Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for November 29, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           11/26/1999 - 11/29/1999

                              ** EVENT NUMBERS **

36464  36465  36466  36467  36468  36469  36470  36471  

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   36464       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 11/26/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 06:46[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        11/26/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        03:00[EST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  11/26/1999|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |RONALD GARDNER       R3      |
|  DOCKET:  0707002                              |BRIAN SMITH          NMSS    |
+------------------------------------------------+FRANK CONGEL         IRO     |
| NRC NOTIFIED BY:  RON CRABTREE                 |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| NRC BULLETIN 91-01 RESPONSE (4-HOUR REPORT) - LOSS OF SPACING AND MODERATION |
| CONTROLS                                                                     |
|                                                                              |
| The following text is a portion of a facsimile received from Portsmouth:     |
|                                                                              |
| "On 11/26/99 at 0341 hours, the Plant Shift Superintendent (PSS) was         |
| notified that NCSA-PLANT062.A02 Nuclear Criticality Safety Approval (NCSA)   |
| requirements were not being met.  A conical section of pipe removed during   |
| maintenance activities on cell 33-5-10 was staged less than 2 feet from      |
| other uranium-bearing piping in the cell housing.  It was also identified    |
| that the flanged openings of the conical transition piece were not covered   |
| as required by NCSA-PLANT062.A02.  [These issues were discovered at 0300     |
| hours.]"                                                                     |
|                                                                              |
| "This violated requirement #3 of NCSA-PLANT062.A02, which states in part:    |
| 'Both favorable and unfavorable types of uncomplicated handling (UH)         |
| equipment shall be spaced a minimum of 2 feet edge-to-edge from other        |
| uranium-bearing equipment.'  Requirement #4, which states that               |
| openings/penetrations made during maintenance activities shall be covered to |
| minimize the potential for moderator collection and moist air exposure when  |
| unattended, was also violated."                                              |
|                                                                              |
| "This is reportable under NRC Bulletin 91-01, 4-hour criticality control."   |
|                                                                              |
| "There was no loss of hazardous/radioactive material or                      |
| radioactive/radiological contamination exposure as a result of this event."  |
|                                                                              |
| Portsmouth personnel notified the NRC resident inspector and plan to notify  |
| the Department of Energy site representative.                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36465       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 11/26/1999|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 09:12[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        11/26/1999|
+------------------------------------------------+EVENT TIME:        08:00[EST]|
| NRC NOTIFIED BY:  DAVE WILLIAMS                |LAST UPDATE DATE:  11/26/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LEN WERT             R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION REGARDING A LIVE SEA TURTLE REMOVED FROM THE INTAKE     |
| CANAL BARRIER NET                                                            |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "At approximately 0730 on 11/26/99, a live juvenile loggerhead sea turtle    |
| was removed from the barrier net in the common plant intake canal.  The      |
| Florida Department of Environmental Protection was notified at approximately |
| 0800 for transfer to a rehabilitation facility."                             |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36466       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALLAWAY                 REGION:  4  |NOTIFICATION DATE: 11/26/1999|
|    UNIT:  [1] [] []                 STATE:  MO |NOTIFICATION TIME: 17:16[EST]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        11/26/1999|
+------------------------------------------------+EVENT TIME:        12:27[CST]|
| NRC NOTIFIED BY:  GARY OLMSTEAD                |LAST UPDATE DATE:  11/26/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BLAIR SPITZBERG      R4      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| Unit experienced an automatic reactor trip following a momentary loss of     |
| power to an I&C power supply that resulted in a low Steam Generator water    |
| level.                                                                       |
|                                                                              |
| "This event is being reported in accordance with 10CFR50.72(b)(2)(ii) due to |
| an automatic Reactor Trip and subsequent Aux Feedwater actuation and         |
| Feedwater isolation:                                                         |
|                                                                              |
| "On 11/26/99 at 1227 CST with Callaway plant at 100% reactor power, a        |
| Reactor Trip occurred on low Steam Generator 'A' level due to an apparent    |
| momentary loss of power in Control Cabinet [Relay Panel] RP043.  At 1204,    |
| annunciator 93A 'Power Control System (PCS) Power Failure' alarmed due to a  |
| failed RP043 primary power supply. Initial investigation revealed a failed   |
| fuse in the RP043 primary power supply. The secondary power supply           |
| immediately picked up load without incident.                                 |
|                                                                              |
| "Subsequent to the primary power supply failure, I&C technicians were sent   |
| to the RP043 cabinet and the Primary Equipment Operator was sent to RP043    |
| supply breaker PG19GCR218 to investigate.  During this investigation, Main   |
| Feedwater Regulating valve [MFRV] 'A' went shut and both Main Feedwater      |
| Pumps [MFPs] went to their low speed stops.  Attempts by the Reactor         |
| Operator to take manual control of 'A'  MFRV and the MFPs were unsuccessful  |
| resulting in the aforementioned Reactor Trip.                                |
|                                                                              |
| "Discussions with I&C personnel stationed at RP043 indicated the secondary   |
| power supplies appeared energized throughout the event.  Discussions with    |
| the Primary EO indicated he checked PG19GCR218 in the closed position        |
| coincident with the trip.  Plant personnel are currently investigating       |
| PG19GCR218 and the apparent momentary loss of power to RP043.  The plant is  |
| currently stable in Mode 3 with RCS pressure at 2237 psig and RCS            |
| temperature at 557.8 F.                                                      |
|                                                                              |
| "Additional information: The NRC Senior Resident Inspector was contacted at  |
| 1310 and responded to the Control Room."                                     |
|                                                                              |
| Auxiliary Feedwater is currently supplying the Steam Generators with steam   |
| flow to the Main Condenser for decay heat removal.  All control rods fully   |
| inserted.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36467       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 11/26/1999|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 17:34[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        11/26/1999|
+------------------------------------------------+EVENT TIME:        17:12[EST]|
| NRC NOTIFIED BY:  DAVE WILLIAMS                |LAST UPDATE DATE:  11/26/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LEN WERT             R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO STATE AGENCY  REGARDING DEAD SEA TURTLE FOUND IN     |
| BARRIER NET OF THE INTAKE CANAL                                              |
|                                                                              |
| "[A] NOTIFICATION [WAS] MADE TO [THE] FLORIDA DEPARTMENT OF ENVIRONMENTAL    |
| PROTECTION (DEP) REGARDING [THE] REMOVAL OF [A] DEAD SUB-ADULT LOGGERHEAD    |
| SEA TURTLE FROM THE BARRIER NET IN THE COMMON PLANT INTAKE CANAL.  THE       |
| TURTLE WAS REMOVED AT APPROXIMATELY 1700 [HOURS] ON 11/26/99, AND THE        |
| FLORIDA DEP WAS NOTIFIED AT 1710 HOURS.  [THE] ANIMAL WAS FOUND WITH         |
| MONOFILAMENT FISHING LINE AROUND [THE] FRONT FLIPPERS AND [THE] MORTALITY IS |
| NOT BELIEVED TO BE CAUSALLY RELATED TO PLANT OPERATIONS.  THE LICENSEE WILL  |
| NOTIFY THE NRC RESIDENT INSPECTOR."                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   36468       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FAIRVIEW SOUTHDALE HOSPITAL          |NOTIFICATION DATE: 11/26/1999|
|LICENSEE:  FAIRVIEW SOUTHDALE HOSPITAL          |NOTIFICATION TIME: 23:46[EST]|
|    CITY:  EDINA                    REGION:  3  |EVENT DATE:        11/25/1999|
|  COUNTY:                            STATE:  MN |EVENT TIME:        07:05[CST]|
|LICENSE#:  22-00015-02           AGREEMENT:  N  |LAST UPDATE DATE:  11/26/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |RONALD GARDNER       R3      |
|                                                |JOE HOLONICH         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  DR. L. LEWANOWSKI            |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|LADM 35.33(a)            MED MISADMINISTRATION  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FEMALE PATIENT RECEIVED LESS THAN THE PRESCRIBED DOSE DUE TO TECHNICIAN      |
| ERROR                                                                        |
|                                                                              |
| A FEMALE PATIENT UNDERGOING TREATMENT FOR ENDOMETRIAL CANCER RECEIVED 5072   |
| RATHER THAN THE 6500 CENTIGRAY PRESCRIBED DUE TO TECHNICIAN ERROR IN LOADING |
| TWO (2) OLD CESIUM-137 SOURCES INTO THE APPLICATOR.  THE NEWER SOURCES (25   |
| MILLIGRAMS RADIUM EQUIVALENT EACH) WERE CLEARLY LABELED AND INDICATED ON THE |
| HOSPITAL FORMS.  THE PRESCRIBING PHYSICIAN WAS INFORMED AND REQUESTED THAT   |
| THE PATIENT NOT BE NOTIFIED PENDING AN EVALUATION OF  WHETHER ADDITIONAL     |
| TREATMENT IS REQUIRED.  THE LICENSEE WILL SUBMIT A WRITTEN REPORT WITHIN     |
| FIFTEEN DAYS.                                                                |
|                                                                              |
| CALLTHE HEADQUARTERS OPERATIONS OFFICER FOR CONTACT INFORMATION.             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36469       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WATERFORD                REGION:  4  |NOTIFICATION DATE: 11/27/1999|
|    UNIT:  [3] [] []                 STATE:  LA |NOTIFICATION TIME: 07:00[EST]|
|   RXTYPE: [3] CE                               |EVENT DATE:        11/27/1999|
+------------------------------------------------+EVENT TIME:        05:33[CST]|
| NRC NOTIFIED BY:  P. BOCSKOV/B. LIETZKE        |LAST UPDATE DATE:  11/27/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          ALE                   |BLAIR SPITZBERG      R4      |
|10 CFR SECTION:                                 |ELINOR ADENSAM       NRR     |
|AAEC 50.72 (a) (1) (I)   EMERGENCY DECLARED     |FRANK CONGEL         IRO     |
|                                                |THOMAS MCKENNA       RCT     |
|                                                |SUE GAGNER           OPA     |
|                                                |KEN CIBOCH           FEMA    |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          N       0        Hot Shutdown     |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - ALERT DUE TO SUDDEN DEPRESSURIZATION OF RCS AND LOSS OF 3000 GALLONS FROM  |
| RCS -                                                                        |
|                                                                              |
| ON 11/26/99, WATERFORD WAS SHUT DOWN FROM 100% POWER TO REPAIR A LEAK ON A   |
| MAIN STEAM LINE DRAIN LINE.                                                  |
|                                                                              |
| AT 0500 CST ON 11/27/99, WITH THE PLANT IN MODE 4 (HOT SHUTDOWN), THE        |
| LICENSEE OPENED THE SUCTION VALVE (#SI-407B) TO THE TRAIN 'B' LOW PRESSURE   |
| SAFETY INJECTION PUMP TO PLACE THE PLANT ON SHUTDOWN COOLING.  CONTROL ROOM  |
| OPERATORS HEARD A LOUD NOISE.  APPROXIMATELY 3000 GALLONS DRAINED FROM THE   |
| REACTOR COOLANT SYSTEM (RCS) INTO THE REFUELING WATER STORAGE POOL IN ABOUT  |
| 2 MINUTES.  THE WATER LEVEL IN THE PRESSURIZER DROPPED FROM 35% TO 0%.  THE  |
| PRESSURIZER HEATERS TRIPPED.  RCS PRESSURE DROPPED FROM 350 PSIG TO 100      |
| PSIG.  RCS TEMPERATURE REMAINED AT 295�F.  THE LICENSEE CLOSED THE VALVE     |
| WHICH STOPPED THE DRAIN FROM THE RCS AND REFILLED THE PRESSURIZER TO 53%     |
| USING THE HIGH PRESSURE SAFETY INJECTION PUMP.                               |
|                                                                              |
| AT 0533 CST ON 11/27/99, THE LICENSEE DECLARED AN ALERT DUE TO A             |
| PRECAUTIONARY STATEMENT IN THE EMERGENCY OPERATING PROCEDURE DUE TO THE      |
| SUDDEN DEPRESSURIZATION OF THE RCS.  THE LICENSEE NOTIFIED STATE AND LOCAL   |
| OFFICIALS AND THE NRC SENIOR RESIDENT INSPECTOR.  THE LICENSEE CALLED        |
| PERSONNEL TO COME TO THE PLANT TO STAFF THEIR EMERGENCY OPERATIONS FACILITY  |
| AND TECHNICAL SUPPORT CENTER AND ACTIVATED THEIR EMERGENCY RESPONSE DATA     |
| SYSTEM.                                                                      |
|                                                                              |
| THE PLANT IS IN NATURAL CIRCULATION TO STEAM GENERATOR (S/G) #2 TO THE MAIN  |
| CONDENSER.  S/G #1 IS INOPERABLE.  THERE WAS NO RELEASE OF RADIATION AND NO  |
| PERSONNEL WERE INJURED.                                                      |
|                                                                              |
| AT 0640 CST ON 11/27/99, THE NRC ENTERED THE MONITORING PHASE OF NORMAL      |
| RESPONSE MODE.  NRC REGION 4 STAFFED THEIR INCIDENT RESPONSE CENTER.  THE    |
| LICENSEE IS PREPARING A PRESS RELEASE.                                       |
|                                                                              |
| THE PLANT IS STABLE IN MODE 4 (HOT SHUTDOWN).                                |
|                                                                              |
| SUBSEQUENTLY, THE LICENSEE DISCOVERED THAT A 6 INCH MANUAL RECIRC VALVE      |
| (#SI-417B) WAS OPEN, BUT WAS INDICATING CLOSED.  THE REACH ROD TO THE VALVE  |
| WAS BROKEN.  THE LICENSEE DETERMINED THAT THE VALVE HAD BEEN OPEN FOR ABOUT  |
| A WEEK.                                                                      |
|                                                                              |
| AT 1100 EST ON 11/27/99, A COMMISSIONERS' ASSISTANTS BRIEFING WAS HELD WITH  |
| THE FOLLOWING ATTENDEES:  IRO FRANK CONGEL, JOE GIITTER; NRR PROJECT         |
| DIRECTOR STU RICHARDS; OPA BETH HAYDEN; OSP PAUL LOHAUS; OIP RON HAUBER; OCA |
| LAURA GERKE; EDO DAVE LANGE; DEDMRS PAPERIELLO; SECY ANNETTE VIETTI-COOK;    |
| CHAIRMAN MESERVE (GLEN TRACY); COMM DICUS (TOM HILTZ); COMM McGAFFIGAN       |
| (JANET SCHLUETER); COMM DIAZ (TONY HSIA); COMM MERRIFIELD (BRIAN McCABE);    |
| REGION 4 TOM ANDREWS, CHRIS KENNEDY, ELLIS MERSCHOFF, KEN BROCKMAN           |
| (BRIEFER); SRI TOM FARNHOLTZ.                                                |
|                                                                              |
| * * * UPDATE AT 1335 EST ON 11/27/99 FROM MIKE MASON TO S. SANDIN * * *      |
|                                                                              |
| THE LICENSEE EXITED THE ALERT AT 1226 CST AFTER VERIFYING THAT THE PLANT WAS |
| IN MODE 5 AND STABLE (TERMINATION CRITERIA).  THE LICENSEE INFORMED          |
| STATE/LOCAL AGENCIES AND THE NRC RESIDENT INSPECTOR.  THE NRC OPERATIONS     |
| OFFICER NOTIFIED R4(MERSCHOFF), EO(ADENSAM), IRO(CONGEL), PAO(GAGNER,        |
| JASINSKI), EDO(PAPERIELLO), CHAIRMAN MESERVE(TRACY), FEMA(SULLIVAN),         |
| DOE(YOUNG), EPA(DiGIORGIO), USDA(CONLEY) AND HHS(BERGER).                    |
|                                                                              |
| AT 1345 EST THE NRC EXITED THE MONITORING PHASE OF NORMAL RESPONSE MODE PER  |
| A 1315 EST CONFERENCE CALL INVOLVING R4(MERSCHOFF), NRR(COLLINS, RICHARDS),  |
| IRO(CONGEL) AND EDO(TRAVERS).                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36470       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD             REGION:  3  |NOTIFICATION DATE: 11/28/1999|
|    UNIT:  [1] [] []                 STATE:  IA |NOTIFICATION TIME: 02:13[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        11/27/1999|
+------------------------------------------------+EVENT TIME:        22:35[CST]|
| NRC NOTIFIED BY:  DAVE SCHUSSLER               |LAST UPDATE DATE:  11/28/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RONALD GARDNER       R3      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       1        Startup          |1        Startup          |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - SAFETY/RELIEF VALVE OPENED FOR 1 MINUTE DURING MAINTENANCE ACTIVITIES -    |
|                                                                              |
| DURING A REACTOR STARTUP WITH REACTOR AT 1% POWER, MAINTENANCE TECHNICIANS   |
| WERE PREPARING TO PERFORM AN INSPECTION ON THE 125 VDC DIVISION I ELECTRICAL |
| DISTRIBUTION SYSTEM BY USING A SCOUT GROUND DETECTION DEVICE TO TROUBLESHOOT |
| A SYSTEM GROUND.  DURING THE MAINTENANCE INSPECTION, THE SCOUTING DEVICE     |
| CAUSED SAFETY/RELIEF VALVE (SRV) (#PSV-4402) (ADS VALVE) TO OPEN AS          |
| INDICATED BY "TAILPIPE HI TEMP" ALARM.  THE OPENING OF THE SRV CAUSED THE    |
| REACTOR VESSEL WATER LEVEL TO SWELL FROM A NORMAL LEVEL OF 190 INCHES TO 200 |
| INCHES.  OTHER ALARMS ASSOCIATED WITH THE TROUBLESHOOTING WERE ALSO RECEIVED |
| IN THE CONTROL ROOM.  MAINTENANCE ACTIVITIES ON 125 VDC DIVISION I           |
| ELECTRICAL DISTRIBUTION SYSTEM WERE QUICKLY HALTED AND THE SRV COMPLETELY    |
| CLOSED ABOUT ONE MINUTE AFTER OPENING CAUSING THE REACTOR VESSEL WATER LEVEL |
| TO DROP TO 178 INCHES. THE CONDENSATE SYSTEM WAS USED TO RESTORE WATER LEVEL |
| TO ITS NORMAL LEVEL OF 186 TO 195 INCHES.                                    |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36471       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PALISADES                REGION:  3  |NOTIFICATION DATE: 11/28/1999|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 19:50[EST]|
|   RXTYPE: [1] CE                               |EVENT DATE:        11/28/1999|
+------------------------------------------------+EVENT TIME:        15:45[EST]|
| NRC NOTIFIED BY:  DALE ENGLE                   |LAST UPDATE DATE:  11/28/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RONALD GARDNER       R3      |
|10 CFR SECTION:                                 |                             |
|ADAS 50.72(b)(2)(i)      DEG/UNANALYZED COND    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| "B" TRAIN LOW PRESSURE SAFETY INJECTION (LPSI) FLOW RATES FOUND DEGRADED     |
| DURING SURVEILLANCE TESTING.                                                 |
|                                                                              |
| "WHILE PERFORMING QO-8B (LOW PRESSURE SAFETY INJECTION FLOW TESTING), IT WAS |
| DETERMINED THAT FLOW TO TWO (2) OF FOUR (4) LOOPS (VALVES-MO-3012 & MO-3014  |
| [RIGHT CHANNEL]) WAS INADEQUATE.  THE FLOW RATES WERE BELOW THE DESIGN BASIS |
| FOR ACCIDENT CONDITIONS.  [THIS] CONDITION WAS DISCOVERED DURING             |
| SURVEILLANCE TESTING WHILE THE PLANT WAS IN COLD SHUTDOWN.  THIS IS          |
| REPORTABLE PER 50.72(b)(2)(I)."                                              |
|                                                                              |
| THE DESIGN FLOW RATE IS 1720 GPM.  THE AS-FOUND FLOW RATES THROUGH VALVES    |
| 3012 & 3014 WERE 1650 AND 1500 GPM, RESPECTIVELY.  THE "B" TRAIN LPSI HAS    |
| BEEN DECLARED INOPERABLE PENDING CORRECTIVE ACTION WHICH IS TO BE            |
| DETERMINED.  THE UNIT IS NOT IN A TECH SPEC ACTION STATEMENT IN THAT LPSI IS |
| NOT REQUIRED FOR CURRENT PLANT CONDITIONS.  THE SURVEILLANCE TEST WHICH      |
| IDENTIFIED THIS CONDITION IS PERFORMED EACH REFUELING OUTAGE (APPROXIMATELY  |
| EVERY 18 MONTHS).  THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.         |
+------------------------------------------------------------------------------+