Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for September 16, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           09/15/1999 - 09/16/1999

                              ** EVENT NUMBERS **

36149  36156  36163  36164  36165  36166  36167  36168  36169  36170  36171  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36149       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NORTH ANNA               REGION:  2  |NOTIFICATION DATE: 09/12/1999|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 09:30[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        09/12/1999|
+------------------------------------------------+EVENT TIME:        09:04[EDT]|
| NRC NOTIFIED BY:  VICKY HARTE                  |LAST UPDATE DATE:  09/15/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |                             |
|AENS 50.72(b)(1)(v)      ENS INOPERABLE         |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       60       Power Operation  |60       Power Operation  |
|2     N          N       0        Hot Standby      |0        Hot Standby      |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOST SAFETY PARAMETER DISPLAY SYSTEM AND THE TECHNICAL SUPPORT CENTER        |
| COMPUTER                                                                     |
|                                                                              |
| Power was lost  to the Safety Parameter Display System (SPDS) and the        |
| Technical Support Center (TSC) computer system at 0904 EDT on 9/12/99.  The  |
| bus supplying power to the battery charger for the SPDS and TSC computer was |
| lost when the supply breaker opened on a ground detection, on the            |
| underground cable supply.  The normal alternate power supply to the battery  |
| charger was previously lost, some time ago, due to another ground on its     |
| underground cable supply.  The licensee made the decision to preserve the    |
| battery and deenergized the battery bus.  Also, with the TSC computer system |
| out-of-service, the control room will serve as the alternate TSC facility.   |
|                                                                              |
| This event is a major loss of emergency  assessment capability and is        |
| reportable.  Troubleshooting and repairs to the electrical distribution      |
| system are in progress.  Also, the licensee is investigating an alternate    |
| methods to power the battery charger.                                        |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
|                                                                              |
| ***Update on 09/15/99 at 1255ET by Kemp taken by MacKinnon***                |
|                                                                              |
| Power was restored to the TSC and the SPDS was restored to service at 1132ET |
| today (09/15/99).  R2DO (Chris Christensen) notified.                        |
|                                                                              |
| The NRC Resident Inspector will be informed by the licensee of this update.  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36156       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 09/13/1999|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 17:30[EDT]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        09/13/1999|
+------------------------------------------------+EVENT TIME:        17:13[EDT]|
| NRC NOTIFIED BY:  STEVE MERRILL                |LAST UPDATE DATE:  09/15/1999|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          UNU                   |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |JOSEPH GIITTER       IRO     |
|AAEC 50.72 (a) (1) (I)   EMERGENCY DECLARED     |DAN SULLIVAN         FEMA    |
|                                                |FRANK CONGEL         IRO     |
|                                                |ELINOR ADENSAM       NRR     |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Hot Shutdown     |0        Hot Shutdown     |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO ENTERING EAL 5B ITEM 1 (CONFIRMED HURRICANE    |
| WARNING IN EFFECT)                                                           |
|                                                                              |
| The licensee entered an Unusual Event per Emergency Action Level 5B item 1.  |
| All emergency diesel generators are fully operable and the electrical grid   |
| is stable.  All emergency core cooling systems are fully operable. The state |
| was notified of the Unusual Event classification.  Local counties will be    |
| notified of the Unusual Event classification by the state of Florida.        |
|                                                                              |
| The NRC Resident Inspector will be notified of this event by the licensee.   |
|                                                                              |
| * * * UPDATE 0930 9/14/1999 BY STRANSKY * * *                                |
|                                                                              |
| The NRC entered the Monitoring Phase of Normal Mode at 0930 on 9/14/1999 in  |
| preparation of potential landfall by Hurricane Floyd.                        |
|                                                                              |
| * * * COMMISSIONER'S ASSISTANTS BRIEF, 1000 EDT ON 9/14/99 * * *             |
|                                                                              |
| Luis Reyes the R2RA conducted the brief, IRO (Frank Congel), NRR (Tad        |
| Marsh), NMSS (Josie Piccone), PA (William Beecher), SP (Fred Combs), R2 IRC  |
| (Pierce Skinner), CA (Betsy Keeling), EDO Staff (Leonard Wert), IP (Karen    |
| Henderson), SECY (Andrew Bates), Chairman Dicus Off (Thomas Hiltz), Comm.    |
| McGaffigan Off (James Beall), Comm. Diaz Off (Anthony Hsia), Comm.           |
| Merrifield Off (Lynne Stauss)                                                |
|                                                                              |
| *** COMMISSIONER'S ASSISTANCE BRIEF, 2000 EDT ON 9/14/99 ***                 |
|                                                                              |
| Luis Reyes the R2RA conducted the brief, EDO (Jim Dyer), IRO ( Joe Giitter), |
| NRR EO (Bill Beckner), NMSS (Josie Piccone), CA (Betsy Keeling), Chairman    |
| Dicus Off (Tom Hiltz), Comm McGaffigan (James Beall),  Comm Merrifield       |
| (Lynne Stauss & John Thoma), NRC R2 (Bruce Mallett & Anne Boland) .          |
|                                                                              |
| * * * UPDATE AT 0059 EDT ON 9/15/99 BY JACK BREEN TO FANGIE JONES * * *      |
|                                                                              |
| Unusual Event was terminated at 0040 EDT when the hurricane warning was      |
| lifted by the National Hurricane Center.  The licensee notified the NRC      |
| Resident Inspector and intends notifying the state and surrounding counties  |
| of exiting the Unusual Event.  R2DO (Chris Christensen), NRR EO (William     |
| Beckner), and FEMA (Wayne Storer) notified.                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36163       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK                REGION:  2  |NOTIFICATION DATE: 09/14/1999|
|    UNIT:  [1] [2] []                STATE:  NC |NOTIFICATION TIME: 23:30[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        09/14/1999|
+------------------------------------------------+EVENT TIME:        23:10[EDT]|
| NRC NOTIFIED BY:  THOMAS WOODALL               |LAST UPDATE DATE:  09/16/1999|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          UNU                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |WILLIAM BECKNER      NRR     |
|AAEC 50.72 (a) (1) (I)   EMERGENCY DECLARED     |FRANK CONGEL         IRO     |
|                                                |WAYNE STORER         FEMA    |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO ENTERING EAL 2.1 SECTION 14.1.2 (NATURAL EVENT |
| - HURRICANE WARNING).                                                        |
|                                                                              |
| The licensee entered an Unusual Event per Emergency Action Level 2.1 Section |
| 14.1.2.  All emergency diesel generators and their emergency core cooling    |
| systems are fully operable. The electrical grid is stable. The licensee said |
| that they would have to enter Abnormal Operating Procedure 13 two hours      |
| before wind speed increased to 75 mph.  The licensee projects that they have |
| 27 hours until hurricane force winds reach their site.                       |
| The licensee has notified the state of North Carolina and surrounding        |
| counties of entering an unusual event classification.                        |
|                                                                              |
| The NRC Resident Inspector will be informed of this event by the licensee.   |
|                                                                              |
| * * * UPDATE 0845EDT ON 9/15/99 FROM DON DEWEY TO S. SANDIN * * *            |
|                                                                              |
| The licensee decided at 0830EDT to reduce power on both units to 40% by      |
| 1000EDT and hold.  A decision as to whether a shutdown should continue will  |
| be made at that time.  Unit 1 and 2 are currently at 76% and 82% power,      |
| respectively.  The licensee will inform the NRC Resident Inspector.          |
| Notified R2 IRC(Skinner).                                                    |
|                                                                              |
|                                                                              |
| ***UPDATE AT 1248ET ON 09/15/99 BY DON DEWEY TAKEN BY MACKINNON***           |
|                                                                              |
| Brunswick Unit 2 was manually scrammed from 31% reactor power at 1118 hours. |
| All systems operated as expected.                                            |
|                                                                              |
| Brunswick Unit 1 was manually scrammed from 35% reactor power at 1206 hours. |
| All systems operated as expected.                                            |
|                                                                              |
| All Emergency Core Cooling Systems and the Emergency Diesel Generators are   |
| fully operable if needed. The offsite electrical grid at this time is        |
| stable.  On site wind speed is 32 mph.                                       |
|                                                                              |
| R2DO (Chris Christensen &  Pierce Skinner), NRR (Bill Beckner & Bob Dennig)  |
| and IRO (Joe Giitter)  notified.                                             |
|                                                                              |
| The NRC Resident Inspector was notified of this event update by the          |
| licensee.                                                                    |
|                                                                              |
| ***UPDATE AT 2016ET ON 09/15/99 BY ROBBINS TAKEN BY MACKINNON***             |
|                                                                              |
| Brunswick Unit 2 entered a cold shutdown condition at 1935 hours and         |
| Brunswick Unit 2 entered a cold shutdown condition at 1955 hours.  Onsite    |
| wind speed is 34 mph.  R2DO (Chris Christensen) & NRC Region 2 IRC (Anne     |
| Boland) notified.                                                            |
|                                                                              |
| The NRC Resident Inspector was notified of this update by the licensee.      |
|                                                                              |
| * * * UPDATE 0510EDT ON 9/16/99 VIA FAX TO S. SANDIN * * *                   |
|                                                                              |
| Message #6  was received via fax:                                            |
|                                                                              |
| "32 of the 35 Emergency Warning Sirens are now indicating an inoperable      |
| status due to a loss of power.  Some siding panels from the turbine building |
| have been lost.  The turbine building radiological conditions are monitored. |
| Both Units are in cold shutdown." [see event #36169]  Meteorological         |
| conditions as of 0458EDT were wind direction from 240-280 degrees, speed     |
| 75-95 mph, stability class D with rain.  Notified R2 IRC(Reyes).             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36164       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK                REGION:  2  |NOTIFICATION DATE: 09/15/1999|
|    UNIT:  [1] [2] []                STATE:  NC |NOTIFICATION TIME: 11:31[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        09/15/1999|
+------------------------------------------------+EVENT TIME:        09:35[EDT]|
| NRC NOTIFIED BY:  DAVID JENKINS                |LAST UPDATE DATE:  09/15/1999|
|  HQ OPS OFFICER:  WILLIAM POERTNER             +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       60       Power Operation  |60       Power Operation  |
|2     N          Y       60       Power Operation  |60       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO OPENING STORM DRAIN BYPASS VALVES                |
|                                                                              |
| On September 15, 1999, at 0935 EDT, the bypass valves from the site's storm  |
| drain basin directly to the circulating water discharge canal were opened to |
| prevent site flooding (which could cause significant damage to plant         |
| equipment and/or possibly endanger personnel safety) due to the impending    |
| arrival of hurricane Floyd.  Past experience has shown that the installed    |
| pump capacity will not keep up with the rain expected during a hurricane.    |
| The valves were opened prior to hurricane force winds reaching the site to   |
| avoid exposing personnel to the hurricane.   Opening these valves is a       |
| reportable event (to the state of North Carolina) in accordance with the     |
| site National Pollutant Discharge Elimination System permit.                 |
|                                                                              |
| The NRC resident has been notified.                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   36165       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WILLIAM BEAUMONT HOSPITAL            |NOTIFICATION DATE: 09/15/1999|
|LICENSEE:  WILLIAM BEAUMONT HOSPITAL            |NOTIFICATION TIME: 14:59[EDT]|
|    CITY:  ROYAL OAK                REGION:  3  |EVENT DATE:        09/15/1999|
|  COUNTY:                            STATE:  MI |EVENT TIME:        11:00[EDT]|
|LICENSE#:  21-01333-01           AGREEMENT:  N  |LAST UPDATE DATE:  09/15/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |GARY SHEAR           R3      |
|                                                |JOSIE PICCONE        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHERYL SCHULTZ               |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|LADM 35.33(a)            MED MISADMINISTRATION  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PATIENT RECEIVED A PLACEBO INSTEAD OF 20 GRAY OF P-32.                       |
|                                                                              |
| A patient signed a consent form to participate in a coronary brachytherapy   |
| trial to evaluate the Guidant Coronary Afterloader.  The patient was         |
| randomized to receive 20 Gray to the proximal left anterior descending       |
| coronary artery with P-32, but the Radiation Oncology physicist programmed   |
| the afterloader to use the placebo source wire instead.  Therefore, the      |
| patient did not receive the prescribed dose of 20 Gray.  The root cause for  |
| the error was that the Radiation Oncologist did not adequately confirm the   |
| written directive prior to treatment.  There was no documentation on the     |
| randomization order to guide the physicist in selecting the proper           |
| treatment, so he relied on his memory, which failed.                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36166       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 09/15/1999|
|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 16:06[EDT]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        09/15/1999|
+------------------------------------------------+EVENT TIME:        15:36[EDT]|
| NRC NOTIFIED BY:  PHIL SANTINI                 |LAST UPDATE DATE:  09/15/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |NIEL DELLA GRECA     R1      |
|10 CFR SECTION:                                 |                             |
|AEXT 50.72(b)(1)(iii)    EXTERNAL THREAT        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          N       0        Hot Shutdown     |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HURRICANE WINDS PREDICTED TO COME WITHIN 500 NM OF SITE                      |
|                                                                              |
| At 1536, the licensee was notified that the National Weather Service had     |
| issued hurricane warnings for North Carolina and Virginia, with hurricane    |
| force winds extending 140 miles outward from the center of Hurricane Floyd.  |
| The licensee considers that the arrival of hurricane force winds within 500  |
| nautical miles (NM) of Indian Point, concurrent with hurricane warnings is   |
| imminent. This notification is being made in accordance with Technical       |
| Specification 3.14.a and Abnormal Operating Instruction 28.07. The NRC       |
| resident inspector will be informed of this notification by the licensee.    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36167       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY                    REGION:  2  |NOTIFICATION DATE: 09/15/1999|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 22:17[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        09/15/1999|
+------------------------------------------------+EVENT TIME:        22:00[EDT]|
| NRC NOTIFIED BY:  DON KARNS                    |LAST UPDATE DATE:  09/16/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          UNU                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |ANN BOLAND           R2      |
|AAEC 50.72 (a) (1) (I)   EMERGENCY DECLARED     |WILLIAM BECKNER      NRR     |
|                                                |FRANK CONGEL         IRO     |
|                                                |BELCHER              FEMA    |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |83       Power Operation  |
|2     N          Y       100      Power Operation  |47       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO APPROACHING HURRICANE                          |
|                                                                              |
| An Unusual Event was declared at 2200 EDT due to the expected onset of       |
| hurricane force winds within the following 12 hours. The licensee currently  |
| expects that hurricane force winds will occur onsite at 1000 EDT. Both units |
| are currently being shut down in anticipation of the hurricane arrival.      |
| Shutdown of Unit 2 commenced at 1906 EDT, and Unit 1 began shutting down at  |
| 2040 EDT. The NRC resident inspector has been informed of this               |
| notification.                                                                |
|                                                                              |
| * * * UPDATE 0210EDT ON 9/16/99 FROM DALE JONES TO S. SANDIN * * *           |
|                                                                              |
| The licensee is holding power at 46% on Unit 1 and 35% on Unit 2 pending an  |
| assessment of the path of Hurricane Floyd.  Current projections for maximum  |
| sustained wind on site indicate less than 60 mph due to the more easterly    |
| course change.  Notified R2DO(Christensen) and R2(Boland).                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36168       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 09/15/1999|
|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 22:55[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        09/15/1999|
+------------------------------------------------+EVENT TIME:        18:25[CDT]|
| NRC NOTIFIED BY:  JOSEPH BENNETT               |LAST UPDATE DATE:  09/15/1999|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     M/R        Y       52       Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR MANUALLY SCRAMMED FROM 52% REACTOR POWER DUE TO AN UNCONTROLLABLE    |
| LOSS OF ELECTROHYDRAULIC CONTROL (EHC) FLUID.                                |
|                                                                              |
|                                                                              |
| At approximately 1750 on 09/15/99, failure of an EHC system pressure sensing |
| line resulted in an uncontrollable loss of EHC fluid.  Attempts to maintain  |
| EHC reservoir level failed, and a 1825 hours, the reactor was manually       |
| scrammed from 52% reactor power in preparation for removing the EHC system   |
| from service.  Reactor power was initially at 100% and it was reduced to 52% |
| before the reactor was manually scrammed.  The scram resulted in a low       |
| reactor vessel water level, causing an automatic isolation of Primary        |
| Containment Isolation System (PCIS) groups 2 (Drywell isolations), 3         |
| (Reactor Water Cleanup trip/isolation), &8 (transversing incore probe system |
| isolation).  EOI-1  was entered due to low reactor vessel water level        |
| {decreased to negative 28.5", Top of Active Fuel (TAF) is negative 162"} and |
| to control reactor pressure with the loss of the EHC system.  No Main Steam  |
| Safety Relief Valves (MSRVs) were actuated during this event.  All control   |
| rods fully inserted into the core.                                           |
|                                                                              |
| The licensee started that restart is projected for 1600 hours on 09/16/99.   |
|                                                                              |
|                                                                              |
| NRC Region 2 Section Chief (Paul Fredrickson) was notified of this event by  |
| the licensee.                                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36169       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BRUNSWICK                REGION:  2  |NOTIFICATION DATE: 09/16/1999|
|    UNIT:  [1] [2] []                STATE:  NC |NOTIFICATION TIME: 01:21[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        09/16/1999|
+------------------------------------------------+EVENT TIME:        00:50[EDT]|
| NRC NOTIFIED BY:  DAVE JESTER                  |LAST UPDATE DATE:  09/16/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |ANNE BOLAND          R2      |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PARTIAL LOSS OF EMERGENCY SIREN CAPABILITY DURING HURRICANE FLOYD            |
|                                                                              |
| "[Operations was] informed by Brunswick Plant Emergency Preparedness         |
| personnel that 13 emergency warning offsite sirens have failed as a result   |
| of Hurricane Floyd.                                                          |
|                                                                              |
| "[The initial safety significance evaluation characterized the significance  |
| of the loss of the sirens as] minimal.   Backup alert measures are in place. |
| Local agencies have been notified.                                           |
|                                                                              |
| "[Corrective action(s) include a] complete investigation into the cause of   |
| the failure and complete required repairs."                                  |
|                                                                              |
| The thirteen [13] sirens are located primarily on the beach and on Bald Head |
| Island and Boiling Spring Lake  in Brunswick county.  There are an           |
| additional seventeen [17] operable sirens currently available in Brunswick   |
| county and five [5] more in New Hanover county.  The loss of the 13 sirens   |
| was related to loss of power as detected by an external operability check    |
| performed by a computer.  The licensee will not initiate repairs until the   |
| storm passes.                                                                |
|                                                                              |
| The licensee informed state/local agencies and the NRC Resident Inspector.   |
|                                                                              |
| * * * UPDATE 0510EDT ON 9/16/99 VIA FAX TO S. SANDIN * * *                   |
|                                                                              |
| Thirty-two [32] of the thirty-five [35] sirens are out-of-service.  See      |
| event #36163 for additional information.  Notified R2 IRC (Reyes).           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36170       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HARRIS                   REGION:  2  |NOTIFICATION DATE: 09/16/1999|
|    UNIT:  [1] [] []                 STATE:  NC |NOTIFICATION TIME: 02:32[EDT]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        09/16/1999|
+------------------------------------------------+EVENT TIME:        01:55[EDT]|
| NRC NOTIFIED BY:  KEVIN ABELL                  |LAST UPDATE DATE:  09/16/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHRIS CHRISTENSEN    R2      |
|10 CFR SECTION:                                 |ANNE BOLAND          R2      |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PARTIAL LOSS OF EMERGENCY SIREN CAPABILITY DURING HURRICANE FLOYD            |
|                                                                              |
| "The Plant was operating at 100% power when 22 Warning Sirens became         |
| inoperable due to loss of power. The counties of Chatham, Harnett, and Wake  |
| are each affected. Wind speeds in these areas are higher than normal due to  |
| the effects of hurricane Floyd. One additional Warning Siren in Wake County  |
| was previously inoperable due to failing its periodic test. Repairs will be  |
| made when wind speed subsides."                                              |
|                                                                              |
| Harris has a total of 81 sirens of which 22 represents slightly greater than |
| 25%.  Residents living within 5 miles of the site have tone alert radios as  |
| a backup.  The licensee informed the NRC resident inspector and will inform  |
| state/local agencies.                                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36171       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK                 REGION:  1  |NOTIFICATION DATE: 09/16/1999|
|    UNIT:  [] [2] []                 STATE:  PA |NOTIFICATION TIME: 04:30[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        09/16/1999|
+------------------------------------------------+EVENT TIME:        01:15[EDT]|
| NRC NOTIFIED BY:  DOUG AMTSFIELD               |LAST UPDATE DATE:  09/16/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |NIEL DELLA GRECA     R1      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - Secondary containment integrity lost due to a hatch cover being removed    |
| during maintenance activities -                                              |
|                                                                              |
| At 0115 on 09/16/99. Limerick Generating Station Unit 2 experienced a loss   |
| of secondary containment integrity.  At the time of the event. the Standby   |
| Gas Treatment (SBGT) System was in service.  The Reactor Enclosure HVAC      |
| System was not in service due to maintenance activities. The SBGT System was |
| unable to maintain reactor enclosure pressure greater than 0.25 inches of    |
| vacuum water gauge per Technical Specifications due to a hatch cover being   |
| removed for maintenance inspection activities.  This event could have        |
| prevented the fulfillment of the safety function of structures or systems    |
| that are needed to control the release of radioactive materials or mitigate  |
| the consequences of an accident.  The hatch cover was reinstalled properly   |
| by 0126 and the SBGT System was able to draw a vacuum on the reactor         |
| enclosure area greater than 0.25 inches of vacuum water gauge.               |
|                                                                              |
| The licensee informed the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+