Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for March 24, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/23/1999 - 03/24/1999

                              ** EVENT NUMBERS **

35500  35501  35502  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35500       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GRAND GULF               REGION:  4  |NOTIFICATION DATE: 03/22/1999|
|    UNIT:  [1] [] []                 STATE:  MS |NOTIFICATION TIME: 19:16[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        03/22/1999|
+------------------------------------------------+EVENT TIME:        18:00[CST]|
| NRC NOTIFIED BY:  MARTY McADORY                |LAST UPDATE DATE:  03/23/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CHARLES CAIN         R4      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - EMERGENCY OPERATIONS FACILITY INOPERABLE DUE TO TWO INOPERABLE AIR         |
| COMPRESSORS -                                                                |
|                                                                              |
| THE LICENSEE DECLARED BOTH AIR COMPRESSORS AT THE ENTERGY SERVICES CENTER    |
| INOPERABLE WHEN THEY FAILED TO START DURING A TEST.  THESE COMPRESSORS       |
| SUPPLY AIR NECESSARY TO ISOLATE THE EMERGENCY OPERATIONS FACILITY (EOF),     |
| OPERATE THE HVAC SYSTEMS, AND START THE BACKUP GENERATOR.  ONE UNIT HAS A    |
| FAULTY COMPRESSOR AND THE OTHER HAS A FAULTY CIRCUIT BREAKER.                |
|                                                                              |
| THE LICENSEE PLANS TO SWAP CIRCUIT BREAKERS AND RESTORE ONE UNIT TO OPERABLE |
| STATUS.  THE LICENSEE DECLARED THE EOF INOPERABLE.                           |
|                                                                              |
| THE LICENSEE HAS NOTIFIED STATE AND LOCAL OFFICIALS, LICENSEE EMERGENCY      |
| RESPONSE PERSONNEL, AND THE NRC RESIDENT INSPECTOR THAT THE EOF IS           |
| INOPERABLE AND TO RESPOND TO THE BACKUP EOF LOCATED AT THE BAXTER WILSON     |
| POWER STATION IN VICKSBURG, MS, APPROXIMATELY 30 MILES FROM THE SITE, IF THE |
| EOF IS REQUIRED TO BE STAFFED.                                               |
|                                                                              |
| * * * UPDATE AT 1721 ON 03/23/99 BY ERNEST MATHES TO JOLLIFFE * * *          |
|                                                                              |
| AT 1620 CDT ON 03/23/99, THE LICENSEE REPAIRED BOTH EOF AIR COMPRESSORS,     |
| DECLARED THEM OPERABLE, AND DECLARED THE EOF OPERABLE.                       |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
|                                                                              |
| THE NRC OPERATIONS OFFICER NOTIFIED THE R4DO CHUCK CAIN.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   35501       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  FLORIDA BUREAU OF RADIATION CONTROL  |NOTIFICATION DATE: 03/23/1999|
|LICENSEE:  J & M TESTING, INC                   |NOTIFICATION TIME: 13:01[EST]|
|    CITY:  CHIPLEY                  REGION:  2  |EVENT DATE:        03/10/1999|
|  COUNTY:                            STATE:  FL |EVENT TIME:        14:15[EST]|
|LICENSE#:  1763-1                AGREEMENT:  Y  |LAST UPDATE DATE:  03/23/1999|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MARK LESSER          R2      |
|                                                |                             |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHARLES ADAMS                |                             |
|  HQ OPS OFFICER:  DICK JOLLIFFE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - AGREEMENT STATE REPORT - TWO LOST PORTABLE NUCLEAR SOIL MOISTURE DENSITY   |
| GAUGES -                                                                     |
|                                                                              |
| At 1415 on 03/10/99, during a Florida state inspection of J & M Testing,     |
| Inc., two portable nuclear soil moisture density gauges were determined to   |
| be missing.  These are old gauges that were not being used and were last     |
| seen during an inventory taken on 12/28/98.   The Chipley, FL police         |
| department has been notified.                                                |
|                                                                              |
| Specifications of the gauges are as follows:                                 |
| 1.  Manufacturer: CPN, Model: BRC (1977); Serial No C7304NE147; Isotopes: 8  |
| mCi Cs-137; 50 mCi Am-241/Be                                                 |
| 2.  Manufacturer: CPN, Model: BRC (1974); Serial No C7404NE50;   Isotopes: 8 |
| mCi Cs-137; 50 mCi Am-241/Be                                                 |
|                                                                              |
| Charles Adams, FL Bureau of Radiation Control, notified NRC Region 2 (FL     |
| Radiological Incident No FL99-07).                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35502       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 03/23/1999|
|    UNIT:  [] [2] []                 STATE:  WI |NOTIFICATION TIME: 16:48[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        03/23/1999|
+------------------------------------------------+EVENT TIME:        15:07[CST]|
| NRC NOTIFIED BY:  RICK ROBBINS                 |LAST UPDATE DATE:  03/23/1999|
|  HQ OPS OFFICER:  DICK JOLLIFFE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |PATRICK HILAND       R3      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| - S/G PRESSURE TRANSMITTER CABLE NOT WRAPPED WITH FIRE WRAP IN A FIRE ZONE   |
| -                                                                            |
|                                                                              |
| AT 1507 CDT ON 03/23/99, DURING A 10CFR50, APPENDIX R REBASELINE REVIEW, THE |
| LICENSEE DISCOVERED THAT CABLE #ZP2I483F FOR RED CHANNEL STEAM GENERATOR 'B' |
| PRESSURE TRANSMITTER #2PT-00483 ROUTED THROUGH A FIRE ZONE IS NOT PROPERLY   |
| WRAPPED WITH FIRE WRAP.   THUS, THE RED CHANNEL STEAM GENERATOR 'B' PRESSURE |
| TRANSMITTER WOULD NOT BE AVAILABLE, AS EXPECTED, DURING A FIRE IN THIS       |
| ZONE.                                                                        |
|                                                                              |
| A FOUR HOUR ROVING FIRE WATCH ALREADY EXISTS FOR THIS FIRE ZONE FOR OTHER    |
| REASONS AND WILL REMAIN IN EFFECT UNTIL THIS PROBLEM IS CORRECTED.           |
|                                                                              |
| THIS PROBLEM IS APPLICABLE TO UNIT 2 ONLY AND HAS NO EFFECT ON UNIT 1.       |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+