Event Notification Report for November 2, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 11/01/1999 - 11/02/1999 ** EVENT NUMBERS ** 35790 36284 36372 36379 36380 36381 36382 36383 36384 +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 35790 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 06/03/1999| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 14:44[EDT]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 06/02/1999| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 16:30[CDT]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 11/01/1999| | CITY: PADUCAH REGION: 3 +-----------------------------+ | COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION | |LICENSE#: GDP-1 AGREEMENT: Y |DAVID HILLS R3 | | DOCKET: 0707001 |DON COOL NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: THOMAS WHITE | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |OCBA 76.120(c)(2)(i) ACCID MT EQUIP FAILS | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THREE SPRINKLER SYSTEMS DECLARED INOPERABLE DUE TO CORRODED HEADS (24-hour | | report) | | | | "On 06/02/99 at 1630 CDT, the Plant Shift Superintendent (PSS) was notified | | that numerous sprinkler heads were corroded, affecting 16 sprinkler systems | | in C-337 and one system in C-333, such that the ability of the sprinklers to | | flow sufficient water was called into question. Subsequently, these | | sprinkler systems were declared inoperable, and TSR-required actions | | establishing roving fire patrols were initiated. This deficiency was | | detected during scheduled system inspections conducted by Fire Protection | | personnel. Currently, functionality of the sprinkler heads has not been | | fully evaluated by Fire Protection personnel, and the remaining cascade | | buildings are currently being inspected, and if necessary, this report will | | be updated to identify any additional areas. It has been determined that | | this event is reportable under 10CFR76.120(c)(2) as an event in which | | equipment is disabled or fails to function as designed." The NRC resident | | inspector has been notified of this event. | | | | * * * UPDATE AT 1022 EDT ON 06/04/99 FROM CAGE TO TROCINE * * * | | | | "Two sprinkler heads on system D-1 in C-337 and two sprinkler heads on | | system 27 in C-335 were identified to also be corroded. These were | | identified to the PSS on 06/03/99 at 1600 CDT and 1601 CDT, respectively, | | and determined to require an update to this report by the PSS. It has been | | determined that this event is reportable under 10CFR76.120(c)(2) as an event | | in which equipment is disabled or fails to function as designed." Paducah | | personnel notified the NRC resident inspector of this update. The NRC | | operations officer notified the R3DO (Hills) and NMSS EO (Combs). | | | | * * * UPDATE AT 2152 EDT ON 06/17/99 FROM WALKER TO POERTNER * * * | | | | "Three sprinkler heads on system C-15 and five sprinkler heads on system B-8 | | in C-333 were identified to also be corroded. The PSS was notified of this | | condition at 1300 CDT on 06/17/99 and determined that an update to this | | report was required. It has been determined that this event is reportable | | under 10CFR76.120(c)(2) as an event in which equipment is disabled or fails | | to function as designed." Paducah personnel notified the NRC resident | | inspector of this update. The NRC operations officer notified the R3DO | | (Madera). | | | | * * * UPDATE 1440 EDT 6/18/1999 FROM UNDERWOOD TAKEN BY STRANSKY * * * | | | | "Two sprinkler heads on system C-15 and one sprinkler head on system B-8 in | | C-333 were identified to have corrosion. The PSS was notified of this | | condition at 1350 CDT on 06/18/99. The area of the fire patrol for system | | C-15 was expanded to include the two heads identified as corroded. The one | | head on system B-8 was in the area already being patrolled. The PSS | | determined that an update to this report was required." The NRC resident | | inspector has been informed of this update. Notified R3DO (Madera). | | | | * * * UPDATE 1315 EDT 6/25/1999 FROM WALKER TAKEN BY STRANSKY * * * | | | | "Two sprinkler heads on system D-8 and three sprinkler heads on system D-7 | | in C-337 were identified to have corrosion. The PSS was notified of the | | condition on system D-8 at 0125 CDT on 06/25/99 and at 1019 CDT on 06/25/99 | | for system D-7. Both systems were immediately declared inoperable and LCO | | fire patrol actions were implemented. It was determined that an update to | | this report was required." The NRC resident inspector has been informed of | | this update. Notified R3DO (Jordan). | | | | * * * UPDATE 2119 EDT 7/30/1999 FROM CAGE TAKEN BY STRANSKY * * * | | | | "Five sprinkler heads and one sprinkler piping tee on C-337 system D-7 were | | identified to have corrosion. The PSS was notified of these corroded system | | parts and declared the system inoperable at 0931 CDT on 07/30/99. LCO | | required fire patrols of the affected area were initiated. The PSS | | determined that an update to this event report was required." The NRC | | resident inspector has been informed of this update. Notified R3DO | | (Wright). | | | | * * * UPDATE 1655 EDT 7/31/1999 FROM WHITE TAKEN BY STRANSKY * * * | | | | "Two sprinkler heads on C-337 System D-1 were identified to have corrosion. | | The PSS was notified of these corroded system parts and declared the system | | inoperable at 1155 CDT on 7/31/99. LCO required fire patrols of the | | affected area were initiated. The PSS determined that an update to this | | report was required." The NRC resident inspector has been informed of this | | update. Notified R3DO (Wright). | | | | * * * UPDATE 1546 EDT 8/10/1999 FROM WHITE TAKEN BY STRANSKY * * * | | | | "Two sprinkler heads on C-337 system C-15 were identified to have corrosion. | | The PSS was notified of these corroded system parts and declared the system | | inoperable at 1130 CDT on 8/10/99. LCO required fire patrols of the | | affected area were initiated. The PSS determined that an update to this | | report was required." The NRC resident inspector has been informed of this | | update. Notified R3DO (Burgess). | | | | * * * UPDATE AT 1154 EDT 8/22/99 FROM WALKER TO POERTNER * * * | | | | Four adjacent sprinkler heads on C-333 System B-1 were identified to have | | corrosion. The PSS was notified of the corroded system parts and declared | | the system inoperable at 0918 CDT on 8/22/99. LCO required fire patrols | | were initiated. The PSS determined that an update to this report was | | required. It has been determined that this event is reportable under | | 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to | | function as designed. The NRC resident inspector will be notified. The NRC | | operations officer notified the R3DO (Clayton). | | | | * * * UPDATE 2015 EDT ON 8/28/99 FROM W. F. GAGE TO S. SANDIN * * * | | | | "Two adjacent sprinkler heads on C-337 System D-11 were identified to have | | corrosion. The PSS was notified of these corroded system parts and declared | | the system inoperable at 1420 CDT on 8/28/99. LCO required fire patrols of | | the affected area were initiated. The PSS determined that an update to this | | report was required." | | Paducah personnel informed the NRC resident inspector. The NRC operations | | officer notified the R3DO (Leach) and NMSS EO (Piccone). | | | | * * * UPDATE 2037 EDT ON 8/29/99 FROM KEVIN BEASLEY TO S. SANDIN * * * | | | | "Two adjacent sprinkler heads on C-337 System D-15 were identified to have | | corrosion and the PSS declared the system inoperable at 0925 [CDT] on | | 8/29/99. Also two adjacent heads on C-337 System D-10 were identified to | | have corrosion and the PSS declared the system inoperable at 1450. LCO | | required fire patrols for both of the affected areas were initiated in the | | time frame required by TSR. The PSS determined that an update to this | | report was required." Paducah personnel informed the NRC resident | | inspector. The NRC operations officer notified the R3DO (Leach) and NMSS EO | | (Piccone). | | | | * * * UPDATE AT 0930 EDT ON 9/1/99 BY ERIC WALKER TO FANGIE JONES * * * | | | | Add two adjacent sprinkler heads on C-337 D-14. Paducah personnel informed | | the NRC Resident Inspector. The NRC operations officer notified the R3DO | | (David Hills) and NMSS (Robert Pierson). | | | | * * * UPDATE AT 1133 EDT ON 9/8/99 BY TOM WHITE TO FANGIE JONES * * * | | | | Add two adjacent sprinkler heads on C-331 System 26, system declared | | inoperable at 2155 CDT on 9/7/99. An LCO required fire patrol for the | | affected area was initiated in the time frame required by the TSR. Paducah | | personnel informed the NRC Resident Inspector. The NRC operations officer | | notified the R3DO (Monte Phillips) and NMSS (Josie Piccone). | | | | * * * UPDATE AT 0948 ON 9/30/99 BY ERIC WALKER TO DOUG WEAVER * * * | | | | Add two adjacent sprinkler heads on C-333 System B-15 were identified to | | have corrosion and the PSS declared the system inoperable at 0815 CDT on | | 9/30/99. An LCO required fire patrol for the affected area was initiated in | | the time frame required by the TSR. The PSS determined that an update to | | this report was required. | | Paducah personnel informed the NRC resident inspector. The NRC operations | | officer notified the R3DO (Vegel) and NMSS (Cool). | | | | * * * UPDATE AT 1600 ON 10/13/99 BY WALKER TO GOULD * * * | | | | Two adjacent sprinkler heads on C-333 System A-11 were Identified to have | | corrosion and the PSS declared the system inoperable at 1307 CDT on | | 10/13/99. An LCO required fire patrol for the affected area was initiated | | in the time frame required by the TSR, The PSS determined that an update to | | this report was required. Paducah personnel informed the NRC resident | | inspector. The NRC operations officer notified the R3DO (Madera) and NMSS | | (Moore). | | | | * * * UPDATE AT 1520 ON 10/19/99 FROM UNDERWOOD TAKEN BY STRANSKY * * * | | | | Six sprinkler heads on C-337 System D-16 were identified to have corrosion | | and the PSS declared the system inoperable at 1052 CDT on 10/19/99. An LCO | | required fire patrol for the affected area was initiated in the time frame | | required by the TSR. The PSS determined that an update to this report was | | required. The NRC resident inspector has been informed of this update. The | | NRC Operations Officer notified R3DO (Jorgensen). | | | | * * * UPDATE AT 2140 ON 10/19/99 FROM WALKER TAKEN BY STRANSKY * * * | | | | Seven sprinkler heads on C-337 System A-7 were identified to have corrosion, | | and another four had been painted over. In addition, three adjacent | | sprinkler heads on C-337 System A-8 were identified to have corrosion. The | | PSS declared the systems inoperable at 1900 CDT on 10/19/99. An LCO | | required fire patrols for the affected areas were initiated in the time | | frame required by the TSR. The PSS determined that an update to this report | | was required. The NRC resident inspector has been informed of this update. | | The NRC Operations Officer notified R3DO (Wright). | | | | * * * UPDATE AT 1713 ON 10/21/99 FROM CAGE TAKEN BY JOLLIFFE * * * | | | | Four sprinkler heads on C-337 System A-5, twelve sprinkler heads on C-337 | | System A-8, three sprinkler heads on C-337 System A-9, and six sprinkler | | heads on C-337 System B-8 were identified to have corrosion. On 10/21/99, | | the PSS declared System A-5 and A-9 inoperable at 1028 CDT, System A-8 | | inoperable at 1227 CDT and System B-8 inoperable at 1406 CDT. An LCO | | required fire patrol for the affected areas was initiated in the time frame | | required by the TSR.. The PSS determined that an update to this report was | | required. The NRC Resident Inspector has been informed of this update. The | | NRC Operations Officer notified the R3DO Bruce Jorgensen. | | | | * * * UPDATE AT 2128 ON 10/22/99 FROM ERIC WALKER TAKEN BY JOLLIFFE * * * | | | | At 1400 CDT on 10/22/99, the PSS was notified that numerous corroded | | sprinkler heads were discovered in C-337 on sprinkler systems B-1, B-3, B-5, | | B-6, B-7, B-11 and D-17. Due to the number of systems called into question, | | the PSS declared all of the sprinkler systems in C-337 on the cell floor (a | | total of 66 systems) inoperable and TSR required actions establishing roving | | fire patrols were initiated within the required time frame. The PSS | | determined that an update to this report was required. It has been | | determined that this event Is reportable under 10CFR76.120(c)(2) as an event | | in which equipment is disabled or fails to function as designed. | | The NRC Resident lnspector has been informed of this update. The NRC | | Operations Officer notified the R3DO Bruce Jorgensen. | | | | * * * UPDATE AT 1239 ON 10/24/99 FROM TOM WHITE TAKEN BY JOLLIFFE * * * | | | | At 1200 CDT on 10/23/99, the PSS was notified that numerous corroded | | sprinkler heads were discovered in C-337 on sprinkler systems B-13 and B-14 | | on the ground floor, The PSS declared these systems inoperable and TSR | | required actions establishing roving fire patrols were initiated within the | | required time frame. At 1600 CDT on 10/23/99, the PSS was notified that | | numerous corroded sprinkler heads were discovered in C-337 on sprinkler | | systems A-16, B-12, C-8, C-12, C-15, D-5 and D-8 on the cell floor, These | | systems have already been declared inoperable and fire patrols are already | | being performed. The PSS determined that an update to this report was | | required. It has been determined that this event is reportable under | | I0CFR76.120(c)(2) as an event in which equipment is disabled or fails to | | function as designed. The NRC resident inspector has been informed of this | | update. The NRC Operations Officer notified the R3DO Bruce Jorgensen. | | | | * * * UPDATE AT 1117 ON 10/25/99 FROM W. F. CAGE TAKEN BY SANDIN * * * | | | | At 1940 CDT on 10/24/99, the PSS was notified that numerous corroded | | sprinkler heads had been discovered on High Pressure Fire Water systems C-4, | | C-5, C-6 and C-8, located in the C-337 building. These systems had | | previously been declared inoperable, and fire patrols were already being | | performed at the time of discovery. The PSS determined that an update to | | this report was required. It has been determined that this event is | | reportable under 10CFR76.120(c)(2) as an event in which equipment is | | disabled or fails to function as designed. | | The NRC Resident Inspector has been notified of this update. The NRC | | Operations Officer notified R3DO (Lanksbury) and NMSS (Brain Smith). | | | | * * * UPDATE AT 2235 ON 10/27/99 BY WHITE TAKEN BY MACKINNON * * * | | | | At 1517 CDT on 10/27/99, the PSS was notified that 9 corroded sprinkler | | heads had been discovered on High Pressure Fire Water System A-12 located in | | the C-333 building. This system has been declared inoperable and fire | | patrols have been initiated. The PSS determined that an update to this | | report was required. The NRC Resident Inspector has been notified of this | | update. The NRC Operations Officer notified R3DO (Jordan) and NMSS EO | | (Hickey). | | | | * * * UPDATE AT 2150 ON 10/30/99 BY UNDERWOOD TAKEN BY WEAVER * * * | | | | At 1950 CDT on 10/30/99, the PSS was notified that numerous corroded | | sprinkler heads had been discovered on High Pressure Fire Water Systems A-5, | | A-9, A-11, C-5, and C-7 in the C-333 building. Reference ATR-1 1999-6699 | | and 6702. These systems have been declared inoperable and fire patrols have | | been initiated. Also, due to the number of inoperable sprinkler heads, the | | remaining systems on the cell floor of C-333 were called into question and | | declared inoperable. Fire patrols for the entire cell floor have been | | initialed. The PSS determined that an update to this report was required. | | The NRC Resident Inspector has been notified of this update. The NRC | | Operations Officer notified R3DO (Jordan) and NMSS EO (Hickey). | | | | * * * UPDATE AT 2111 ON 10/31/99 BY UNDERWOOD TAKEN BY WEAVER * * * | | | | At 1412 CDT on 10/31/99, the PSS was notified that five corroded sprinkler | | heads had been discovered on High Pressure Fire Water System 9 in the C-335 | | building. There were two adjacent corroded heads discovered in two separate | | locations and a third individual head at a different location. The system | | was declared inoperable and fire patrols were initiated. The corroded heads | | have since been replaced and the system returned to operable status. The | | NRC Resident Inspector was notified of this update. The NRC Operations | | Officer notified R3DO (Jordan) and NMSS EO (Hickey). | | | | * * * UPDATE AT 2121 ON 11/01/99 BY KEVIN BEASLEY TAKEN BY JOLLIFFE * * * | | | | At 0930 CST on 11/01/99, the PSS was notified that three corroded sprinkler | | heads had been discovered on the High Pressure Fire Water System B-4 in the | | C-337 building. Two of these sprinkler heads are adjacent. Two adjacent | | corroded sprinkler heads were also discovered on the High Pressure Fire | | Water System B-5 in the C-337 building. These systems were declared | | inoperable and fire patrols were initiated. Work has been initiated to | | replace the subject heads. The NRC Resident Inspector has been notified of | | this update. The NRC Operations Officer notified the R3DO Jim Creed. | +------------------------------------------------------------------------------+ !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 36284 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 10/13/1999| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 02:50[EDT]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 10/12/1999| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 02:55[CDT]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 11/01/1999| | CITY: PADUCAH REGION: 3 +-----------------------------+ | COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION | |LICENSE#: GDP-1 AGREEMENT: Y |JOHN MADERA R3 | | DOCKET: 0707001 |BRIAN SMITH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: J. UNDERWOOD | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NLTR LICENSEE 24 HR REPORT | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | 24 HOUR REPORT - VALID ALARM ON PRIMARY CONDENSATE, A SAFETY SYSTEM | | | | "At 0225 CDT on 10/12/99, the PSS office was notified that a Primary | | Condensate alarm was received on the C-360 position 3 autoclave Water | | Inventory Control System (WICS). The WICS is required to be operable while | | heating in mode 5 according to TSR 2.1.4.3. The autoclave was checked | | according to the alarm response procedure and subsequently removed from | | service and declared inoperable by the Plant Shift Superintendent. | | Troubleshooting was initiated and is continuing in order to determine the | | reason for the alarm. | | | | "The safety system actuation is reportable to the NRC as required by Safety | | Analysis Report, section 6.9, table 1, criteria J.2, Safety System actuation | | due to a valid signal as a 24-hour event notification." | | | | The NRC Resident Inspector has been notified of this event. | | | | * * * UPDATE AT 1551 ON 11/01/99 BY FRANK CAGE TO JOLLIFFE * * * | | | | "Troubleshooting and testing by System Engineering has determined that this | | actuation was caused by a short circuit of the primary condensate WICS | | wiring to its protective conduit. Agitation of the conduit resulted in | | repeated false alarms on the WICS. Given this finding and the fact that the | | actuation occurred at a point in the heat cycle beyond the initial heatup | | and triple point when the maximum condensate is being produced, indicate | | that the actuation signal was not a result of water backed up in the drain | | line, which the WICS is designed to protect against. Thus, this is an | | invalid signal. Actuations caused by invalid signals are not reportable to | | the NRC." | | | | Therefore, this event is being retracted. | | | | The NRC Resident Inspector has been notified of this update. The NRC | | Operations Officer notified the R3DO Jim Creed and the NMSS EO John Hickey. | | | | PGDP Problem Report #ATR-99-6175, PGDP Event Report #PAD-1999-112. | +------------------------------------------------------------------------------+ !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Hospital |Event Number: 36372 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: LIBERTY HOSPITAL |NOTIFICATION DATE: 10/29/1999| |LICENSEE: LIBERTY HOSPITAL |NOTIFICATION TIME: 10:37[EDT]| | CITY: LIBERTY REGION: 3 |EVENT DATE: 10/27/1999| | COUNTY: STATE: MO |EVENT TIME: [CDT]| |LICENSE#: AGREEMENT: N |LAST UPDATE DATE: 11/01/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |MIKE JORDAN R3 | | | | +------------------------------------------------+ | | NRC NOTIFIED BY: TOM BROWN | | | HQ OPS OFFICER: BOB STRANSKY | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |LADM 35.33(a) MED MISADMINISTRATION | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | MEDICAL MISADMINISTRATION | | | | On 10/27/1999, a patient was to receive a dose of 120 Gy (12,000 rad) by way | | of implanted palladium seeds. The seeds that were ordered and delivered to | | the hospital had an activity of 1.05 millicuries each, instead of 1.4 | | millicuries, which would have been needed to obtain the prescribed dose. The | | physicians treating the patient made a decision to implant the seeds anyway, | | resulting in a dose of 90 Gy, and to supplement the dose by external beam. | | However, the written prescription kept in the hot lab was not annotated to | | include this change in treatment. | | | | Therefore, this condition is being reported as a medical misadministration, | | in that the actual dose was 25% less than that prescribed. The licensee will | | contact the NRC Region III office regarding this issue. | | | | * * * UPDATE AT 1601 ON 11/01/99 BY TOM BROWN TO JOLLIFFE * * * | | | | The licensee desires to retract this event since palladium is regulated by | | the state of Missouri and not the NRC. | | | | The NRC Operations Officer notified the R3DO Jim Creed and NMSS EO John | | Hickey. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 36379 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: COOK REGION: 3 |NOTIFICATION DATE: 11/01/1999| | UNIT: [1] [] [] STATE: MI |NOTIFICATION TIME: 01:50[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 10/31/1999| +------------------------------------------------+EVENT TIME: 20:30[EST]| | NRC NOTIFIED BY: MUTZ |LAST UPDATE DATE: 11/01/1999| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |MIKE JORDAN R3 | |10 CFR SECTION: | | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SAFEGUARDS DEGRADATION RELATED TO MONITORING A CONTROL ACCESS | | | | COMPENSATORY MEASURES TAKEN. | | | | THE NRC RESIDENT INSPECTOR WAS NOTIFIED. | | | | SEE HOO LOG FOR ADDITIONAL INFORMATION. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 36380 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: CRMI |NOTIFICATION DATE: 11/01/1999| |LICENSEE: LAS PIEDRAS CONSTRUCTION |NOTIFICATION TIME: 08:55[EST]| | CITY: UTUADO REGION: 2 |EVENT DATE: 10/30/1999| | COUNTY: STATE: PR |EVENT TIME: 09:00[EST]| |LICENSE#: 52-25125-01 AGREEMENT: N |LAST UPDATE DATE: 11/01/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |MARK LESSER R2 | | |FRITZ STURZ EO NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: RHOE (CONSULTANT) | | | HQ OPS OFFICER: CHAUNCEY GOULD | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | STOLEN MOISTURE DENSITY GAUGE | | | | A CPN MODEL MC-3 SERIAL NUMBER M-351102935 CONTAINING 10 MILLICURIES OF | | CS-137 AND 50 MILLICURIES OF AM-241 WAS STOLEN FROM LAS PIEDRAS CONSTRUCTION | | COMPANY'S FACILITIES IN UTUADO, PR. THE LOCAL POLICE DEPARTMENT WAS | | NOTIFIED AND THERE WILL BE A PRESS RELEASE. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 36381 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 11/01/1999| | UNIT: [] [2] [] STATE: AL |NOTIFICATION TIME: 09:38[EST]| | RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 11/01/1999| +------------------------------------------------+EVENT TIME: 06:30[CST]| | NRC NOTIFIED BY: WHITE |LAST UPDATE DATE: 11/01/1999| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |MARK LESSER R2 | |10 CFR SECTION: | | |ADAS 50.72(b)(2)(i) DEG/UNANALYZED COND | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N N 0 Refueling |0 Refueling | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | STEAM GENERATOR EDDY CURRENT INSPECTION DETECTED TUBE DEGRADATION | | | | DURING EDDY CURRENT INSPECTION, THE INSPECTION RESULTS FROM STEAM GENERATORS | | "2A" AND "2C" WERE IDENTIFIED AS BEING IN THE C-3 INSPECTION CATEGORY PER | | TECHNICAL SPECIFICATIONS. EDDY CURRENT INSPECTIONS ARE CONTINUING AND IT IS | | ANTICIPATED THE "2B" WILL LATER BE IDENTIFIED AS BEING IN THE C-3 INJECTION | | CATEGORY. THE TUBE DEGRADATION WILL REQUIRED TUBE PLUGGING. STEAM | | GENERATORS MAY BE REPLACED DURING THE NEXT UNIT REFUELING. TO DATE THE | | PERCENTAGE OF DEFECTIVE TUBES IN S/G "A" - 2.9%, S/G "B" - 0.3% AND S/G "C" | | - 2.3%. | | | | THE NRC RESIDENT INSPECTOR WAS NOTIFIED. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 36382 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: MCGUIRE REGION: 2 |NOTIFICATION DATE: 11/01/1999| | UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 16:12[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 11/01/1999| +------------------------------------------------+EVENT TIME: 15:41[EST]| | NRC NOTIFIED BY: CHUCK RARY |LAST UPDATE DATE: 11/01/1999| | HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |MARK LESSER R2 | |10 CFR SECTION: | | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Cold Shutdown |0 Cold Shutdown | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - PLANT SECURITY EVENT - | | | | Unescorted plant access granted inappropriately. Compensatory measures were | | immediately taken upon discovery. The licensee plans to notify the NRC | | Resident Inspector. Contact the NRC Operations Officer for additional | | details. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 36383 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: FORT BLISS, TEXAS |NOTIFICATION DATE: 11/01/1999| |LICENSEE: FORT BLISS, TEXAS |NOTIFICATION TIME: 16:31[EST]| | CITY: REGION: 4 |EVENT DATE: 11/01/1999| | COUNTY: STATE: TX |EVENT TIME: 11:30[CST]| |LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 11/01/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |CLAUDE JOHNSON R4 | | |JAMES CREED R3 | +------------------------------------------------+JOHN HICKEY NMSS | | NRC NOTIFIED BY: BRIAN BRENISER | | | HQ OPS OFFICER: DICK JOLLIFFE | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |BAE1 20.2202(b)(1) PERS OVEREXPOSURE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - POTENTIAL CONTAMINATION EVENT - | | | | At 1130 CST on 11/01/99, a soldier opened and then closed four chemical | | agent detectors to determine the presence of their 250 millicurie | | Americium-241 sources. After closing the fourth detector, the soldier | | complained of itching and burning of her skin. She was sent to the fort | | medical hospital to determine if she was contaminated. | | | | * * * UPDATE AT 1921 ON 11/01/99 FROM MAJOR COOPER TO JOLLIFFE * * * | | | | Fort Bliss Hospital determined that the soldier was not contaminated. The | | NRC Operations Officer notified Region 4 (Linda Howell) and R3DO (Jim | | Creed). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 36384 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: MALLINCKRODT PHARMACY |NOTIFICATION DATE: 11/01/1999| |LICENSEE: MALLINCKRODT PHARMACY |NOTIFICATION TIME: 16:40[EST]| | CITY: PINE BROOK REGION: 1 |EVENT DATE: 11/01/1999| | COUNTY: STATE: NJ |EVENT TIME: 15:30[EST]| |LICENSE#: 24-04206-14MD AGREEMENT: N |LAST UPDATE DATE: 11/01/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |MOHAMED SHANBAKY R1 | | |JOHN HICKEY NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: JASON WILLMAN | | | HQ OPS OFFICER: DICK JOLLIFFE | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |BAE1 20.2202(b)(1) PERS OVEREXPOSURE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - HANDLES OF TRANSPORT PACKAGES CONTAMINATED - | | | | Carlos Express Company transported two packages of limited quantities of | | technetium-99m from St Joseph Hospital and Medical Center in Patterson, NJ, | | to Mallinckrodt Pharmacy in Pine Brook, NJ. An NRC Region 1 inspector | | surveyed the packages upon arrival in Pine Brook and found two hot spots on | | the packages (2 mR/hr on each package handle). Wipe tests determined | | 130,000 DPM on one handle and 100,000 DPM on the second handle. There was | | no radiation above background on the transport truck or the driver. The | | licensee isolated the packages, notified Carlos Express and St Joseph | | Hospital and Medical Center, and is continuing to investigate this incident. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021