Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

Event Notification Report for April 2, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           04/01/1999 - 04/02/1999

                              ** EVENT NUMBERS **

35536  35538  35539  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   35536       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  UNIV. OF MINNESOTA, MINNEAPOLIS      |NOTIFICATION DATE: 03/31/1999|
|LICENSEE:  UNIV. OF MINNESOTA, MINNEAPOLIS      |NOTIFICATION TIME: 17:20[EST]|
|    CITY:  MINNEAPOLIS              REGION:  3  |EVENT DATE:        03/31/1999|
|  COUNTY:                            STATE:  MN |EVENT TIME:        14:30[CST]|
|LICENSE#:  22-00187-46           AGREEMENT:  N  |LAST UPDATE DATE:  04/01/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MARK RING            R3      |
|                                                |LARRY CAMPER         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JERRY STAIGER                |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAAA 20.1906(d)           SURFACE CONT/ EXT RAD |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| Tritium contamination was found on the bottom of a package delivered by      |
| FEDEX to the University of Minnesota Duluth campus.                          |
|                                                                              |
| A package containing Phosphorus-33 delivered by FEDEX, (origin Amersham of   |
| Chicago), to the University of Minnesota, Duluth campus was found to have    |
| Tritium contamination only on the bottom of the package.  Swipes of  the     |
| package were taken twice and each time only contamination was found on the   |
| bottom of the package. The contamination level of each swipe was 50,000 DPM. |
| The package was double bagged and the carpeting on which the package was     |
| resting was covered to prevent spread of contamination.  The RSO for the     |
| University of Minnesota Minneapolis campus contacted the Amersham RSO,       |
| located in Chicago, IL.,  and informed him of this incident. The RSO for the |
| University of Minnesota Minneapolis campus said that they were going to take |
| another swipe of the package tomorrow morning (04/01/99) and take a reading  |
| of the swipe to make sure that the contamination of the package is from      |
| Tritium. The University of Minnesota at Duluth only received one package     |
| from FEDEX so the Tritium contamination of the bottom of the package did not |
| come from the carpeting of the floor.                                        |
|                                                                              |
| Contact the HOO for contact numbers.                                         |
|                                                                              |
| * * * UPDATE 1050EST ON 4/1/99 FROM J. STAIGER TO S.SANDIN * * *             |
|                                                                              |
| The licensee is retracting this event after confirming that the              |
| scintillation counter response was due to chemical luminescence rather than  |
| tritium contamination.  The licensee discussed this with R3(Jones) and       |
| notified the Amersham RSO as well as FEDEX.  Notified R3DO (Ring).           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35538       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NORTH ANNA               REGION:  2  |NOTIFICATION DATE: 04/01/1999|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 16:01[EST]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        04/01/1999|
+------------------------------------------------+EVENT TIME:        15:50[EST]|
| NRC NOTIFIED BY:  K. D. DEVOR                  |LAST UPDATE DATE:  04/01/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHARLES OGLE         R2      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POSSIBLE GAS BINDING OF CHARGING PUMPS DURING CONTROL ROOM FIRE              |
|                                                                              |
| "Engineering has identified the possibility of equipment failure during an   |
| Appendix 'R' control room fire leading to gas binding of all charging pumps. |
| This condition places [both] units outside of  Appendix 'R' design basis.    |
|                                                                              |
| "Compensatory actions:  1) O-FCA-1 [procedure is] being changed to address   |
| this condition (Fire Contingency Action, Control Room Fire); 2) establishing |
| continuous fire watch in control room pending resolution of condition."      |
|                                                                              |
| A fire in the control room could prevent the automatic closing of the        |
| charging pump suction valves from the volume control tank (VCT) on low level |
| transfer to the refueling water storage tank.  This would allow the gas used |
| in the VCT to expand into the suction of the charging pumps causing gas      |
| binding.                                                                     |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| HOO Note:  Refer to  Events  #35481 and #35537.                              |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35539       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 04/01/1999|
|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 17:24[EST]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        04/01/1999|
+------------------------------------------------+EVENT TIME:        14:38[EST]|
| NRC NOTIFIED BY:  MICHELLE SAVINO              |LAST UPDATE DATE:  04/01/1999|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |KATHLEEN MODES       R1      |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|NLCO                     TECH SPEC LCO A/S      |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       99       Power Operation  |99       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| COURTESY NOTIFICATION ON LOSS OF DEGRADED VOLTAGE INDICATION ON 480 VAC      |
| VITAL BUS                                                                    |
|                                                                              |
| The field operator discovered 480 Vac VITAL bus '6A' degraded bus voltage    |
| monitor light was extinguished. After further investigation it was           |
| determined that the control power fuses were blown on the degraded bus       |
| voltage monitor.  The fuses were replaced and the circuit was restored       |
| successfully.  This report is made at management discretion.   Technical     |
| Specification 3.5.3 which invokes Table 3.5.3 for undervoltage was entered.  |
| The LCO action statement requires placing the plant in cold shutdown.  The   |
| plant was in the investigation phase and recovered the circuit in question   |
| so never commenced a plant shutdown.                                         |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021