Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for November 9, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           11/08/1999 - 11/09/1999

                              ** EVENT NUMBERS **

36279  36379  36408  36412  36413  36414  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36279       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FERMI                    REGION:  3  |NOTIFICATION DATE: 10/11/1999|
|    UNIT:  [2] [] []                 STATE:  MI |NOTIFICATION TIME: 13:07[EDT]|
|   RXTYPE: [2] GE-4                             |EVENT DATE:        10/11/1999|
+------------------------------------------------+EVENT TIME:        09:59[EDT]|
| NRC NOTIFIED BY:  COSEO                        |LAST UPDATE DATE:  11/08/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN JACOBSON        R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       97       Power Operation  |97       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| VARIOUS SAFETY RELATED EQUIPMENT DECLARED INOPERABLE DUE TO LOSS OF COOLING  |
| TO THE BATTERY CHARGER ROOM .                                                |
|                                                                              |
| Following startup of the Division 2 Residual Heat Removal Service Water      |
| (RHRSW) pumps, it was observed that the Division 2 Emergency Equipment       |
| Service Water (EESW) pump was rotating backwards. Division 2 RHRSW flow was  |
| normal at greater than 9000 gpm. The Division 2 Ultimate Heat Sink (UHS)     |
| service water systems discharge into a common header that can be routed to   |
| the Division 2 UHS cooling tower fans or directly to the reservoir. This     |
| indicates that the Division 2 EESW pump discharge check valve is not fully   |
| closed. The Division 2 EESW pump control was placed in OFF/RESET (normally   |
| in AUTO) at 0959 hrs on 10/11/99. The pump discharge valve was closed to     |
| isolate the flow path and Division 2 EESW has been declared inoperable. This |
| results in Division 2 Emergency Equipment Cooling Water (EECW) being         |
| inoperable. Division 2 EECW provides cooling to the High Pressure Coolant    |
| Injection (HPCI) pump area cooler during accident conditions. Therefore, the |
| HPCI system was declared inoperable(14 day LCO) at 0959 on 10/11/99. HPCI    |
| remains in standby lineup ready for automatic initiation. The Div 2 EECW     |
| also provides cooling to the battery charger room. With the batteries        |
| inoperable they are in an 18 hr LCO.                                         |
|                                                                              |
| The check valve internals have been inspected and preliminary findings       |
| indicate that all parts are intact. The failure of the valve appears to be   |
| caused by a worn disc pin in the valve. Necessary repairs are in progress.   |
|                                                                              |
| The Resident Inspector was notified.                                         |
|                                                                              |
| * * * UPDATE AT 1725 ON 11/8/99, BY PHILIPPON TAKEN BY WEAVER * * *          |
|                                                                              |
| The as found condition and repair of the Emergency Equipment Service Water   |
| (EESW) pump discharge check valve, and its effect on the High Pressure       |
| Coolant Injection (HPCI) room cooler were evaluated.                         |
|                                                                              |
| The EESW system was operable in the as found condition, until it was removed |
| from service for repair.  Based on engineering evaluation of the plant       |
| conditions that existed when EESW was removed from service, the HPCI room    |
| cooler would not have been required to support HPCI operability.  The        |
| evaluation showed that HPCI would be able to operate long enough to complete |
| its intended safety function (mitigate an accident) as defined in the        |
| Updated Final Safety Analysis Report.  Peak room temperature would not have  |
| exceeded Environmental Qualification limits or the HPCI equipment room high  |
| temperature isolation setpoint.  With the room cooler out of service for the |
| EESW check valve repair  HPCI remained capable of automatic initiation and   |
| operation for the duration necessary to mitigate accidents and transients.   |
| Additionally, plant procedures provide directions for bypassing the HPCI     |
| equipment room high temperature trip.  Consequently, there was no loss of    |
| HPCI safety function.  Declaring HPCI inoperable was conservative and based  |
| on initial considerations. Therefore, event notification 36279 is            |
| retracted.                                                                   |
|                                                                              |
| The licensee notified the NRC resident inspector. Notified R3DO (Parker).    |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36379       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 11/01/1999|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 01:50[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        10/31/1999|
+------------------------------------------------+EVENT TIME:        20:30[EST]|
| NRC NOTIFIED BY:  MUTZ                         |LAST UPDATE DATE:  11/08/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MIKE JORDAN          R3      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SAFEGUARDS DEGRADATION RELATED TO MONITORING A CONTROL ACCESS                |
|                                                                              |
| COMPENSATORY MEASURES TAKEN.                                                 |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED.                                     |
|                                                                              |
| SEE HOO LOG FOR ADDITIONAL INFORMATION.                                      |
|                                                                              |
| * * * UPDATE AT 1515 ON 11/8/99 BY DEPUYDT TAKEN BY WEAVER  * * *            |
|                                                                              |
| Further evaluation of this event concluded that the guidance of Generic      |
| Letter 91-03,  Reporting of Safeguards Events , Enclosure 1, was applicable. |
| Specifically, Enclosure 1 states that a failed compensatory measure that     |
| fails after being successfully established as an effective compensatory      |
| measure for a degraded security system is a loggable event.                  |
|                                                                              |
| Therefore, in keeping with the Guidance of GL 91-03, Event #36379 is         |
| retracted as an event that must be reported within 1 hour under 10 CFR       |
| 73.71, and will be instead recorded as a loggable event.                     |
|                                                                              |
| The licensee informed the NRC resident inspector.  The Operations Center     |
| notified the R3DO (Parker).                                                  |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36408       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 11/06/1999|
|    UNIT:  [1] [2] []                STATE:  WI |NOTIFICATION TIME: 21:46[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        11/06/1999|
+------------------------------------------------+EVENT TIME:        18:44[CST]|
| NRC NOTIFIED BY:  PHILLIP SHORT                |LAST UPDATE DATE:  11/08/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JAMES CREED          R3      |
|10 CFR SECTION:                                 |                             |
|AMED 50.72(b)(2)(v)      OFFSITE MEDICAL        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| INJURED POTENTIALLY CONTAMINATED WORKER TRANSPORTED TO LOCAL HOSPITAL        |
|                                                                              |
| "A WORKER SLIPPED AND FELL IN THE LAUNDRY ROOM.  AN AMBULANCE WAS CALLED DUE |
| TO A POSSIBLE HIP INJURY.  A COMPLETE FRISK OF THE INDIVIDUAL WAS NOT ABLE   |
| TO BE PERFORMED PRIOR TO TRANSPORTING OFFSITE TO A LOCAL HOSPITAL.  THE      |
| INJURED PERSON IS BEING CONSIDERED POTENTIALLY CONTAMINATED.  A RADIATION    |
| PROTECTION TECHNICIAN IS ACCOMPANYING THE INJURED PERSON TO THE HOSPITAL."   |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
|                                                                              |
| * * * RETRACTION 0953 11/8/1999 FROM MEYER TAKEN BY STRANSKY * * *           |
|                                                                              |
| "This Notification is a retraction of a 4-hour Notification that was made on |
| 11/6/99. The Notification was issued yesterday when a potentially            |
| contaminated worker was transported to a local hospital. At the time of the  |
| notification, it was not known whether the worker or the lab coat she was    |
| wearing was contaminated. The Radiation Protection Technician who            |
| accompanied her determined that the worker and the lab coat were not         |
| contaminated. Therefore, the Notification made on 11/6/99 is retracted."     |
|                                                                              |
| The NRC resident inspector has been informed of this retraction by the       |
| licensee. Notified R3DO (Parker).                                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   36412       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  DEACONESS BILLINGS CLINIC            |NOTIFICATION DATE: 11/08/1999|
|LICENSEE:  DEACONESS BILLNGS CLINIC             |NOTIFICATION TIME: 17:16[EST]|
|    CITY:  BILLINGS                 REGION:  4  |EVENT DATE:        11/03/1999|
|  COUNTY:                            STATE:  MT |EVENT TIME:        12:00[MST]|
|LICENSE#:  25-01051-01           AGREEMENT:  N  |LAST UPDATE DATE:  11/08/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |PHIL HARRELL         R4      |
|                                                |WAYNE HODGES         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  DAVID SWITZER                |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|LADM 35.33(a)            MED MISADMINISTRATION  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MEDICAL MISADMINISTRATION                                                    |
|                                                                              |
| Only two of three I-131 pills were administered to a patient on 11/3/99.     |
| The intended dose was 200 mCi, and approximately 148 mCi were delivered.     |
| This was an ablative thyroid dose for cancer.  The patient's attending       |
| physician has been notified of the error and the patient will be contacted   |
| as soon as possible.  The reason for the error was that two pills came in    |
| one vial and only one of those pills was removed and given to the patient.   |
| The other pill remained in the vial and was discovered today 11/8/99, at     |
| 1300 PST.                                                                    |
|                                                                              |
| The patient will be monitored and treated as necessary.                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36413       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAN ONOFRE               REGION:  4  |NOTIFICATION DATE: 11/08/1999|
|    UNIT:  [1] [2] [3]               STATE:  CA |NOTIFICATION TIME: 17:24[EST]|
|   RXTYPE: [1] W-3-LP,[2] CE,[3] CE             |EVENT DATE:        11/08/1999|
+------------------------------------------------+EVENT TIME:        13:45[PST]|
| NRC NOTIFIED BY:  G. L. PLUMLEE                |LAST UPDATE DATE:  11/08/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |PHIL HARRELL         R4      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SAFEGUARDS SYSTEM DEGRADATION RELATED TO AREA BOUNDARY. IMMEDIATE            |
| COMPENSATORY ACTIONS TAKEN UPON DISCOVERY. THE NRC RESIDENT INSPECTOR WILL   |
| BE INFORMED BY THE LICENSEE                                                  |
|                                                                              |
| CONTACT THE NRC OPERATIONS CENTER FOR ADDITIONAL DETAILS.                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36414       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 11/08/1999|
|    UNIT:  [1] [] []                 STATE:  WI |NOTIFICATION TIME: 18:30[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        11/08/1999|
+------------------------------------------------+EVENT TIME:        16:00[CST]|
| NRC NOTIFIED BY:  MIKE MEYER                   |LAST UPDATE DATE:  11/08/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MICHAEL PARKER       R3      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ESF ACTUATION - SAFETY INJECTION SIGNAL INADVERTENTLY INSERTED DURING        |
| TESTING                                                                      |
|                                                                              |
| While performing post maintenance testing on 1P-ISA (Safety Injection Pump), |
| an inadvertent ESF occurred.  The 'A' Safety Injection Train actuated on     |
| Unit 1 after the electrician installed a jumper which was intended to        |
| simulate an Auto Start signal for 1P-ISA.  The jumper terminals appear to    |
| have been incorrectly identified in the work plan.  All systems started as   |
| designed.  The SI pumps did not start because they were in pull-to-lock per  |
| procedure for the existing plant conditions.  The following                  |
| components/activations occurred:  Aux feed pump start, EDG start (Train A),  |
| and containment isolation.  Because the affected unit was defueled, systems  |
| that would normally inject into the reactor coolant system were tagged out.  |
| There was no ECCS discharge.  Service water was momentarily isolated to      |
| Spent Fuel Pool Cooling resulting in spent fuel pool temperature increasing  |
| slightly.  Bulk spent fuel pool temperature remained at approximately 85�F.  |
| Current calculated time to boil is 19 hours.                                 |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+