|Power Reactor                                    |Event Number:   35849       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY                   REGION:  2  |NOTIFICATION DATE: 06/21/1999|
|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 18:53[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        06/21/1999|
+------------------------------------------------+EVENT TIME:        16:57[CDT]|
| NRC NOTIFIED BY:  BOWEN                        |LAST UPDATE DATE:  06/21/1999|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(1)(i)(A)   PLANT S/D REQD BY TS   |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| THE PLANT ENTERED TS REQUIRED SHUT DOWN DUE TO LOSS OF TWO STEAM FLOW        |
| CHANNELS ON THE "A" STEAM GENERATOR.                                         |
|                                                                              |
| PRIOR TO THIS EVENT THERE WAS A BROKEN SENSING LINE ON THE  "B" STEAM        |
| GENERATOR STEAM FLOW CHANNEL WHICH REQUIRED PUTTING THE CHANNEL 3 STEAM      |
| FLOWS ON ALL THREE STEAM GENERATORS IN TEST.   TODAY @ 1657 CHANNEL 4 ON THE |
| "A" STEAM GENERATOR FAILED.  THERE ARE TWO STEAM FLOW CHANNELS PER STEAM     |
| GENERATOR AND TECHNICAL SPECIFICATIONS REQUIRE ONE OF THE TWO FLOW CHANNELS  |
| TO BE AVAILABLE.  SINCE  CHANNELS 3 AND 4 ON THE "A" STEAM GENERATOR ARE NOT |
| AVAILABLE, THE PLANT ENTERED TS LCO 3.0.3 WHICH GIVES THEM 7 HRS. TO BE IN   |
| HOT STANDBY, 6 HOURS TO HOT SHUTDOWN AND THE FOLLOWING 24 HOURS TO COLD      |
| SHUTDOWN.  THE FEED PUMP SPEED CONTROL AND THE "A" STEAM GENERATOR FLOW      |
| CONTROL VALVE WERE PLACED IN MANUAL AND LEVELS WERE STABILIZED.  THEY CAN    |
| EXIT THE LCO ACTION STATEMENT IF THEY  TAKE CHANNEL 3 OUT OF TEST ON "A"     |
| STEAM GENERATOR AND RETURN IT TO SERVICE.                                    |
|                                                                              |
| THE RESIDENT INSPECTOR WILL BE INFORMED.                                     |
|                                                                              |
| *** UPDATE ON 6/21/99 @ 2017 BY BOWEN TO GOULD ***                           |
|                                                                              |
| THEY TOOK THE CHANNEL 3 STEAM FLOW OUT OF TEST AND RETURNED IT TO SERVICE AT |
| 1807 AND EXITED THE LCO ACTION STATEMENT.                                    |
|                                                                              |
| THE RESIDENT WILL BE NOTIFIED.  REG2 RDO (JULIAN)                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   35850       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WILCOX ASSOCIATES                    |NOTIFICATION DATE: 06/21/1999|
|LICENSEE:  WILCOX ASSOCIATES                    |NOTIFICATION TIME: 19:06[EDT]|
|    CITY:  CADILAC                  REGION:  3  |EVENT DATE:        06/21/1999|
|  COUNTY:                            STATE:  MI |EVENT TIME:        15:30[EDT]|
|LICENSE#:  21-23314-01           AGREEMENT:  N  |LAST UPDATE DATE:  06/21/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MIKE JORDAN          R3      |
|                                                |                             |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  PIERCE                       |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NDAM                     DAMAGED GAUGE/DEVICE   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| TROXLER GAUGE DAMAGED.                                                       |
|                                                                              |
| A MODEL 3440A TROXLER GAUGE CONTAINING 8 MILLICURIES OF CESIUM-137 AND 40    |
| MILLICURIES OF AMERICIUM-241 WAS DAMAGED WHEN IT WAS RUN OVER ON U.S. ROUTE  |
| 23 NEAR PAWAS, MI.  THERE APPEARS TO BE NO DAMAGE TO THE SOURCE.   THEY ARE  |
| PLANNING ON PUTTING IT INTO ITS STORAGE CASE AND TAKING IT BACK TO THEIR     |
| FACILITIES.                                                                  |
+------------------------------------------------------------------------------+