Event Notification Report for September 9, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           09/08/1999 - 09/09/1999

                              ** EVENT NUMBERS **

35790  36134  36135  36136  36137  36138  36139  

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   35790       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT      |NOTIFICATION DATE: 06/03/1999|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 14:44[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        06/02/1999|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        16:30[CDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  09/08/1999|
|    CITY:  PADUCAH                  REGION:  3  +-----------------------------+
|  COUNTY:  McCRACKEN                 STATE:  KY |PERSON          ORGANIZATION |
|LICENSE#:  GDP-1                 AGREEMENT:  Y  |DAVID HILLS          R3      |
|  DOCKET:  0707001                              |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  THOMAS WHITE                 |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|OCBA 76.120(c)(2)(i)     ACCID MT EQUIP FAILS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THREE SPRINKLER SYSTEMS DECLARED INOPERABLE DUE TO CORRODED HEADS (24-hour   |
| report)                                                                      |
|                                                                              |
| The following text is a portion of a facsimile received from Paducah:        |
|                                                                              |
| "On 06/02/99 at 1630 CDT, the Plant Shift Superintendent (PSS) was notified  |
| that numerous sprinkler heads were corroded, affecting 16 sprinkler systems  |
| in C-337 and one system in C-333, such that the ability of the sprinklers to |
| flow sufficient water was called into question.  Subsequently, these         |
| sprinkler systems were declared inoperable, and TSR-required actions         |
| establishing roving fire patrols were initiated.  This deficiency was        |
| detected during scheduled system inspections conducted by Fire Protection    |
| personnel.  Currently, functionality of the sprinkler heads has not been     |
| fully evaluated by Fire Protection personnel, and the remaining cascade      |
| buildings are currently being inspected, and if necessary, this report will  |
| be updated to identify any additional areas.                                 |
|                                                                              |
| "It has been determined that this event is reportable under                  |
| 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to     |
| function as designed."                                                       |
|                                                                              |
| The NRC resident inspector has been notified of this event.                  |
|                                                                              |
|                                                                              |
| * * * UPDATE AT 1022 EDT ON 06/04/99 FROM CAGE TO TROCINE * * *              |
|                                                                              |
| "Two sprinkler heads on system D-1 in C-337 and two sprinkler heads on       |
| system 27 in C-335 were identified to also be corroded.  These were          |
| identified to the PSS on 06/03/99 at 1600 CDT and 1601 CDT, respectively,    |
| and determined to require an update to this report by the PSS.               |
|                                                                              |
| "It has been determined that this event is reportable under                  |
| 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to     |
| function as designed."                                                       |
|                                                                              |
| Paducah personnel notified the NRC resident inspector of this update.  The   |
| NRC operations officer notified the R3DO (Hills) and NMSS EO (Combs).        |
|                                                                              |
| * * * UPDATE AT 2152 EDT ON 06/17/99 FROM WALKER TO POERTNER * * *           |
|                                                                              |
| "Three sprinkler heads on system C-15 and five sprinkler heads on system B-8 |
| in C-333 were identified to also be corroded.  The PSS was notified of this  |
| condition at 1300 CDT on 06/17/99 and determined that an update to this      |
| report was required."                                                        |
|                                                                              |
| "It has been determined that this event is reportable under                  |
| 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to     |
| function as designed."                                                       |
|                                                                              |
| Paducah personnel notified the NRC resident inspector of this update.  The   |
| NRC operations officer notified the R3DO (Madera).                           |
|                                                                              |
| * * * UPDATE 1440 EDT 6/18/1999 FROM UNDERWOOD TAKEN BY STRANSKY * * *       |
|                                                                              |
| "Two sprinkler heads on system C-15 and one sprinkler head on system B-8 in  |
| C-333 were identified to have corrosion.  The PSS was notified of this       |
| condition at 1350 CDT on 06/18/99.  The area of the fire patrol for system   |
| C-15 was expanded to include the two heads identified as corroded.  The one  |
| head on system B-8 was in the area already being patrolled.  The PSS         |
| determined that an update to this report was required."                      |
|                                                                              |
| The NRC resident inspector has been informed of this update.  Notified R3DO  |
| (Madera).                                                                    |
|                                                                              |
| * * * UPDATE 1315 EDT 6/25/1999 FROM WALKER TAKEN BY STRANSKY * * *          |
|                                                                              |
| "Two sprinkler heads on system D-8 and three sprinkler heads on system D-7   |
| in C-337 were identified to have corrosion.  The PSS was notified of the     |
| condition on system D-8 at 0125 CDT on 06/25/99 and at 1019 CDT on 06/25/99  |
| for system D-7.  Both systems were immediately declared inoperable and LCO   |
| fire patrol actions were implemented.  It was determined that an update to   |
| this report was required."                                                   |
|                                                                              |
| The NRC resident inspector has been informed of this update.  Notified R3DO  |
| (Jordan).                                                                    |
|                                                                              |
| * * * UPDATE 2119 EDT 7/30/1999 FROM CAGE TAKEN BY STRANSKY * * *            |
|                                                                              |
| "Five sprinkler heads and one sprinkler piping tee on C-337 system D-7 were  |
| identified to have corrosion. The PSS was notified of these corroded system  |
| parts and declared the system inoperable at 0931 CDT on 07/30/99.  LCO       |
| required fire patrols of the affected area were initiated.  The PSS          |
| determined that an update to this event report was required."                |
|                                                                              |
| The NRC resident inspector has been informed of this update.  Notified R3DO  |
| (Wright).                                                                    |
|                                                                              |
| * * * UPDATE 1655 EDT 7/31/1999 FROM WHITE TAKEN BY STRANSKY * * *           |
|                                                                              |
| "Two sprinkler heads on C-337 System D-1 were identified to have corrosion.  |
| The PSS was notified of these corroded system parts and declared the system  |
| inoperable at 1155 CDT on 7/31/99.  LCO required fire patrols of the         |
| affected area were initiated.  The PSS determined that an update to this     |
| report was required."                                                        |
|                                                                              |
| The NRC resident inspector has been informed of this update. Notified R3DO   |
| (Wright).                                                                    |
|                                                                              |
| * * * UPDATE 1546 EDT 8/10/1999 FROM WHITE TAKEN BY STRANSKY * * *           |
|                                                                              |
| "Two sprinkler heads on C-337 system C-15 were identified to have corrosion. |
| The PSS was notified of these corroded system parts and declared the system  |
| inoperable at 1130 CDT on 8/10/99.  LCO required fire patrols of the         |
| affected area were initiated.  The PSS determined that an update to this     |
| report was required."                                                        |
|                                                                              |
| The NRC resident inspector has been informed of this update. Notified R3DO   |
| (Burgess).                                                                   |
|                                                                              |
| * * * UPDATE AT 1154 EDT 8/22/99 FROM WALKER TO POERTNER * * *               |
|                                                                              |
| Four adjacent sprinkler heads on C-333 System B-1 were identified to have    |
| corrosion.  The PSS was notified of the corroded system parts and declared   |
| the system inoperable at 0918 CDT on 8/22/99.  LCO required fire patrols     |
| were initiated.  The PSS determined that an update to this report was        |
| required.                                                                    |
|                                                                              |
| It has been determined that this event is reportable under 10CFR76.120(c)(2) |
| as an event in which equipment is disabled or fails to function as           |
| designed.                                                                    |
|                                                                              |
| The NRC resident inspector will be notified.                                 |
|                                                                              |
| The NRC operations officer notified the R3DO (Clayton).                      |
|                                                                              |
| * * * UPDATE 2015 EDT ON 8/28/99 FROM W.F. GAGE TO S. SANDIN * * *           |
|                                                                              |
| The following information was provided as an update to this report:          |
|                                                                              |
| "Two adjacent sprinkler heads on C-337 System D-11 were identified to have   |
| corrosion.  The PSS was notified of these corroded system parts and declared |
| the system inoperable at 1420 [CDT] on 8/28/99.   LCO required fire patrols  |
| of the affected area were initiated. The PSS determined that an update to    |
| this report was required."                                                   |
|                                                                              |
| Paducah personnel informed the NRC resident inspector.  The NRC operations   |
| officer notified the R3DO (Leach) and NMSS EO (Piccone).                     |
|                                                                              |
| * * * UPDATE 2037 EDT ON 8/29/99 FROM KEVIN BEASLEY TO S. SANDIN * * *       |
|                                                                              |
| The following information was provided as an update to this report:          |
|                                                                              |
| "Two adjacent sprinkler heads on C-337 System D-15 were identified to have   |
| corrosion and the PSS declared the system inoperable at 0925 [CDT] on        |
| 8/29/99.  Also two adjacent heads on C-337 System D-10 were identified to    |
| have corrosion and the PSS declared the system inoperable at 1450.   LCO     |
| required fire patrols for both of the affected areas were initiated in the   |
| time frame required by TSR.  The PSS determined that an update to this       |
| report was required."                                                        |
|                                                                              |
| Paducah personnel informed the NRC resident inspector.  The NRC operations   |
| officer notified the R3DO (Leach) and NMSS EO (Piccone).                     |
|                                                                              |
| * * * UPDATE AT 0930 EDT ON 9/1/99  BY ERIC WALKER TO FANGIE JONES * * *     |
|                                                                              |
| Add two adjacent sprinkler heads on C-337 D-14.  Paducah personnel informed  |
| the NRC Resident Inspector.  The NRC operations officer notified the R3DO    |
| (David Hills) and NMSS (Robert Pierson).                                     |
|                                                                              |
| * * * UPDATE AT 1133 EDT ON 9/8/99  BY TOM WHITE TO FANGIE JONES * * *       |
|                                                                              |
| Add two adjacent sprinkler heads on C-331 System 26, system declared         |
| inoperable at 2155 CDT on 9/7/99. An LCO required fire patrol for the        |
| affected area was initiated in the time frame required by the TSR.  Paducah  |
| personnel informed the NRC Resident Inspector.  The NRC operations officer   |
| notified the R3DO (Monte Phillips) and NMSS (Josie Piccone).                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36134       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 09/08/1999|
|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 10:27[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        09/08/1999|
+------------------------------------------------+EVENT TIME:        06:10[CDT]|
| NRC NOTIFIED BY:  TIM GOLDEN                   |LAST UPDATE DATE:  09/08/1999|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HPCI SYSTEM DECLARED INOPERABLE                                              |
|                                                                              |
| The high pressure coolant injection (HPCI) system was declared inoperable    |
| after a unit operator observed that the HPCI system flow controller, located |
| on the control panel, had failed downscale. The licensee has begun           |
| troubleshooting activities to determine the nature of the controller         |
| failure. The NRC resident inspector has been informed of this event by the   |
| licensee.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   36135       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  METOREX                              |NOTIFICATION DATE: 09/08/1999|
|LICENSEE:  METOREX                              |NOTIFICATION TIME: 11:10[EDT]|
|    CITY:  EWING                    REGION:  1  |EVENT DATE:        09/08/1999|
|  COUNTY:                            STATE:  NJ |EVENT TIME:             [EDT]|
|LICENSE#:  29-30342-01           AGREEMENT:  N  |LAST UPDATE DATE:  09/08/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |TOM MOSLAK           R1      |
|                                                |JOSIE PICCONE        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JOHN PATTERSON               |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PACKAGE CONTAINING RADIOACTIVE SOURCES LOST DURING SHIPMENT                  |
|                                                                              |
| Mr. Patterson of Metorex contacted the NRC Headquarters Operations Center to |
| report that a package containing a device with two radioactive sources (60   |
| mCi of Cm-244 and 30 mCi of Am-241) has been lost during shipment by Federal |
| Express. The package left Metorex on 8/3/99, but failed to arrive at         |
| Envirosafe Services of Oregon, OH as of 8/26/99. The package was last        |
| scanned by Federal Express on 8/16/99 in Northwood, OH. The licensee has     |
| been in contact with the RSO for Federal Express (Dr. Roy Parker) regarding  |
| this shipment.                                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Hospital                                         |Event Number:   36136       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  McLAREN REGIONAL MEDICAL CENTER      |NOTIFICATION DATE: 09/08/1999|
|LICENSEE:  McLAREN REGIONAL MEDICAL CENTER      |NOTIFICATION TIME: 11:47[EDT]|
|    CITY:  FLINT                    REGION:  3  |EVENT DATE:        09/08/1999|
|  COUNTY:                            STATE:  MI |EVENT TIME:        08:00[EDT]|
|LICENSE#:  21-04171-04           AGREEMENT:  N  |LAST UPDATE DATE:  09/08/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MONTE PHILLIPS       R3      |
|                                                |JOSIE PICCONE        NMSS    |
+------------------------------------------------+JOSEPH GIITTER       IRO     |
| NRC NOTIFIED BY:  DOUGLAS SOUTHWELL            |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAAA 20.1906(d)           SURFACE CONT/ EXT RAD |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HOSPITAL RECEIVED PACKAGE THAT EXCEEDED REGULATORY LIMITS                    |
|                                                                              |
| During the receipt inspection of a package, containing Technetium-99m        |
| Myoview, it was determined that a surface survey reading was greater than    |
| the limit of a White 1 tag, the reading was 1.1 mR/hr.  A wipe reading had a |
| maximum of 23.75 dpm.  The hospital contacted the source pharmacy            |
| (Mallinckrodt of Saginaw, MI) who asked them to open the package for         |
| inspection.  The hospital opened the package and performed a wipe test of    |
| the contents and the inside of the container.  The results were negative     |
| with a maximum wipe of 62.5 dpm.  A surface survey determined that one of    |
| the pigs had a surface reading of 2 mR/hr, the pharmacy asked the hospital   |
| to mark it so that it could be discarded when it is returned.  They believe  |
| that the pig has developed a crack which makes it unusable.  The dose of     |
| Technetium-99m Myoview was not damaged.                                      |
|                                                                              |
| The hospital has notified NRC Region 3 DNMS (Debra Piskura).                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36137       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS           REGION:  1  |NOTIFICATION DATE: 09/08/1999|
|    UNIT:  [1] [2] []                STATE:  MD |NOTIFICATION TIME: 14:52[EDT]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        09/08/1999|
+------------------------------------------------+EVENT TIME:        13:05[EDT]|
| NRC NOTIFIED BY:  LAVATO                       |LAST UPDATE DATE:  09/08/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |TOM MOSLAK           R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE LICENSEE NOTIFIED THE MARYLAND DEPARTMENT OF THE ENVIRONMENT THAT THEY   |
| HAD EXCEEDED THEIR NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM (NPDES)   |
| PERMIT LIMITS                                                                |
|                                                                              |
| THEY DISCOVERED THAT TOTAL SUSPENDED SOLIDS IN A COMPOSITE SAMPLE OF         |
| EFFLUENT FROM THE SEWAGE TREATMENT PLANT WAS 68 MG/LITER, WHICH EXCEEDS THE  |
| NPDES PERMIT DAILY MAXIMUM VALUE OF 45 MG/LITER.  THE STATE WAS BEING        |
| NOTIFIED BY THE CHEMISTRY DEPARTMENT.                                        |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED.                                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36138       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM                    REGION:  1  |NOTIFICATION DATE: 09/08/1999|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 15:42[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/08/1999|
+------------------------------------------------+EVENT TIME:        14:05[EDT]|
| NRC NOTIFIED BY:  JONES                        |LAST UPDATE DATE:  09/08/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |TOM MOSLAK           R1      |
|10 CFR SECTION:                                 |ELINOR ADENSAM       NRR     |
|ADEG 50.72(b)(1)(ii)     DEGRAD COND DURING OP  |JOSEPH GIITTER       IRO     |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       80       Power Operation  |80       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE PLANT HAD REACTOR COOLANT LEAKAGE >25 GPM.                               |
|                                                                              |
| IN PREPARATION FOR RESIN SLUICING OPERATIONS ON THE "12" MIXED BED           |
| DEMINERLIZER, THE DEMINERLIZER WAS ISOLATED AND TAGGED.   WHILE THE          |
| DEMINERLIZER WAS BEING DRAINED, IT WAS IDENTIFIED THAT THE ISOLATION VALVE   |
| WAS LEAKING BY FOR TWO MINUTES AT A REACTOR COOLANT SYSTEM LEAKRATE OF       |
| APPROXIMATELY 80 GPM.  UPON IDENTIFICATION, THE LEAK WAS IMMEDIATELY         |
| ISOLATED.  TOTAL DISCHARGE WAS APPROXIMATELY 200 GALLONS TO THE PLANT'S      |
| RADIOACTIVE WASTE SYSTEM.  THE PLANT VENT RADIATION MONITOR "1R16"  WAS IN   |
| ALARM AND HAS SINCE CLEARED THE ALARM SETPOINT.   AT 1445 IT WAS IDENTIFIED  |
| THAT THIS DISCHARGE EXCEEDED THE UNUSUAL EVENT CRITERIA OF 25 GPM FOR        |
| IDENTIFIED LEAKAGE AND THE MAXIMUM PLANT VENT RELEASE RATE WAS APPROXIMATELY |
| 835 MICROCURIES/SEC.  PLANT CONDITIONS ARE STABLE AND AN INVESTIGATION IS    |
| ONGOING.  THERE IS NO RELEASE AT THIS TIME AND THE APPROXIMATE RELEASE RATE  |
| WAS ABOUT 1% OF LIMITS.                                                      |
|                                                                              |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   36139       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TURKEY POINT             REGION:  2  |NOTIFICATION DATE: 09/08/1999|
|    UNIT:  [3] [4] []                STATE:  FL |NOTIFICATION TIME: 23:12[EDT]|
|   RXTYPE: [3] W-3-LP,[4] W-3-LP                |EVENT DATE:        09/08/1999|
+------------------------------------------------+EVENT TIME:        22:30[EDT]|
| NRC NOTIFIED BY:  ANDRE DALL'AU                |LAST UPDATE DATE:  09/09/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|4     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOTH UNITS EXPERIENCED A TEMPORARY LOSS OF THE EMERGENCY RESPONSE DATA       |
| SYSTEM.                                                                      |
|                                                                              |
| "DISCOVERED @ 2230 ERDADS AND ERDS STOPPED UPDATING DATA @ 2200.  ERDS       |
| CALLED OUT OF SERVICE AND TROUBLESHOOTING UNDERWAY TO DETERMINE CAUSE.       |
| UNKNOWN AT THIS TIME IF FAILURE ASSOCIATED WITH Y2K.  SYSTEM STARTED         |
| UPDATING DUE TO TROUBLESHOOTING ACTIVITIES @ 2305."                          |
|                                                                              |
| THE  LICENSEE WILL INFORM THE NRC RESIDENT INSPECTOR.                        |
|                                                                              |
| * * * UPDATE 0313 9/9/1999 FROM DALL'AU TAKEN BY STRANSKY * * *              |
|                                                                              |
| "ERDS and ERDADS powered and declared functional at 2330 9/8/99. All         |
| troubleshooting and testing complete with ERDS and ERDADS declared back in   |
| service at 0250 9/9/99. Intermittent disk failures of the primary computer,  |
| not any Y2K related failures, were determined to be the cause of the loss of |
| data."                                                                       |
|                                                                              |
| The NRC resident inspector will be informed of this update. Notified R2DO    |
| (Haag).                                                                      |
+------------------------------------------------------------------------------+