Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for December 8, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           12/07/1999 - 12/08/1999

                              ** EVENT NUMBERS **

36410  36492  36493  36494  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36410       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 11/07/1999|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 15:19[EST]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        11/07/1999|
+------------------------------------------------+EVENT TIME:        13:48[CST]|
| NRC NOTIFIED BY:  JIM McKAY                    |LAST UPDATE DATE:  12/07/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JAMES CREED          R3      |
|10 CFR SECTION:                                 |                             |
|AINA 50.72(b)(2)(iii)(A) POT UNABLE TO SAFE SD  |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HIGH PRESSURE COOLANT INJECTION (HPCI) SYSTEM DECLARED INOPERABLE DUE TO     |
| FAILURE OF THE ASSOCIATED ROOM COOLER                                        |
|                                                                              |
| "DURING NORMAL OPERATIONS, HPCI HAS BEEN DECLARED INOPERABLE IN ACCORDANCE   |
| WITH TECH SPEC SECTION 3.5.A.3.g.  HPCI IS INOPERABLE DUE TO THE FAILURE OF  |
| SUPPORT AUXILIARY EQUIPMENT, i.e., THE VENTILATION COOLING COIL HAS A MAJOR  |
| LEAK REQUIRING ISOLATION OF THE VENTILATION UNIT.  HPCI IS IN A 14-DAY       |
| LCO."                                                                        |
|                                                                              |
| THE LICENSEE PLANS TO INFORM  STATE/LOCAL AGENCIES AS A COURTESY AND THE NRC |
| RESIDENT INSPECTOR.                                                          |
|                                                                              |
| * * * RETRACTED AT 1050 EST ON 12/7/99 FROM McKAY TO STEVE SANDIN * * *      |
|                                                                              |
| "This notification retracts a notification made 11/7/99 due to HPCI being    |
| declared inoperable for failure of required auxiliary support equipment.     |
| V-AC-8B is one of two room coolers in the HPCI room.  V-AC-8B, considered    |
| required auxiliary support equipment, was isolated due to a coil leak.       |
|                                                                              |
| "Further analysis shows that [the] HPCI building room would remain under     |
| it's design temperature and operable with no room coolers operable.          |
| Investigation following the event determined that the leaking water did not  |
| have any effect on HPCI instruments or operability.  The leak was repaired,  |
| and the system [was] returned to normal standby condition."                  |
|                                                                              |
| The licensee intends to notify the NRC Resident Inspector.  The Headquarters |
| Operations Officer notified the R3DO (Patrick Hiland).                       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36492       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK                REGION:  2  |NOTIFICATION DATE: 12/07/1999|
|    UNIT:  [1] [2] []                STATE:  NC |NOTIFICATION TIME: 11:15[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        12/06/1999|
+------------------------------------------------+EVENT TIME:        15:15[EST]|
| NRC NOTIFIED BY:  REINSBURROW                  |LAST UPDATE DATE:  12/07/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |AL BELISLE           R2      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FITNESS-FOR-DUTY REPORT                                                      |
|                                                                              |
| A contract supervisor has tested positive for illegal drug use during a      |
| random fitness-for-duty test.  The employee's access into the plant          |
| protected area has been suspended.  Refer to the HOO Log for additional      |
| details.                                                                     |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36493       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TURKEY POINT             REGION:  2  |NOTIFICATION DATE: 12/07/1999|
|    UNIT:  [3] [] []                 STATE:  FL |NOTIFICATION TIME: 14:24[EST]|
|   RXTYPE: [3] W-3-LP,[4] W-3-LP                |EVENT DATE:        12/07/1999|
+------------------------------------------------+EVENT TIME:        13:20[EST]|
| NRC NOTIFIED BY:  ROSS FREW                    |LAST UPDATE DATE:  12/07/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |EDWARD MCALPINE      R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION REGARDING THE DISCOVERY OF A DEAD FLORIDA CROCODILE (AN |
| ENDANGERED SPECIES) IN THE SITE'S COOLING CANAL SYSTEM                       |
|                                                                              |
| At 1320 on 12/07/99, the Land Utilization Group notified the control room of |
| the discovery of a dead crocodile in the site's cooling canal system.  It is |
| currently believed that the dead crocodile lost a fight with a larger        |
| crocodile.                                                                   |
|                                                                              |
| The licensee notified the NRC resident inspector.  In accordance with an     |
| Environmental Permit, the licensee also plans to notify the Florida Game and |
| Freshwater Fish Commission.                                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36494       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 12/07/1999|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 20:21[EST]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        12/07/1999|
+------------------------------------------------+EVENT TIME:        17:55[CST]|
| NRC NOTIFIED BY:  JIM McKAY                    |LAST UPDATE DATE:  12/07/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |PATRICK HILAND       R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       92       Power Operation  |92       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| INOPERABILITY OF HPCI DUE TO A LOOSE PIPE SUPPORT                            |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "During normal plant operation the High Pressure Core Injection (HPCI)       |
| system was declared inoperable [in accordance with] Technical Specification  |
| section 3.5.A.3.g.  HPCI is inoperable due to an inoperable pipe support on  |
| the steam supply to the HPCI drive turbine.  The support was observed to be  |
| loose, and the anchor bolts on the base of the support are pulled out of the |
| wall approximately 3/8".  HPCI is in a 14-day [limiting condition for        |
| operation]."                                                                 |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021