Event Notification Report for April 2, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 04/01/1999 - 04/02/1999 ** EVENT NUMBERS ** 35536 35538 35539 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 35536 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: UNIV. OF MINNESOTA, MINNEAPOLIS |NOTIFICATION DATE: 03/31/1999| |LICENSEE: UNIV. OF MINNESOTA, MINNEAPOLIS |NOTIFICATION TIME: 17:20[EST]| | CITY: MINNEAPOLIS REGION: 3 |EVENT DATE: 03/31/1999| | COUNTY: STATE: MN |EVENT TIME: 14:30[CST]| |LICENSE#: 22-00187-46 AGREEMENT: N |LAST UPDATE DATE: 04/01/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |MARK RING R3 | | |LARRY CAMPER NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: JERRY STAIGER | | | HQ OPS OFFICER: JOHN MacKINNON | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |BAAA 20.1906(d) SURFACE CONT/ EXT RAD | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | Tritium contamination was found on the bottom of a package delivered by | | FEDEX to the University of Minnesota Duluth campus. | | | | A package containing Phosphorus-33 delivered by FEDEX, (origin Amersham of | | Chicago), to the University of Minnesota, Duluth campus was found to have | | Tritium contamination only on the bottom of the package. Swipes of the | | package were taken twice and each time only contamination was found on the | | bottom of the package. The contamination level of each swipe was 50,000 DPM. | | The package was double bagged and the carpeting on which the package was | | resting was covered to prevent spread of contamination. The RSO for the | | University of Minnesota Minneapolis campus contacted the Amersham RSO, | | located in Chicago, IL., and informed him of this incident. The RSO for the | | University of Minnesota Minneapolis campus said that they were going to take | | another swipe of the package tomorrow morning (04/01/99) and take a reading | | of the swipe to make sure that the contamination of the package is from | | Tritium. The University of Minnesota at Duluth only received one package | | from FEDEX so the Tritium contamination of the bottom of the package did not | | come from the carpeting of the floor. | | | | Contact the HOO for contact numbers. | | | | * * * UPDATE 1050EST ON 4/1/99 FROM J. STAIGER TO S.SANDIN * * * | | | | The licensee is retracting this event after confirming that the | | scintillation counter response was due to chemical luminescence rather than | | tritium contamination. The licensee discussed this with R3(Jones) and | | notified the Amersham RSO as well as FEDEX. Notified R3DO (Ring). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35538 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: NORTH ANNA REGION: 2 |NOTIFICATION DATE: 04/01/1999| | UNIT: [1] [2] [] STATE: VA |NOTIFICATION TIME: 16:01[EST]| | RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 04/01/1999| +------------------------------------------------+EVENT TIME: 15:50[EST]| | NRC NOTIFIED BY: K. D. DEVOR |LAST UPDATE DATE: 04/01/1999| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |CHARLES OGLE R2 | |10 CFR SECTION: | | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | POSSIBLE GAS BINDING OF CHARGING PUMPS DURING CONTROL ROOM FIRE | | | | "Engineering has identified the possibility of equipment failure during an | | Appendix 'R' control room fire leading to gas binding of all charging pumps. | | This condition places [both] units outside of Appendix 'R' design basis. | | | | "Compensatory actions: 1) O-FCA-1 [procedure is] being changed to address | | this condition (Fire Contingency Action, Control Room Fire); 2) establishing | | continuous fire watch in control room pending resolution of condition." | | | | A fire in the control room could prevent the automatic closing of the | | charging pump suction valves from the volume control tank (VCT) on low level | | transfer to the refueling water storage tank. This would allow the gas used | | in the VCT to expand into the suction of the charging pumps causing gas | | binding. | | | | The licensee notified the NRC Resident Inspector. | | | | HOO Note: Refer to Events #35481 and #35537. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35539 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: INDIAN POINT REGION: 1 |NOTIFICATION DATE: 04/01/1999| | UNIT: [2] [] [] STATE: NY |NOTIFICATION TIME: 17:24[EST]| | RXTYPE: [2] W-4-LP,[3] W-4-LP |EVENT DATE: 04/01/1999| +------------------------------------------------+EVENT TIME: 14:38[EST]| | NRC NOTIFIED BY: MICHELLE SAVINO |LAST UPDATE DATE: 04/01/1999| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |KATHLEEN MODES R1 | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | |NLCO TECH SPEC LCO A/S | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |2 N Y 99 Power Operation |99 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | COURTESY NOTIFICATION ON LOSS OF DEGRADED VOLTAGE INDICATION ON 480 VAC | | VITAL BUS | | | | The field operator discovered 480 Vac VITAL bus '6A' degraded bus voltage | | monitor light was extinguished. After further investigation it was | | determined that the control power fuses were blown on the degraded bus | | voltage monitor. The fuses were replaced and the circuit was restored | | successfully. This report is made at management discretion. Technical | | Specification 3.5.3 which invokes Table 3.5.3 for undervoltage was entered. | | The LCO action statement requires placing the plant in cold shutdown. The | | plant was in the investigation phase and recovered the circuit in question | | so never commenced a plant shutdown. | | | | The licensee notified the NRC Resident Inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021