Event Notification Report for August 17, 1999
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
08/16/1999 - 08/17/1999
** EVENT NUMBERS **
35975 36033 36034 36035 36036
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35975 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PILGRIM REGION: 1 |NOTIFICATION DATE: 07/30/1999|
| UNIT: [1] [] [] STATE: MA |NOTIFICATION TIME: 20:24[EDT]|
| RXTYPE: [1] GE-3 |EVENT DATE: 07/30/1999|
+------------------------------------------------+EVENT TIME: 19:30[EDT]|
| NRC NOTIFIED BY: DAVE NOYES |LAST UPDATE DATE: 08/16/1999|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JOHN KINNEMAN R1 |
|10 CFR SECTION: | |
|AUNA 50.72(b)(1)(ii)(A) UNANALYZED COND OP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SALT SERVICE WATER SYSTEM EXCEEDED MAXIMUM DESIGN TEMPERATURE |
| |
| The 'A' train of the salt service water system was declared inoperable when |
| the intake structure temperature exceeded the maximum design temperature of |
| 105�F. The highest actual temperature reached was 106�F, which occurred for |
| approximately 15 minutes, until operators were able to reduce the |
| temperature by realigning the salt service water system. The current intake |
| structure temperature is 100�F. |
| |
| The NRC resident inspector has been informed of this event by the licensee. |
| |
| ******************** UPDATE AT 1448 ON 08/16/99 FROM VINNIE FALLACARA TO |
| TROCINE ******************** |
| |
| After further evaluation based on NUREG 1022, Revision 1, the licensee |
| concluded that this event was not reportable. The temperature exceeded the |
| design temperature for only a short period {well within the limiting |
| condition for operation (LCO) time frame}. Only one side of the system was |
| affected, and this was not a common mode type of event. The event was |
| covered under the LCO, and the LCO actions were met. Therefore, the |
| licensee is retracting this event notification. |
| |
| The licensee plans to notify the NRC resident inspector. The NRC operations |
| officer notified the R1DO (Eselgroth). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 36033 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: U.S. ARMY |NOTIFICATION DATE: 08/16/1999|
|LICENSEE: U.S. ARMY |NOTIFICATION TIME: 17:04[EDT]|
| CITY: Rock Island REGION: 3 |EVENT DATE: 08/16/1999|
| COUNTY: STATE: IL |EVENT TIME: [CDT]|
|LICENSE#: 12-00722-06 AGREEMENT: Y |LAST UPDATE DATE: 08/16/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |BRENT CLAYTON R3 |
| |PETER ESELGROTH R1 |
+------------------------------------------------+JOHN HICKEY NMSS |
| NRC NOTIFIED BY: GAVIN ZIEGLER | |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|IBAC 30.50(b)(1)(i) ACCESS DENIED >24 HRS | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNPLANNED CONTAMINATION IN AN ARMS ROOM AT FORT DRUM (A U.S. ARMY FACILITY) |
| LOCATED IN WATERTOWN, NEW YORK |
| |
| At 1400 EDT on 08/12/99, individuals located in an arms room were performing |
| maintenance on an M224 mortar range indicator when one of the four sources |
| broke causing an unplanned contamination. The sources each contained 0.8 Ci |
| of tritium. Two individuals were close by, and two bioassays were |
| performed. The bioassay results are currently pending. However, the |
| following wipe test results were received today (08/16/99): |
| |
| 6,300,000 dpm at the site of the broken source, |
| 1,358,000 dpm on the mortar housing, |
| 31,000 dpm on the mortar, |
| 74,000 dpm on an adjacent table top, |
| 74,000 dpm (highest reading) on a wall, and |
| 34,000 - 35,000 dpm on four walls. |
| |
| It was also reported that the maintenance activities should have occurred in |
| a maintenance shop rather than in the arms room (which is used for storage). |
| As a result, there may be additional items with contamination. The arms |
| room has been cordoned off. |
| |
| (Call the NRC operations officer for a contact telephone number.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36034 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 08/14/1999|
| UNIT: [1] [2] [] STATE: PA |NOTIFICATION TIME: 15:54[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 08/14/1999|
+------------------------------------------------+EVENT TIME: 15:00[EDT]|
| NRC NOTIFIED BY: GRANT FERNSLER |LAST UPDATE DATE: 08/16/1999|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |HAROLD GRAY R1DO |
|10 CFR SECTION: | |
|AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNAVAILABILITY OF NOTIFICATION SYSTEMS FOR PAGER ACTIVATION |
| |
| The tele-notification system utilized for pager activation and the backup |
| alpha-mate paging system were not available. Manual paging was available |
| for emergency notification. |
| |
| The licensee plans to notify the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36035 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 08/14/1999|
| UNIT: [2] [3] [] STATE: PA |NOTIFICATION TIME: 20:41[EDT]|
| RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 08/14/1999|
+------------------------------------------------+EVENT TIME: 20:05[EDT]|
| NRC NOTIFIED BY: PAT NAVIN |LAST UPDATE DATE: 08/16/1999|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |HAROLD GRAY R1DO |
|10 CFR SECTION: | |
|AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 N Y 100 Power Operation |100 Power Operation |
|3 N Y 95 Power Operation |95 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNAVAILABILITY OF THE EMERGENCY NOTIFICATION SYSTEM (ENS) LINE AND 16 |
| EVACUATION SIRENS |
| |
| The licensee reported that the emergency notification system line was out of |
| service as well as 14 of 26 evacuation sirens in York County and 2 of 35 |
| evacuation sirens in Lancaster County. |
| |
| The licensee plans to notify the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36036 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HARRIS REGION: 2 |NOTIFICATION DATE: 08/16/1999|
| UNIT: [1] [] [] STATE: NC |NOTIFICATION TIME: 21:06[EDT]|
| RXTYPE: [1] W-3-LP |EVENT DATE: 08/14/1999|
+------------------------------------------------+EVENT TIME: 16:00[EDT]|
| NRC NOTIFIED BY: MAURICE GRIFFIN |LAST UPDATE DATE: 08/16/1999|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CHARLES OGLE R2 |
|10 CFR SECTION: | |
|AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF EMERGENCY SIRENS IN HARNETT COUNTY DUE TO A LIGHTNING STRIKE |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "All sirens in Harnett County were lost from 1600 to 1730 on 08/14/99 ... |
| due to a lightning strike [that took out a 911 repeater]. The backup |
| repeater was placed in service at 1730 [on 08/14/99]. The primary repeater |
| was placed in service at 1200 on 08/16/99. The backup repeater is not |
| tested routinely, and it is unknown if it would have actuated the sirens |
| from 1730 [on] 08/14/99 until 1200 [on] 08/16/99. This feature will be |
| tested tomorrow to determine if the sirens were operable on the backup |
| repeater." |
| |
| The licensee stated that there are a total of 81 sirens associated with the |
| Harris facility and that all 7 sirens in Harnett County were lost. This |
| event was determined to be reportable at 2040 on 08/16/99. |
| |
| The licensee plans to notify the NRC resident inspector. |
+------------------------------------------------------------------------------+