Event Notification Report for June 14, 1999
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
06/11/1999 - 06/14/1999
** EVENT NUMBERS **
35132 35158 35688 35812 35814 35815 35816 35817 35818
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35132 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 12/10/1998|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 05:10[EST]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 12/09/1998|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 22:45[EST]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 06/11/1999|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |MARK RING R3 |
| DOCKET: 0707002 |WAYNE HODGES NMSS |
+------------------------------------------------+JOSEPH GIITTER IRD |
| NRC NOTIFIED BY: ERIC SPAETH | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: ALE | |
|10 CFR SECTION: | |
|AAEC 50.72 (a) (1) (I) EMERGENCY DECLARED | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| FIRE DAMAGE TO EQUIPMENT CONTAINING RADIOACTIVE MATERIAL |
| |
| On Wednesday December 9, 1998, at 0610 EST a motor fire occurred in the |
| X-326 process building on cell 25-7-2. The fire was put out by the plant |
| fire department. The fire involved lubricating oil in an electrical motor |
| that drives compressors. The fire was limited to a single housing |
| containing the affected equipment. However the fire spread to additional |
| motors and equipment within the cell housing. Damage to the equipment and |
| piping caused the primary containment to be breached. |
| |
| At 2245 EST the Plant Shift Superintendent determined that this event was |
| reportable under 10CFR76.120(c)(4). The fire damaged the radioactive |
| material container (process gas piping) and the equipment contained |
| radioactive material greater than 5 ALls (5 microcuries or 2.2 grams |
| U-235). |
| |
| The certificate holder notified the NRC Resident Inspector, the local DOE |
| representative, the state of Ohio, and issued a press release. |
| |
| See Event # 35130 and 35131. |
| |
| *** UPDATE ON 6/11/99 @ 1558 BY SPAETH TO GOULD *** |
| |
| SUBSEQUENT TO THE TERMINATION OF THIS EVENT ON 12/09/98, THE USEC HAS |
| DETERMINED ON 6/11/99 @ 1502 THAT THIS EVENT MET THE CRITERIA FOR AN "ALERT" |
| EMERGENCY CLASSIFICATION. THE DECLARATION OF AN ALERT WOULD HAVE BEEN |
| REPORTABLE IN ACCORDANCE WITH 10CFR76.120(a)(4), BUT WAS NOT REPORTED AT THE |
| TIME OF THE EVENT BECAUSE AN "ALERT" WAS NOT DECLARED. IN ACCORDANCE WITH |
| THE GUIDANCE PROVIDED IN NUREG-1022, REV 1, USEC IS UPDATING THIS |
| NOTIFICATION TO INDICATE THAT THIS EVENT ALSO MET 10CFR76.120(a)(4) |
| REPORTING CRITERIA. |
| |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED. |
| |
| THE REG 3 RDO (JORGENSEN), NMSS EO (SHERR) AND IRO (CONGEL) WERE NOTIFIED. |
| |
| THE FOLLOWING FEDERAL AGENCIES WERE INFORMED OF THIS UPDATE VIA FAX ON |
| 6/12/99: |
| |
| FEMA, DOE, USDA, HHS (CDC), EPA, AND DOT (NRC). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 35158 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: USAF RADIOSOTOPE COMMITTEE |NOTIFICATION DATE: 12/16/1998|
|LICENSEE: UNITED STATES AIR FORCE |NOTIFICATION TIME: 17:35[EST]|
| CITY: OKLAHOMA CITY REGION: 4 |EVENT DATE: 11/03/1998|
| COUNTY: STATE: OK |EVENT TIME: 08:00[CST]|
|LICENSE#: 42-23539-01AF AGREEMENT: N |LAST UPDATE DATE: 06/11/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |IAN BARNES R4 |
| |WILLIAM KANE NMSS |
+------------------------------------------------+EPA, DOE, FEMA, USDA FAX |
| NRC NOTIFIED BY: Major HICKS |HHS, DOT (NRC) |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NINF INFORMATION ONLY | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| RADIOACTIVE THORIUM MAGNESIUM USAF AIRCRAFT PARTS FOUND IN SCRAPYARD |
| |
| At 0800 CST on 11/03/98, a C&C Alloy Company representative notified the |
| Tinker Air Force Base (TAFB) Bioenvironmental Engineering Office (BEO) that |
| aircraft parts they had purchased from the TAFB Defense Reutilization |
| Management Office may be radioactive. The BEO sent representatives to the |
| C&C Alloy scrapyard in Oklahoma City to survey a crate of scrap metal which |
| contained radioactive parts. Radiation levels of the scrap metal were |
| reading twice as much as background levels. The metal had been cut up into |
| small pieces and is believed to be magnesium thorium panels. No personnel |
| had been exposed to respirable particles during the cutting process. The |
| crate of material has been returned to TAFB for proper disposal. The BEO |
| plans to establish by 01/15/99 a procedure to survey scrap metal before it |
| leaves TAFB. The BEO plans to notify Oklahoma authorities and request that |
| the Air Force Health Physics Branch (Brooks Air Force Base, San Antonio, TX) |
| provide a radiation survey team if C&C Alloy requests that a survey of their |
| scrapyard be performed. |
| |
| The USAF Radioisotope Committee was informed of this event at 1300 CST on |
| 12/16/98. |
| |
| *** UPDATE ON 6/11/99 @ 1242 BY HICKS TO GOULD *** FINAL REPORT |
| |
| C&C ALLOY RETURNED ALL RADIOACTIVE MATERIAL TO THE AIR FORCE AND DECLINED |
| THE RADIATION SURVEY. A GATE MONITOR WAS INSTALLED FOR THE DEFENSE |
| REUTILIZATION MANAGEMENT OFFICE(DRMO) TO MONITOR ALL SCRAP METAL, AND PRIOR |
| TO ITS INSTALLATION, SCRAP METAL WAS SURVEYED WITH HAND-HELD RADIATION |
| DETECTORS. PERSONNEL WILL BE EDUCATED ON THE USE OF THE GATE MONITOR. |
| |
| THE METAL WAS IDENTIFIED AS COMING FROM A T-53 GAS TURBINE ENGINE, POSSIBLY |
| USED IN THE F MODEL UN-1 HELICOPTER. THE MATERIAL WAS MANUFACTURED BY |
| ALLIED SIGNAL AEROSPACE AND WAS IDENTIFIED AS CONTAINING 2 TO 3% BY WEIGHT |
| OF THORIUM 232. THIS ALLOY MEETS THE EXEMPT REQUIREMENTS OF |
| 10CFR40.13(c)(4). |
| |
| NOTIFIED REG 4 RDO(ANDREWS), NMSS EO(COOL). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 35688 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: USAF RADIOISOTOPE COMMITTEE |NOTIFICATION DATE: 05/07/1999|
|LICENSEE: USAF RADIOISOTOPE COMMITTEE |NOTIFICATION TIME: 10:45[EDT]|
| CITY: Sumptor REGION: 2 |EVENT DATE: 05/07/1999|
| COUNTY: STATE: SC |EVENT TIME: 09:38[EDT]|
|LICENSE#: 42-23539-01AF AGREEMENT: Y |LAST UPDATE DATE: 06/11/1999|
| DOCKET: 03028641 |+----------------------------+
| |PERSON ORGANIZATION |
| |CHRIS CHRISTENSEN R2 |
| |BILL JONES R4 |
+------------------------------------------------+DON COOL NMSS |
| NRC NOTIFIED BY: MAJOR JAMES HICKS |FRANK CONGEL IRO |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY OF A MISSING CHEMICAL AGENT MONITOR CONTAINING 15 mCi OF NICKEL-63 |
| FROM SHAW AIR FORCE BASE LOCATED IN SUMTER, SOUTH CAROLINA |
| |
| At 0938 on 05/07/99, Shaw Air Force Base (AFB) located in Sumter, South |
| Carolina, notified the U.S. Air Force Radioisotope Committee located at |
| Bolling AFB located in Washington D.C. of a missing chemical agent monitor |
| (CAM) containing a 15-mCi nickel-63 source. |
| |
| On 04/27/99, the base radiation safety officer (RSO) at Shaw AFB conducted |
| an inventory of CAMs located in building #1981. The correct number of CAMs |
| were there, but one had the wrong serial number. Examination of previous |
| inventories shows one CAM with a different serial number. The building had |
| been searched with no success. The 20CES/CEX RSO has no explanation for the |
| different serial number on one CAM or where the correct CAM may be located. |
| |
| |
| It is suspected that the CAM may have been exchanged with another Air Force |
| Unit or may have been sent off for calibration. At this time, the U.S. Air |
| Force Radioisotope Committee believes that the CAM is still in Air Force |
| possession. Past shipping records will be researched, and calibration labs |
| that serve Shaw AFB will be notified. The completion time for these actions |
| is currently estimated to be 06/07/99. |
| |
| Call the NRC Operations Officer for a licensee contact telephone number. |
| |
| The licensee plans to notify the NRC Region 4 office and plans to issue a |
| 30-day written report. |
| |
| *** UPDATE ON 6/11/99 @ 1242 BY HICKS TO GOULD *** INTERIM REPORT |
| |
| MISSING CAM SERIAL NUMBER: CAN-C-04646 |
| |
| RADIOACTIVITY MATERIAL CONTAINED: 10 mCi OF Ni-63 |
| |
| ACTIVITY: 0.05 Ci |
| |
| CHEMICAL AND PHYSICAL FORM: SOLID |
| |
| A SERIAL NUMBER DISCREPANCY WAS NOTED DURING A SEMIANNUAL CAM INVENTORY |
| CONDUCTED 4/27/99. THE PREVIOUS INVENTORY CONDUCTED 10/98 INDICATED NO |
| DISCREPANCIES. |
| |
| A DISPOSITION, OR PROBABLE DISPOSITION, OF THE MATERIAL IS UNDETERMINABLE. |
| |
| THERE EXISTS THE POSSIBILITY THAT CALIBRATION SERVICES MAY HAVE SWAPPED OUT |
| THE CAM WITH ANOTHER MONITOR. ALSO, A POLICE INVESTIGATION MAY BE REQUIRED |
| SINCE THE DEVICE IS WORTH OVER $3,000.00. |
| |
| NOTIFIED REG 2 RDO(BONSER), REG 4 RDO(ANDREWS), AND NMSS EO(COOL). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35812 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 06/10/1999|
| UNIT: [2] [] [] STATE: PA |NOTIFICATION TIME: 15:29[EDT]|
| RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 06/10/1999|
+------------------------------------------------+EVENT TIME: 14:30[EDT]|
| NRC NOTIFIED BY: CAMPBELL |LAST UPDATE DATE: 06/11/1999|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JOHN CARUSO R1 |
|10 CFR SECTION: | |
|AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PLANT LOST THEIR SAFETY PARAMETER DISPLAY SYSTEM (SPDS) |
| |
| A HARDWARE FAILURE OCCURRED ON THE UNIT 2 PLANT PROCESS COMPUTER SYSTEM. |
| THIS RESULTED IN THE LOSS OF THE SPDS, WHICH IS ONE METHOD USED FOR |
| EMERGENCY ASSESSMENT. ALL THE CONTROL ROOM INDICATIONS ARE OPERABLE AND |
| AVAILABLE FOR EMERGENCY ASSESSMENT. |
| |
| THE RESIDENT INSPECTOR WAS NOTIFIED. |
| |
| * * * UPDATE AT 0250 ON 06/11/99 BY EILOLA, TAKEN BY WEAVER * * * |
| |
| THE HARDWARE FAILURE HAS BEEN REPAIRED AND THE SYSTEM HAS BEEN RETURNED TO |
| SERVICE. THE LICENSEE WILL NOTIFY THE NRC RESIDENT INSPECTOR. THE |
| OPERATIONS OFFICER NOTIFIED THE R1DO (CARUSO). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35814 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 06/11/1999|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 17:42[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 06/11/1999|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 13:45[EDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 06/11/1999|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |BRUCE JORGENSEN R3 |
| DOCKET: 0707002 |TED SHERR NMSS |
+------------------------------------------------+FRANK CONGEL IRO |
| NRC NOTIFIED BY: SPAETH | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NBNL RESPONSE-BULLETIN | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 4 HOUR 91-01 BULLETIN |
| |
| THE SITE REPORTED THAT AT 1345, OPERATIONS PERSONNEL DISCOVERED STANDING |
| WATER UNDER AUTOCLAVE #6 IN THE X-343, FEED AND SAMPLING FACILITY. STANDING |
| WATER IS AN INDICATION THAT A DRAIN UNDER THE AUTOCLAVE WAS PLUGGED. THE |
| PLUGGED DRAIN IS NOT THE AUTOCLAVE DRAIN, BUT THE CONTAINMENT PIT UNDER THE |
| AUTOCLAVE. THIS CONDITION IS ANALYZED IN THE NUCLEAR CRITICALITY SAFETY |
| EVALUATION, NCSE-0343_002.001 CONTINGENCY EVENT 6.3a, WHICH STATES IN PART, |
| "THE AUTOCLAVES ARE MOUNTED INSIDE LARGE CONCRETE PITS, WHICH ARE NORMALLY |
| DRY AND ARE PREVENTED FROM ACCUMULATING WATER FROM ANY SOURCE BY A 4 INCH |
| DRAIN." |
| |
| THE NUCLEAR CRITICALITY SAFETY (NCS) STAFF DETERMINED THAT A NUCLEAR |
| CRITICALITY SAFETY APPROVAL FOR THIS OPERATION WAS DEFICIENT IN THAT IT |
| FAILED TO IDENTIFY THE CONTROLS NECESSARY TO MAINTAIN THE ANALYZED |
| CONDITION. BUILDING AND NCS PERSONNEL HAVE DETERMINED THAT NO OTHER SIMILAR |
| CONDITIONS EXISTS. |
| |
| SAFETY SIGNIFICANCE IS LOW, THERE ARE NO CREDIBLE PATHWAYS TO CRITICALITY |
| AND THERE IS NO URANIUM IN THE PIT. |
| |
| MEASURES WERE PUT IN PLACE TO REGAIN COMPLIANCE AND ADMINISTRATIVE CONTROLS |
| IMPLEMENTED TO ASSURE COMPLIANCE IS MAINTAINED IN THE FUTURE. |
| |
| THE NRC RESIDENT INSPECTOR WILL BE INFORMED ALONG WITH THE DOE |
| REPRESENTATIVE. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35815 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK REGION: 1 |NOTIFICATION DATE: 06/11/1999|
| UNIT: [1] [] [] STATE: PA |NOTIFICATION TIME: 22:50[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 06/11/1999|
+------------------------------------------------+EVENT TIME: 19:20[EDT]|
| NRC NOTIFIED BY: DOUGHDRTY |LAST UPDATE DATE: 06/11/1999|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CURTIS COWGILL R1 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(ii) RPS ACTUATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 A/R Y 100 Power Operation |0 Hot Standby |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PLANT HAD A REACTOR SCRAM FROM 100% POWER DUE TO PERSONNEL ERROR. |
| |
| THE UNIT 1 REACTOR SCRAMMED ON A "TURBINE CONTROL VALVE FAST CLOSURE" RPS |
| SIGNAL DURING THE PERFORMANCE OF THE "BACKUP OVERSPEED AND POWER LOAD |
| UNBALANCE TEST". |
| THE CAUSE OF THE SCRAM WAS OPERATOR ERROR. THE FOLLOWING ESF ISOLATIONS |
| OCCURRED ON A VALID WIDE RANGE LEVEL "2" OF -38 INCHES: REACTOR WATER |
| CLEANUP, REACTOR ENCLOSURE SECONDARY CONTAINMENT HVAC, AND CONTAINMENT LEAK |
| DETECTION. ALL ISOLATIONS HAVE BEEN RESET. ALL RODS FULLY INSERTED, NO |
| INJECTION OCCURRED AND NO SAFETY/RELIEF VALVES LIFTED. THE HEAT SINK IS THE |
| MAIN CONDENSER. |
| |
| THE RESIDENT INSPECTOR WAS NOTIFIED. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 35816 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 06/12/1999|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 06:03[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 06/10/1999|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 16:33[CDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 06/12/1999|
| CITY: PADUCAH REGION: 3 +-----------------------------+
| COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION |
|LICENSE#: GDP-1 AGREEMENT: Y |BRUCE JORGENSEN R3 |
| DOCKET: 0707001 |TED SHERR NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: M.C. MAURER | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|OCBA 76.120(c)(2)(i) ACCID MT EQUIP FAILS | |
|OCBB 76.120(c)(2)(ii) EQUIP DISABLED/FAILS | |
|OCBC 76.120(c)(2)(iii) REDUNDANT EQUIP INOP | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF CRITICALITY ACCIDENT ALARM SYSTEM DURING MAINTENANCE |
| |
| "At 1633 CDT on 6/10/99, electricians were performing scheduled maintenance |
| on the C-400 building criticality accident alarm system (CAAS). During this |
| maintenance activity, circuit breaker EP1 in C-400 was opened resulting in a |
| system trouble alarm on the C-409 building 'AE' CAAS cluster. TSR LCO |
| actions were implemented for the C-409 facility due to the unknown cause of |
| the trouble alarm. After further review of this maintenance activity, there |
| is evidence that control power for the CAAS building horns in C-409 and |
| C-720-M was lost for approximately four hours during the subject maintenance |
| evolution. CAAS detectability and C-409 local CAAS horn operability were |
| not affected by the loss of control power. |
| |
| "It has been determined that this event is reportable under |
| 10CFR76.120(c)(2) as an event in which equipment is disabled or fails to |
| function as designed. |
| |
| "The NRC resident inspector has been notified of this event." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35817 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA REGION: 2 |NOTIFICATION DATE: 06/12/1999|
| UNIT: [] [2] [] STATE: SC |NOTIFICATION TIME: 16:58[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 06/12/1999|
+------------------------------------------------+EVENT TIME: 14:12[EDT]|
| NRC NOTIFIED BY: RUDD |LAST UPDATE DATE: 06/12/1999|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |BRIAN BONSER R2 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N N 0 Hot Shutdown |0 Hot Shutdown |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PLANT HAD A STEAM GENERATOR HI-HI (P14) LEVEL SIGNAL. |
| |
| UPON OPENING THE "2A" STEAM GENERATOR MSIV PER PROCEDURE, A SUBSEQUENT STEAM |
| GENERATOR LEVEL SWELL OCCURRED RESULTING IN A P14 (STEAM GENERATOR HI-HI |
| LEVEL) SIGNAL. NO COMPONENTS CHANGED STATE SINCE THEY WERE ALREADY |
| POSITIONED(i.e. CLOSED OR TRIPPED) BASED ON PLANT CONDITION OF MODE 4. THE |
| CAUSE APPEARS TO BE A PROCEDURAL DEFICIENCY, WHICH WILL BE CORRECTED WITH A |
| PROCEDURE CHANGE. |
| |
| THE RESIDENT INSPECTOR WILL BE NOTIFIED. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35818 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 06/12/1999|
| UNIT: [] [2] [] STATE: AL |NOTIFICATION TIME: 23:44[EDT]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 06/12/1999|
+------------------------------------------------+EVENT TIME: 21:47[CDT]|
| NRC NOTIFIED BY: HAWKINS |LAST UPDATE DATE: 06/12/1999|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |BRIAN BONSER R2 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(ii) RPS ACTUATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 M/R Y 100 Power Operation |0 Hot Standby |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| THE PLANT HAD A MANUAL REACTOR TRIP FROM 100% POWER. |
| |
| A MANUAL REACTOR TRIP WAS INITIATED BECAUSE OF A LOSS OF CONDENSER VACUUM |
| (CAUSE UNKNOWN AND BEING INVESTIGATED). ALL RODS FULLY INSERTED, NO ECCS |
| INJECTION INITIATED AND NO SAFETY OR RELIEF VALVES LIFTED. AUXILIARY |
| FEEDWATER STARTED AS EXPECTED FOLLOWING THE REACTOR TRIP AND THEY ARE USING |
| THE STEAM GENERATORS VIA THE STEAM DUMPS AS A HEAT SINK. ALL SYSTEMS |
| OPERATED SATISFACTORILY FOLLOWING THE TRIP WITH THE EXCEPTION OF THE M-35 |
| INTERMEDIATE RANGE CHANNEL, WHICH FAILED LOW. THE CAUSE OF THIS FAILURE IS |
| ALSO BEING INVESTIGATED. |
| |
| THE RESIDENT INSPECTOR WAS NOTIFIED. |
+------------------------------------------------------------------------------+