999

                              ** EVENT NUMBERS **

36473  36533  36534  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36473       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 11/29/1999|
|    UNIT:  [1] [2] []                STATE:  WI |NOTIFICATION TIME: 16:43[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        11/29/1999|
+------------------------------------------------+EVENT TIME:             [CST]|
| NRC NOTIFIED BY:  GOSPAREK                     |LAST UPDATE DATE:  12/22/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEOFFREY WRIGHT      R3      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY EVENT                                                               |
|                                                                              |
| Unescorted access granted inappropriately. Contact the NRC Operations Center |
| for additional details. The NRC resident inspector has been informed by the  |
| licensee.                                                                    |
|                                                                              |
| ********** UPDATE AT 1122 EST ON 12/22/99 FROM BRIAN KOPETSKY TO LEIGH       |
| TROCINE **********                                                           |
|                                                                              |
| The licensee is retracting this event notification.  After further review of |
| this event, Regulatory Guide 562, and Generic Letter 91-03, the licensee     |
| determined that this event was loggable and not reportable because there was |
| no safety significance to the event and because the licensee compensated for |
| the event.                                                                   |
|                                                                              |
| The licensee notified the NRC Region 3 office (Terry Madeda) and plans to    |
| notify the NRC resident inspector.  The NRC operations officer notified the  |
| R3DO (Ring).                                                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36533       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 12/22/1999|
|    UNIT:  [] [2] []                 STATE:  IL |NOTIFICATION TIME: 17:10[EST]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        12/22/1999|
+------------------------------------------------+EVENT TIME:        13:56[CST]|
| NRC NOTIFIED BY:  SCOTT BRILEY                 |LAST UPDATE DATE:  12/22/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MARK RING            R3      |
|10 CFR SECTION:                                 |                             |
|AINB 50.72(b)(2)(iii)(B) POT RHR INOP           |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SHUTDOWN COOLING INOPERABLE WHILE IN MODE ONE                                |
|                                                                              |
| The logic for the Shutdown Cooling System would have prevented placing       |
| Shutdown Cooling in service.  Although Shutdown Cooling is not currently     |
| required in mode 1, the logic is required.  A component had high resistance  |
| which generated a signal like an actual high temperature condition.  This    |
| condition would have prevented placing Shutdown Cooling in service.   The    |
| high resistance is believed to have been caused by dirty contacts.           |
|                                                                              |
| The problem has been corrected, and the components are being retested.       |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36534       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 12/22/1999|
|LICENSEE:  REED ENGINEERING GROUP, INC.         |NOTIFICATION TIME: 15:00[EST]|
|    CITY:  DALLAS                   REGION:  4  |EVENT DATE:        12/15/1999|
|  COUNTY:                            STATE:  TX |EVENT TIME:        23:00[CST]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  12/22/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |WILLIAM JOHNSON      R4      |
|                                                |SUSAN SHANKMAN       NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES OGDEN                  |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE                       |
|                                                                              |
| A Troxler nuclear gauge (Model 3430, Serial No. 26619) with the following    |
| sources: Cs-137, S/N: 75-8687, nominal activity 8 millicuries, and           |
| Am-241:Be, S/N: 47-23085, nominal activity 40 millicuries, was stolen from   |
| the Dallas, Texas, area during the hours of darkness December 15-16, 1999.   |
| A police report has been filed.  The gauge was stolen from the back of a     |
| Licensee's pickup truck by cutting the security chain. The gauge has not     |
| been recovered.                                                              |
|                                                                              |
| A verbal report has also been filed with the NRC Regional Office. Delay in   |
| notification has been due to delays within this headquarters. Surrounding    |
| states and Mexico have also been notified of this theft.                     |
+------------------------------------------------------------------------------+