Event Notification Report for March 24, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/23/1999 - 03/24/1999

                              ** EVENT NUMBERS **

35500  35501  35502  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35500       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GRAND GULF               REGION:  4  |NOTIFICATION DATE: 03/22/1999|
|    UNIT:  [1] [] []                 STATE:  MS |NOTIFICATION TIME: 19:16[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        03/22/1999|
+------------------------------------------------+EVENT TIME:        18:00[CST]|
| NRC NOTIFIED BY:  MARTY McADORY                |LAST UPDATE DATE:  03/23/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHARLES CAIN         R4      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - EMERGENCY OPERATIONS FACILITY INOPERABLE DUE TO TWO INOPERABLE AIR         |
| COMPRESSORS -                                                                |
|                                                                              |
| THE LICENSEE DECLARED BOTH AIR COMPRESSORS AT THE ENTERGY SERVICES CENTER    |
| INOPERABLE WHEN THEY FAILED TO START DURING A TEST.  THESE COMPRESSORS       |
| SUPPLY AIR NECESSARY TO ISOLATE THE EMERGENCY OPERATIONS FACILITY (EOF),     |
| OPERATE THE HVAC SYSTEMS, AND START THE BACKUP GENERATOR.  ONE UNIT HAS A    |
| FAULTY COMPRESSOR AND THE OTHER HAS A FAULTY CIRCUIT BREAKER.                |
|                                                                              |
| THE LICENSEE PLANS TO SWAP CIRCUIT BREAKERS AND RESTORE ONE UNIT TO OPERABLE |
| STATUS.  THE LICENSEE DECLARED THE EOF INOPERABLE.                           |
|                                                                              |
| THE LICENSEE HAS NOTIFIED STATE AND LOCAL OFFICIALS, LICENSEE EMERGENCY      |
| RESPONSE PERSONNEL, AND THE NRC RESIDENT INSPECTOR THAT THE EOF IS           |
| INOPERABLE AND TO RESPOND TO THE BACKUP EOF LOCATED AT THE BAXTER WILSON     |
| POWER STATION IN VICKSBURG, MS, APPROXIMATELY 30 MILES FROM THE SITE, IF THE |
| EOF IS REQUIRED TO BE STAFFED.                                               |
|                                                                              |
| * * * UPDATE AT 1721 ON 03/23/99 BY ERNEST MATHES TO JOLLIFFE * * *          |
|                                                                              |
| AT 1620 CDT ON 03/23/99, THE LICENSEE REPAIRED BOTH EOF AIR COMPRESSORS,     |
| DECLARED THEM OPERABLE, AND DECLARED THE EOF OPERABLE.                       |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
|                                                                              |
| THE NRC OPERATIONS OFFICER NOTIFIED THE R4DO CHUCK CAIN.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   35501       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FLORIDA BUREAU OF RADIATION CONTROL  |NOTIFICATION DATE: 03/23/1999|
|LICENSEE:  J & M TESTING, INC                   |NOTIFICATION TIME: 13:01[EST]|
|    CITY:  CHIPLEY                  REGION:  2  |EVENT DATE:        03/10/1999|
|  COUNTY:                            STATE:  FL |EVENT TIME:        14:15[EST]|
|LICENSE#:  1763-1                AGREEMENT:  Y  |LAST UPDATE DATE:  03/23/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MARK LESSER          R2      |
|                                                |                             |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHARLES ADAMS                |                             |
|  HQ OPS OFFICER:  DICK JOLLIFFE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - AGREEMENT STATE REPORT - TWO LOST PORTABLE NUCLEAR SOIL MOISTURE DENSITY   |
| GAUGES -                                                                     |
|                                                                              |
| At 1415 on 03/10/99, during a Florida state inspection of J & M Testing,     |
| Inc., two portable nuclear soil moisture density gauges were determined to   |
| be missing.  These are old gauges that were not being used and were last     |
| seen during an inventory taken on 12/28/98.   The Chipley, FL police         |
| department has been notified.                                                |
|                                                                              |
| Specifications of the gauges are as follows:                                 |
| 1.  Manufacturer: CPN, Model: BRC (1977); Serial No C7304NE147; Isotopes: 8  |
| mCi Cs-137; 50 mCi Am-241/Be                                                 |
| 2.  Manufacturer: CPN, Model: BRC (1974); Serial No C7404NE50;   Isotopes: 8 |
| mCi Cs-137; 50 mCi Am-241/Be                                                 |
|                                                                              |
| Charles Adams, FL Bureau of Radiation Control, notified NRC Region 2 (FL     |
| Radiological Incident No FL99-07).                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35502       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 03/23/1999|
|    UNIT:  [] [2] []                 STATE:  WI |NOTIFICATION TIME: 16:48[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        03/23/1999|
+------------------------------------------------+EVENT TIME:        15:07[CST]|
| NRC NOTIFIED BY:  RICK ROBBINS                 |LAST UPDATE DATE:  03/23/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |PATRICK HILAND       R3      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - S/G PRESSURE TRANSMITTER CABLE NOT WRAPPED WITH FIRE WRAP IN A FIRE ZONE   |
| -                                                                            |
|                                                                              |
| AT 1507 CDT ON 03/23/99, DURING A 10CFR50, APPENDIX R REBASELINE REVIEW, THE |
| LICENSEE DISCOVERED THAT CABLE #ZP2I483F FOR RED CHANNEL STEAM GENERATOR 'B' |
| PRESSURE TRANSMITTER #2PT-00483 ROUTED THROUGH A FIRE ZONE IS NOT PROPERLY   |
| WRAPPED WITH FIRE WRAP.   THUS, THE RED CHANNEL STEAM GENERATOR 'B' PRESSURE |
| TRANSMITTER WOULD NOT BE AVAILABLE, AS EXPECTED, DURING A FIRE IN THIS       |
| ZONE.                                                                        |
|                                                                              |
| A FOUR HOUR ROVING FIRE WATCH ALREADY EXISTS FOR THIS FIRE ZONE FOR OTHER    |
| REASONS AND WILL REMAIN IN EFFECT UNTIL THIS PROBLEM IS CORRECTED.           |
|                                                                              |
| THIS PROBLEM IS APPLICABLE TO UNIT 2 ONLY AND HAS NO EFFECT ON UNIT 1.       |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+