Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for September 27, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           09/24/1999 - 09/27/1999

                              ** EVENT NUMBERS **

36220  36221  36222  36223  36224  36225  36226  36227  36228  36229  36230  36231 
36232  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36220       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK                 REGION:  1  |NOTIFICATION DATE: 09/23/1999|
|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 20:15[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        09/23/1999|
+------------------------------------------------+EVENT TIME:        20:00[EDT]|
| NRC NOTIFIED BY:  PHIL CHASE                   |LAST UPDATE DATE:  09/24/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          UNU                   |ROBERT SUMMERS       R1      |
|10 CFR SECTION:                                 |JOHN HANNON          NRR     |
|AAEC 50.72 (a) (1) (I)   EMERGENCY DECLARED     |CHARLES MILLER       IRO     |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |DAN RISHE            FEMA    |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PLANT ENTERED AN UNUSUAL EVENT - TOXIC GAS DETECTED IN UNIT 2 TURBINE        |
| ENCLOSURE                                                                    |
|                                                                              |
| An Unusual Event was declared at 2000 EDT due to readings of 65 ppm hydrogen |
| sulfide (HS) and 115 ppm carbon monoxide (CO) in the Unit 2 Turbine          |
| Enclosure.                                                                   |
|                                                                              |
| The oncoming shift reported the smell of rotten eggs when they arrived on    |
| site.  Inspection around the site determined the only place toxic gas was    |
| detectable was in the Unit 2 Turbine Enclosure.  There were no detectable    |
| levels of any toxic gas existing anywhere else around the plant.             |
| Inspections are on going around the plant.  The Unit 2 Turbine Enclosure has |
| been evacuated after an inspection for a source of the gasses.               |
|                                                                              |
| The licensee isolated the control room by manually initiating chlorine       |
| isolation as a precaution at 1922 EDT, this is an Engineered Safety Feature  |
| activation and reportable as a 4-hour notification.                          |
|                                                                              |
| The licensee notified the NRC Resident Inspector and the state/local         |
| government agencies.                                                         |
|                                                                              |
| * * * UPDATE AT 2321 EDT ON 9/23/99 BY TOM DOUGHERTY TO JOHN MacKINNON * *   |
| *                                                                            |
|                                                                              |
| The site de-escalated from the Unusual Event at 2312 EDT.  The toxic gas     |
| levels were verified to be nominal 0% in all areas inside and outside the    |
| power block.  The source of the toxic gas is still unknown and under         |
| investigation.  The licensee notified the NRC Resident Inspector and the     |
| state/local government agencies.  The R1DO (Robert Summers), NRR EO (John    |
| Hannon), IRO Manager (Charles Miller), and FEMA (Cegielski) have been        |
| informed.                                                                    |
|                                                                              |
| * * * UPDATE AT 1429 EDT ON 9/24/99 BY STAN GAMBLE TO FANGIE JONES * * *     |
|                                                                              |
| The licensee submitted a written summary of the event as a follow-up per     |
| their procedure guidance for NUREG-0654.  The source of the gas is still     |
| unknown, but the investigation continues.  The summary was sent to NRC       |
| Region 1.                                                                    |
|                                                                              |
| R1DO (Robert Summers) and NRR (Tad Marsh)                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36221       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DIABLO CANYON            REGION:  4  |NOTIFICATION DATE: 09/24/1999|
|    UNIT:  [1] [] []                 STATE:  CA |NOTIFICATION TIME: 02:13[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/23/1999|
+------------------------------------------------+EVENT TIME:        17:52[PDT]|
| NRC NOTIFIED BY:  STEVE WILSON                 |LAST UPDATE DATE:  09/24/1999|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOSEPH TAPIA         R4      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Hot Standby      |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| A TRANSFER IN OFFSITE POWER SOURCES CAUSED THE TURBINE DRIVEN AUXILIARY      |
| FEEDWATER PUMP TO AUTOMATICALLY START AND DISCHARGE WATER INTO THE STEAM     |
| GENERATORS.                                                                  |
|                                                                              |
| During restoration of relaying in the 500 kV switchyard an actuation caused  |
| the opening of the PCB breakers (Main Generator Breakers) supplying Unit 1   |
| from Auxiliary Power System).  Unit 1 power automatically transferred to the |
| Start-Up  power supply. The momentary loss of power during the transfer      |
| caused the Turbine Driven Auxiliary Feedwater Pump to start from an ESF      |
| actuation signal (12 kV Buses) and discharge into the Main Steam Generators. |
|                                                                              |
|                                                                              |
| Reactor Coolant Temperature decreased approximately 7 degrees F due to the   |
| operation of the Turbine Driven Auxiliary Feedwater Pump (Tave no load is    |
| 547 degrees F).  The Turbine Driven Auxiliary Feedwater pump operated for    |
| approximately 18 minutes before it was secured.  A Reactor Operator          |
| immediately closed the Turbine Driven Auxiliary Feedwater discharge valve(s) |
| to secure auxiliary feedwater to the Steam Generators, so there was very     |
| little discharge of auxiliary feedwater into the Steam Generators.  Reactor  |
| Coolant System cooldown was mainly due to the Turbine Driven Auxiliary       |
| Feedwater Turbine using the steam from the Steam Generators for its motive   |
| force.                                                                       |
|                                                                              |
| The NRC Resident Inspector will be informed of this event by the licensee.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   36222       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  HINES VA HOSPITAL                    |NOTIFICATION DATE: 09/24/1999|
|LICENSEE:  HINES VA HOSPITAL                    |NOTIFICATION TIME: 11:16[EDT]|
|    CITY:  MAYWOOD                  REGION:  3  |EVENT DATE:        09/23/1999|
|  COUNTY:                            STATE:  IL |EVENT TIME:        12:36[CDT]|
|LICENSE#:  12-01087-07           AGREEMENT:  Y  |LAST UPDATE DATE:  09/24/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |ROGER LANKSBURY      R3      |
|                                                |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  L CASE                       |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|LADM 35.33(a)            MED MISADMINISTRATION  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PATIENT'S ESOPHAGUS WAS RADIATED IN 11 DIFFERENT POSITIONS BUT IT WAS LATER  |
| DISCOVERED THAT THE AFTERLOADER WAS INITIALLY OFF BY 60 MILLIMETER AT THE    |
| START OF THE TREATMENT.                                                      |
|                                                                              |
|                                                                              |
| A patient was placed in the wrong site for radioactive treatment of his      |
| esophagus using a GammaMedIIi (afterloader). The patient's site was          |
| initially off by 60 millimeters when the afterloader started treatment of 11 |
| positions of  the patients esophagus.  The patient received 5 grays to 11    |
| positions in his esophagus but each one of the doses was off from the        |
| correct area to be irradiated by 60 millimeters.  The patient's physician    |
| was notified and the patient will be informed in writing within 15 days of   |
| the error.  The caller stated that the patient was not harmed by being       |
| irradiated in the incorrect areas of his esophagus.  The patient is          |
| scheduled for a second treatment  and during his next treatment the correct  |
| areas will be irradiated for a total dose of 5 grays times 2 fractions to 11 |
| the positions that were not treated in the first treatment because of the 60 |
| millimeter error.  The GammaMedIIi contains a 10 curie iridium-192 source.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36223       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM                    REGION:  1  |NOTIFICATION DATE: 09/24/1999|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 11:39[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/24/1999|
+------------------------------------------------+EVENT TIME:        07:54[EDT]|
| NRC NOTIFIED BY:  MIKE GWIRTZ                  |LAST UPDATE DATE:  09/24/1999|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROBERT SUMMERS       R1      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CONTAINMENT GASEOUS ACTIVITY MONITOR ALARM DURING DETENSIONING OF THE        |
| REACTOR VESSEL HEAD IN PREPARATION FOR A HEAD LIFT                           |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "At 0754, with normal maintenance activities in progress, the 1R12A, [which  |
| is] the containment gaseous activity monitor, went into alarm.  The alarm    |
| setpoint is two times background per technical specifications, and [it] is   |
| set at 135 counts per minute.  The containment purge and  pressure relief    |
| valves were already closed, so no actuations occurred, although this was a   |
| valid signal.  Other containment area monitors showed no rise in activity    |
| levels other than one [local] area monitor on [the] 78 elevation which       |
| showed a slight increase.  No release [is in] progress.  We will continue to |
| monitor levels and investigate the source of the increase."                  |
|                                                                              |
| The licensee stated that the normal maintenance activities in progress at    |
| the time of the alarm involved detensioning of the reactor vessel head in    |
| preparation for a head lift.  The unit is not currently in a technical       |
| specification limiting condition for operation as a result of this event due |
| to the current mode of operation (Refueling).                                |
|                                                                              |
| The licensee plans to notify the NRC resident inspector and the Lower        |
| Alloways Creek Township.                                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36224       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 09/24/1999|
|LICENSEE:  RONE ENGINEERS                       |NOTIFICATION TIME: 11:52[EDT]|
|    CITY:  DALLAS                   REGION:  4  |EVENT DATE:        09/23/1999|
|  COUNTY:                            STATE:  TX |EVENT TIME:        11:00[CDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  09/24/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOSEPH TAPIA         R4      |
|                                                |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES OGDEN                  |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN TROXLER GAUGE                                |
|                                                                              |
| "Another stolen Troxler Gauge Model 3401, Serial Number 9934, with two       |
| sources:  1) 7.8 mCi Cs-137, Serial Number 40-7404 and 2) 40 mCi AmBe-241,   |
| Serial Number 46-1316.                                                       |
|                                                                              |
| "Stolen Dallas, Texas, 09/23/99 at approximately 11:00 a.m. from Rone        |
| Engineers, 11234 Goodnight Lane, Dallas, Texas 75229, (817) 831-6211.        |
| Stolen from company pickup truck.  Lock cut and chain and device removed     |
| from truck while driver/operator at lunch.                                   |
|                                                                              |
| "Note:  This is the 7th gauge stolen/missing in the Dallas/North Texas area  |
| since March 1999.  Two more in the Houston area since October 1998.  Posting |
| notice to all Texas Licensees using MD gauges on BRC Website and in our      |
| Radiation Report (Winter Edition) concerning increased security needs for    |
| users of gauges."                                                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36225       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WESTVACO BLEACHBOARD DIVISION        |NOTIFICATION DATE: 09/24/1999|
|LICENSEE:  OHMART                               |NOTIFICATION TIME: 15:39[EDT]|
|    CITY:  COVINGTON                REGION:  2  |EVENT DATE:        09/23/1999|
|  COUNTY:                            STATE:  VA |EVENT TIME:        11:00[EDT]|
|LICENSE#:  45-01568-01           AGREEMENT:  N  |LAST UPDATE DATE:  09/24/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |THOMAS DECKER        R2      |
|                                                |KEVIN RAMSEY (FAX)   NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  RAYMOND HUNDLEY              |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 10 CFR PART 21 REPORT - FAILURE, SOURCE SHUTTER STUCK OPEN                   |
|                                                                              |
| During the performance of the six month surveillances of sources, one        |
| source's shutter was discovered to be stuck open.  The device is an Ohmart   |
| SH-F2-0, serial number 4612GK, with a sealed source of 1000 mCi of Cs-137.   |
| There is no indication of what the problem might be, no rust or apparent     |
| damage.  The shutter mechanism could not be moved manually.                  |
|                                                                              |
| The manufacturer was contacted and they directed the licensee to lubricate   |
| the shutter and if that did not free up the shutter mechanism, they would    |
| send representatives to the site.                                            |
|                                                                              |
| The device is used on the manufacturing line, it is a fixed installation.    |
| There is little or no safety implications to personnel as installed.         |
|                                                                              |
| * * * UPDATE AT 1626 EDT ON 9/24/99 BY RAYMOND HUNDLEY TO FANGIE JONES * *   |
| *                                                                            |
|                                                                              |
| The shutter mechanism was treated with lubricating oil and it was freed.     |
| The device is working properly.  A written report will follow within 30      |
| days.                                                                        |
|                                                                              |
| R2DO (Thomas Decker) and NMSS (Kevin Ramsey) have been contacted.            |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36226       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 09/24/1999|
|    UNIT:  [1] [2] []                STATE:  IL |NOTIFICATION TIME: 15:40[EDT]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        09/24/1999|
+------------------------------------------------+EVENT TIME:        14:00[CDT]|
| NRC NOTIFIED BY:  PAUL SALGADO                 |LAST UPDATE DATE:  09/25/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROGER LANKSBURY      R3      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       99       Power Operation  |99       Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| VENTILATION DAMPER FOUND TO FAIL OPEN INSTEAD OF CLOSED                      |
|                                                                              |
| "During an engineering review of an industry event it was determined that a  |
| design flaw of a ventilation damper that feeds the Aux electric equipment    |
| room fails open instead of failing closed.  With this valve failing open it  |
| introduces 15000 CFM of air to the AEER and causes it to become positive in  |
| pressure with respect to the control room emergency  zone.  This allows a    |
| leak path into the control room and can affect the dose to the control room  |
| operators.  Compensatory measures are being planned that will gag closed     |
| this damper to rectify the problem."                                         |
|                                                                              |
| The gagging of the damper is the temporary fix, a long term fix is being     |
| investigated.                                                                |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| * * * RETRACTED AT 1927 EDT ON 9/25/99 BY BRIAN SAMPSON TO FANGIE JONES * *  |
| *                                                                            |
|                                                                              |
| Upon further review of the damper operation by Dresden Operations and        |
| Engineering personnel, it was determined that the damper in question will    |
| fail closed, which is the desired position for post-accident conditions.     |
| Therefore the condition is not outside design basis, and is not reportable.  |
| This event report is retracted.                                              |
|                                                                              |
| The licensee notified the NRC Resident Inspector.  The R3DO (Roger           |
| Lanksbury) has been notified.                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   36227       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 09/24/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 17:15[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        09/24/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        13:30[EDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  09/24/1999|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |ROGER LANKSBURY      R3      |
|  DOCKET:  0707002                              |JOHN SURMEIER        NMSS    |
+------------------------------------------------+CHARLES MILLER       IRO     |
| NRC NOTIFIED BY:  RICK LARSON                  |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 4 HOUR NRC 91-01 BULLETIN REPORT                                             |
|                                                                              |
| "ON 9/24/99 AT 1330 AN ANALYSIS OF A TACKY TEXTURED SUBSTANCE FOUND IN THE   |
| SIDE PURGE PIPING DURING REPAIRS TO THIS SYSTEM REVEALS A URANIUM COMPOUND   |
| THAT IS UNPRECEDENTED IN CASCADE OPERATIONS.  THE COMPOUND UO2CL(OH).2H2O    |
| HAS A H/U RATIO OF 5.  THE ASSUMED PROCESS MODERATION CONDITION FOR          |
| NCSA-PLANT 062.AO2 HAS BEEN EXCEEDED, RESULTING IN A LOSS OF ONE LEG OF      |
| DOUBLE CONTINGENCY.  THE OTHER LEG OF DOUBLE CONTINGENCY (MASS CONTROL) HAS  |
| BEEN MAINTAINED.                                                             |
|                                                                              |
| "THIS IS REPORTABLE PER NRC BL 91-01 FOR 'OCCURRENCE OF ANY UNANTICIPATED OR |
| UNANALYZED EVENT FOR WHICH  THE CORRECTIVE ACTIONS TO RE-ESTABLISH DOUBLE    |
| CONTINGENCY ARE NOT READILY IDENTIFIABLE..                                   |
|                                                                              |
|                                                                              |
| "SAFETY SIGNIFICANCE OF EVENTS:                                              |
|                                                                              |
| "THE PRESENCE OF UO2CL(0H).2H2O (H/U = 5) RESULTS IN THE LOSS OF MODERATION  |
| CONTROL IN THE SECTION OF THE SIDE PURGE PIPING WHERE THE COMPOUND IS        |
| PRESENT (i.e., THE ASSUMED NORMAL MODERATION PROCESS CONDITION WAS           |
| EXCEEDED.) THE PREDOMINANT ENRICHMENT OF URANIUM-BEARING MATERIAL INSIDE THE |
| PIPE IS APPROXIMATELY 6%.  HOWEVER, THERE ARE NO GREATER THAN SAFE MASS      |
| DEPOSITS IN THE AREA NEAR THIS MATERIAL, NOR IS THERE A POTENTIAL FOR        |
| DEPOSIT MOVEMENT (e.g., VIA FLAKING) WHICH COULD CREATE A GREATER THAN SAFE  |
| MASS DEPOSIT.  THEREFORE, MASS CONTROL IS STILL MAINTAINED, AND A            |
| CRITICALITY CANNOT OCCUR WITHOUT THE ADDITION OF MORE URANIUM MASS.  THIS IS |
| HIGHLY UNLIKELY IF NOT INCREDIBLE BECAUSE THE SIDE PURGE CASCADE PIPING IS   |
| CURRENTLY ISOLATED FROM THE OPERATING CASCADE, AND IS AT A HIGHER PRESSURE   |
| THAN THE SURROUNDING OPERATING EQUIPMENT.  THE FORMATION OF THIS COMPOUND    |
| WAS ONLY POSSIBLE BECAUSE OF THE CONDITIONS PRESENT DURING THE X-326 FIRE;   |
| THEREFORE, OTHER CASCADE EQUIPMENT IS NOT IMPACTED BY THE PRESENCE OF THIS   |
| COMPOUND.  BASED ON THIS. IT IS CONCLUDED THAT THE SAFETY SIGNIFICANCE OF    |
| THIS EVENT IS LOW.                                                           |
|                                                                              |
| "POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO[S] OF HOW           |
| CRITICALITY COULD OCCUR);                                                    |
|                                                                              |
| "THE ONLY WAY THAT A CRITICALITY COULD OCCUR IS IF ADDITIONAL URANIUM MASS   |
| IS ADDED TO THE SIDE PURGE PIPE, CREATING A GREATER THAN SAFE MASS DEPOSIT.  |
| AS DISCUSSED ABOVE, THIS IS HIGHLY UNLIKELY IF NOT INCREDIBLE BECAUSE THE    |
| SIDE PURGE.  CASCADE PIPING IS CURRENTLY ISOLATED FROM THE OPERATING         |
| CASCADE, AND IS AT A HIGHER PRESSURE THAN THE SURROUNDING OPERATING          |
| EQUIPMENT.  THEREFORE, A VALVING ERROR WOULD HAVE TO OCCUR AT THE SAME TIME  |
| AS A MAJOR CASCADE UPSET CAUSING INCREASED PRESSURES IN THE SURROUNDING      |
| OPERATING CASCADE EQUIPMENT.  IN ORDER FOR THE MORE MASS TO ENTER THIS       |
| PIPE.                                                                        |
|                                                                              |
| "CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, ETC.):    |
|                                                                              |
| "MASS MAINTAINED,  MODERATION-LOST                                           |
|                                                                              |
| "ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS    |
| LIMIT AND % WORST CASE OF CRITICAL MASS):                                    |
|                                                                              |
| "THE PREDOMINANT ENRICHMENT OF THE MATERIAL IN THE PIPE IS APPROXIMATELY 6%. |
| THE COMPOUND OF CONCERN IS IN THE FORM OF UO2CL(OH).2H2O (H/U=5).  THE MASS  |
| OF THE LARGEST DEPOSIT IN THE AREA IS APPROXIMATELY 159 GRAMS 235U, WHICH IS |
| WELL BELOW A SAFE MASS OF 740 GRAMS 235U.  THE SAFE MASS ASSUMES 6%          |
| ENRICHMENT OPTIMUM SPHERICAL GEOMETRY OPTIMUM MODERATION, AND FULL           |
| REFLECTION, AND INCLUDES A SAFETY MARGIN OF APPROXIMATELY A FACTOR OF 2 FROM |
| THE ACTUAL CRITICAL MASS.                                                    |
|                                                                              |
| "NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION  |
| OF THE FAILURES OR DEFICIENCIES:                                             |
|                                                                              |
| "THE NCSA PROVIDES CONTROLS ON MASS AND MODERATION.  THE PRESENCE OF         |
| UO2CL(OH).2H2O (H/U=5) RESULTS TS IN A LOSS OF CONTROL OF THE PROCESS        |
| CONDITION.  MASS CONTROLS WERE MAINTAINED.                                   |
|                                                                              |
| "CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS IMPLEMENTED:  |
|                                                                              |
| "THE FOLLOWING CORRECTIONS ACTIONS ARE BEING TAKEN:  AREA WILL REMAIN        |
| BOUNDARIED, NCSA-PLANT 062 MAINTENANCE ACTIVITIES WILL REMAIN SUSPENDED, AND |
| NCS WILL DEVELOP AN NCSA TO COVER THIS OPERATION."                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36228       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WASHINGTON DEPARTMENT OF HEALTH      |NOTIFICATION DATE: 09/24/1999|
|LICENSEE:  WHEELABRATOR                         |NOTIFICATION TIME: 18:55[EDT]|
|    CITY:  SPOKANE                  REGION:  4  |EVENT DATE:        09/09/1999|
|  COUNTY:                            STATE:  WA |EVENT TIME:             [PDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  09/24/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LAWRENCE YANDELL     R4      |
|                                                |JOHN SURMEIER        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  TERRY FRAZEE                 |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| WASTE-TO-ENERGY FACILITY HAD RADIATION ALARM ON INCOMING LOAD                |
|                                                                              |
| Agreement State Event Report #WA-99-025                                      |
|                                                                              |
| The following text is a portion of E-mail received from the Washington       |
| Department of Health, Division of Radiation Protection:                      |
|                                                                              |
| "A waste-to-energy facility in Spokane reported a radiation alarm on an      |
| incoming load of residential waste.  The facility separated the load,        |
| finding a plastic bag with "kitty litter" reading about 8 mR/hr on contact.  |
| They notified DOH and isolated the material in their locked storage area. On |
| September 15, 1999, DOH staff identified the offending radionuclide to be    |
| I-131 and confirmed that the contents appeared to be cat litter.  There was  |
| no accompanying waste that could identify the origin of the waste.  It is    |
| presumed that a local cat was receiving                                      |
| treatment for a thyroid condition and had been released to its owner with a  |
| small amount of residual radioactivity (only a few microcuries were present  |
| in the litter).   The material is being held for decay.                      |
|                                                                              |
| "Activity and Isotope(s) involved: An unknown (but small) amount of I-131"   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   36229       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WASHINGTON DEPARTMENT OF HEALTH      |NOTIFICATION DATE: 09/24/1999|
|LICENSEE:  UNIVERSITY OF WASHINGTON HOSPITAL    |NOTIFICATION TIME: 19:02[EDT]|
|    CITY:  SEATTLE                  REGION:  4  |EVENT DATE:        09/17/1999|
|  COUNTY:                            STATE:  WA |EVENT TIME:             [PDT]|
|LICENSE#:  WN-C001-1             AGREEMENT:  Y  |LAST UPDATE DATE:  09/24/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LAWRENCE YANDELL     R4      |
|                                                |JOHN SURMEIER        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  ROBERT VERELLEN              |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THREE I-125 BRACHYTHERAPY SOURCES LOST                                       |
|                                                                              |
| Agreement State Event Report #WA-99-027                                      |
|                                                                              |
| The following text is a portion of E-mail received from the Washington       |
| Department of Health, Division of Radiation Protection:                      |
|                                                                              |
| "THE LICENSEE REPORTED THE LOSS OF THREE I-125 BRACHY SOURCES, AMERSHAM      |
| MODEL 6720, 0.529 MICROCURIE EACH [1.587 MICROCURIES TOTAL].  THE SOURCES    |
| COME FROM THE MANUFACTURER IN A SET OF TEN SEEDS (SOURCES) IN A DICYL        |
| SUTURE.  FOR THE APPROPRIATE NUMBER OF SEEDS TO MEET THE INDIVIDUALIZED      |
| TREATMENT PLAN IT IS COMMON FOR THE SUTURE TO BE TRIMMED.  IN THIS CASE      |
| THREE SEEDS WERE TRIMMED BUT WERE UNACCOUNTED FOR DURING A SOURCE COUNT      |
| PERFORMED ON THE 17 SEPT. 1999.  UPON DISCOVERY OF THE MISSING SOURCES THE   |
| LICENSEE HAS PERFORMED SURVEY OF ALL POSSIBLE AREAS WITHIN THE HOSPITAL BUT  |
| DID NOT FIND THEM.  THEY REPORT THAT THE SOURCES WERE PROBABLY  LOST, MIXED  |
| WITH SOME OF THE OPERATING ROOM MATERIALS, WHICH HAD BEEN AUTOCLAVED AND     |
| DISPOSED OF IN A DUMPSTER WHICH HAD BEEN PICKED UP BEFORE THEY WERE AWARE OF |
| THE MISSING SOURCES.  AN INVESTIGATION IS ONGOING MORE DETAILS WILL BE       |
| FORTHCOMING."                                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36230       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAN ONOFRE               REGION:  4  |NOTIFICATION DATE: 09/25/1999|
|    UNIT:  [1] [2] []                STATE:  CA |NOTIFICATION TIME: 12:41[EDT]|
|   RXTYPE: [1] W-3-LP,[2] CE,[3] CE             |EVENT DATE:        09/24/1999|
+------------------------------------------------+EVENT TIME:        20:10[PDT]|
| NRC NOTIFIED BY:  CLAY WILLIAMS                |LAST UPDATE DATE:  09/25/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LAWRENCE YANDELL     R4      |
|10 CFR SECTION:                                 |                             |
|NLTR                     LICENSEE 24 HR REPORT  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
|  24 HOUR REPORT UNDER CONDITION OF LICENSE REGARDING FOR UNUSUAL FISH KILL   |
|                                                                              |
| A periodic heat treatment, the temperature of the intake structure is raised |
| in order to limit biological fouling.  After the heat treatment a fish kill  |
| was discovered.  The total weight, 4800 pounds, is greater than the          |
| reporting limit of 4500 pounds.                                              |
|                                                                              |
| The licensee notified the NRC Resident Inspection.                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36231       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM                    REGION:  1  |NOTIFICATION DATE: 09/26/1999|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 00:52[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/25/1999|
+------------------------------------------------+EVENT TIME:        23:30[EDT]|
| NRC NOTIFIED BY:  S. SAUER                     |LAST UPDATE DATE:  09/26/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROBERT SUMMERS       R1      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CONTAINMENT VENTILATION ISOLATION                                            |
|                                                                              |
| An automatic containment ventilation isolation (CVI) was initiated by the    |
| containment air particulate monitor (1R11A). The containment purge system    |
| was in service at the time, and the system isolated as designed. The         |
| licensee is currently evaluating the cause of this isolation, and is         |
| obtaining and analyzing grab samples to determine whether an increase in     |
| particulate activity may have occurred.                                      |
|                                                                              |
| The NRC resident inspector will be informed of this event by the licensee.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36232       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: VOGTLE                   REGION:  2  |NOTIFICATION DATE: 09/26/1999|
|    UNIT:  [] [2] []                 STATE:  GA |NOTIFICATION TIME: 06:45[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/26/1999|
+------------------------------------------------+EVENT TIME:        03:30[EDT]|
| NRC NOTIFIED BY:  CHARLIE MEYER                |LAST UPDATE DATE:  09/26/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |THOMAS DECKER        R2      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       93       Power Operation  |93       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOTH TRAINS OF THE SAFETY INJECTION SYSTEM DECLARED INOPERABLE               |
|                                                                              |
| Both trains of the safety injection (SI) system were declared inoperable due |
| to the discovery of excessive volumes of air from both SI pump casings. The  |
| air was discovered during performance of the monthly ECCS flow path          |
| verification surveillance procedure. Both pumps were subsequently vented and |
| declared operable at 0610 9/26/1999. The licensee is investigating the cause |
| of the entrapped air.                                                        |
|                                                                              |
| The NRC resident inspector has been informed of this event by the licensee.  |
+------------------------------------------------------------------------------+