Event Number: 36381
Facility: FARLEY
Region: 2     State: AL
Unit: [] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: WHITE
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 11/01/1999
Notification Time: 09:38 [ET]
Event Date: 11/01/1999
Event Time: 06:30 [CST]
Last Update Date: 11/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
MARK LESSER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 0 Refueling
Event Text
STEAM GENERATOR EDDY CURRENT INSPECTION DETECTED TUBE DEGRADATION

DURING EDDY CURRENT INSPECTION, THE INSPECTION RESULTS FROM STEAM GENERATORS "2A" AND "2C" WERE IDENTIFIED AS BEING IN THE C-3 INSPECTION CATEGORY PER TECHNICAL SPECIFICATIONS. EDDY CURRENT INSPECTIONS ARE CONTINUING AND IT IS ANTICIPATED THE "2B" WILL LATER BE IDENTIFIED AS BEING IN THE C-3 INJECTION CATEGORY. THE TUBE DEGRADATION WILL REQUIRED TUBE PLUGGING. STEAM GENERATORS MAY BE REPLACED DURING THE NEXT UNIT REFUELING. TO DATE THE PERCENTAGE OF DEFECTIVE TUBES IN S/G "A" - 2.9%, S/G "B" - 0.3% AND S/G "C" - 2.3%.

THE NRC RESIDENT INSPECTOR WAS NOTIFIED.


Power Reactor
Event Number: 36382
Facility: MCGUIRE
Region: 2     State: NC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: CHUCK RARY
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/01/1999
Notification Time: 16:12 [ET]
Event Date: 11/01/1999
Event Time: 15:41 [EST]
Last Update Date: 11/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
MARK LESSER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
2 N Y 100 Power Operation 100 Power Operation
Event Text
- PLANT SECURITY EVENT -

Unescorted plant access granted inappropriately. Compensatory measures were immediately taken upon discovery. The licensee plans to notify the NRC Resident Inspector. Contact the NRC Operations Officer for additional details.


General Information or Other
Event Number: 36383
Rep Org: FORT BLISS, TEXAS
Licensee: FORT BLISS, TEXAS
Region: 4
City:   State: TX
County:
License #:
Agreement: Y
Docket:
NRC Notified By: BRIAN BRENISER
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/01/1999
Notification Time: 16:31 [ET]
Event Date: 11/01/1999
Event Time: 11:30 [CST]
Last Update Date: 11/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2202(b)(1) - PERS OVEREXPOSURE/TEDE >= 5 REM
Person (Organization):
CLAUDE JOHNSON (R4)
JAMES CREED (R3)
JOHN HICKEY (NMSS)
Event Text
- POTENTIAL CONTAMINATION EVENT -

At 1130 CST on 11/01/99, a soldier opened and then closed four chemical agent detectors to determine the presence of their 250 millicurie Americium-241 sources. After closing the fourth detector, the soldier complained of itching and burning of her skin. She was sent to the fort medical hospital to determine if she was contaminated.

* * * UPDATE AT 1921 ON 11/01/99 FROM MAJOR COOPER TO JOLLIFFE * * *

Fort Bliss Hospital determined that the soldier was not contaminated. The NRC Operations Officer notified Region 4 (Linda Howell) and R3DO (Jim Creed).


General Information or Other
Event Number: 36384
Rep Org: MALLINCKRODT PHARMACY
Licensee: MALLINCKRODT PHARMACY
Region: 1
City: PINE BROOK   State: NJ
County:
License #: 24-04206-14MD
Agreement: N
Docket:
NRC Notified By: JASON WILLMAN
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/01/1999
Notification Time: 16:40 [ET]
Event Date: 11/01/1999
Event Time: 15:30 [EST]
Last Update Date: 11/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MOHAMED SHANBAKY (R1)
JOHN HICKEY (NMSS)
Event Text
- HANDLES OF TRANSPORT PACKAGES CONTAMINATED -

Carlos Express Company transported two packages of limited quantities of technetium-99m from St Joseph Hospital and Medical Center in Patterson, NJ, to Mallinckrodt Pharmacy in Pine Brook, NJ. An NRC Region 1 inspector surveyed the packages upon arrival in Pine Brook and found two hot spots on the packages (2 mR/hr on each package handle). Wipe tests determined 130,000 DPM on one handle and 100,000 DPM on the second handle. There was no radiation above background on the transport truck or the driver. The licensee isolated the packages, notified Carlos Express and St Joseph Hospital and Medical Center, and is continuing to investigate this incident.


General Information or Other
Event Number: 36405
Rep Org: ILLINOIS DEPT OF NUCLEAR SAFETY
Licensee:
Region: 3
City:   State: IL
County:
License #:
Agreement: Y
Docket:
NRC Notified By: BRUCE SANZA
HQ OPS Officer: STEVE SANDIN
Notification Date: 11/05/1999
Notification Time: 17:06 [ET]
Event Date: 11/01/1999
Event Time: 16:00 [CST]
Last Update Date: 11/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES CREED (R3)
WAYNE HODGES (NMSS)
FRANK CONGEL (IRO)
Event Text
AGREEMENT STATE REPORT INVOLVING INDIVIDUAL RECEIVING > 5X ANNUAL LIMIT ON INTAKE (ALI) OF TRITIUM (INHALATION)

AT 1645 HOURS ON 11/2/99, THE ILLINOIS DEPARTMENT OF NUCLEAR SAFETY WAS INFORMED THAT AN INDIVIDUAL HAD SMASHED A TUBE ON 11/1/99 CONTAINING 2 CURIES TRITIUM FROM A SELF-POWERED EXIT SIGN INSIDE HIS RESIDENTIAL GARAGE. THIS QUANTITY EXCEEDS 5X THE (ALI) OF 10CFR20 APPENDIX B (1 ALI INHALATION IS 80 mCi). THE REMAINING THREE TUBES WERE SAFELY REMOVED FROM THE INDIVIDUAL'S GARAGE. THE INDIVIDUAL INITIALLY CONTACTED A POISON HOTLINE AND WAS REFERRED. INSPECTORS FROM THE STATE AGENCY HAVE SURVEYED THE GARAGE AND ARE FOLLOWING UP.