Event Notification Report for March 23, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 03/22/1999 - 03/23/1999 ** EVENT NUMBERS ** 35477 35497 35498 35499 35500 +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 35477 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: FLORIDA BUREAU OF RADIATION CONTROL |NOTIFICATION DATE: 03/17/1999| |LICENSEE: NDT & INSPECTIONS |NOTIFICATION TIME: 07:39[EST]| | CITY: PEMBROKE PINES REGION: 2 |EVENT DATE: 03/17/1999| | COUNTY: BROWARD STATE: FL |EVENT TIME: 05:12[EST]| |LICENSE#: 2941-1 AGREEMENT: Y |LAST UPDATE DATE: 03/22/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |KERRY LANDIS R2 | | |DON COOL EO NMSS | +------------------------------------------------+ROSEMARY HOGAN IRO | | NRC NOTIFIED BY: EAKINS | | | HQ OPS OFFICER: CHAUNCEY GOULD | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE FLORIDA BUREAU OF RADIATION CONTROL REPORTED A STOLEN RADIOGRAPHY | | CAMERA. | | | | THE CAMERA (AEA TECHNOLOGY MODEL 66B) IS THE PROPERTY OF NDT & INSPECTIONS | | OF PEMBROKE PINES, FL. IT CONTAINS 88.3 CURIES OF IRIDIUM-192. IT WAS | | STOLEN FROM A TRAILER AT THE RADIOGRAPHER'S HOUSE IN PEMBROKE PINES, FL | | BETWEEN 0400 AND 0440 ON 03/17/99. THE SOURCE SERIAL NUMBER IS C9062. THE | | INDIVIDUALS THAT STOLE THE DEVICE ALSO HAVE THE KEYS FOR THE CAMERA. THERE | | WILL BE A PRESS RELEASE BY BROWARD COUNTY. | | | | THE FLORIDA REPORT NUMBER IS FL99-039. | | | | CONTACT THE HOO FOR STATE TELEPHONE NUMBER. | | | | * * * UPDATE AT 1230 ON 03/17/99 BY STRANSKY * * * | | | | THE NRC ENTERED THE MONITORING PHASE OF NORMAL RESPONSE MODE AT 1230 ON | | 03/17/99 AS A RESULT OF THIS EVENT. THE NRC OPERATIONS OFFICER NOTIFIED IRO | | (CONGEL), CHAIRMAN'S OFFICE (WEBER), EDO (TSCHILTZ), OPA (LANDAU), AND | | OTHER FEDERAL AGENCIES (VIA FAX AND PHONE). | | | | * * * UPDATE AT 1205 ON 03/22/99 BY JOLLIFFE * * * | | | | AT 1205 ON 03/22/99, THE NRC SECURED FROM THE MONITORING PHASE OF NORMAL | | RESPONSE MODE. THE CAMERA HAS NOT BEEN LOCATED. THE NRC OPERATIONS OFFICER | | NOTIFIED THE FOLLOWING: CHAIRMAN (MIKE WEBER), EDO (GLEN TRACY), NMSS EO | | (DON COOL), R2DO (KERRY LANDIS), IRO (CHARLIE MILLER/ROSEMARY HOGAN), OPA | | (VIC DRICKS), FBI (JIM KUNKEL), EPA (NRC) (MATT ROBERTSON), DOE (MIKE | | WYATT), USDA (LORI THOMAS), HHS (MARK KEIM), AND FEMA (PAUL WRIGHT). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35497 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: CALVERT CLIFFS REGION: 1 |NOTIFICATION DATE: 03/22/1999| | UNIT: [] [2] [] STATE: MD |NOTIFICATION TIME: 18:15[EST]| | RXTYPE: [1] CE,[2] CE |EVENT DATE: 03/22/1999| +------------------------------------------------+EVENT TIME: 16:58[EST]| | NRC NOTIFIED BY: BOB PACE |LAST UPDATE DATE: 03/22/1999| | HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JACK MCFADDEN R1 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N N 0 Refueling |0 Refueling | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - MARYLAND DEPARTMENT OF THE ENVIRONMENT NOTIFIED OF A 5 GALLON OIL SPILL | | ONSITE - | | | | AT 1658 ON 03/22/99, THE LICENSEE NOTIFIED THE MARYLAND DEPARTMENT OF THE | | ENVIRONMENT THAT THE LICENSEE HAD SPILLED APPROXIMATELY FIVE GALLONS OF | | DIESEL FUEL OIL ONTO THE GROUND WHILE FILLING A FUEL TANK ADJACENT TO THE | | UNIT 2 MAIN TRANSFORMER OUTSIDE THE UNIT 2 CONTAINMENT BUTLER BUILDING. THE | | SPILL DID NOT REACH ANY STORM DRAINS OR THE BAY. THE LICENSEE PLANS TO DIG | | UP THE OIL SOAKED SOIL AND DISPOSE OF IT PROPERLY. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 35498 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ALABAMA RADIATION CONTROL |NOTIFICATION DATE: 03/22/1999| |LICENSEE: UNIVERSITY of AL at BIRMINGHAM |NOTIFICATION TIME: 18:57[EST]| | CITY: BIRMINGHAM REGION: 2 |EVENT DATE: 03/18/1999| | COUNTY: STATE: AL |EVENT TIME: 15:00[CST]| |LICENSE#: 266 AGREEMENT: Y |LAST UPDATE DATE: 03/22/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |KERRY LANDIS R2 | | |JOSIE PICCONE, EO NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: J. McNees/D. Turberville | | | HQ OPS OFFICER: DICK JOLLIFFE | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT (ALABAMA INCIDENT #99-6) - LOST I-125 MEDICAL THERAPY | | SEEDS | | | | In the late afternoon of March 19, 1999, the State of Alabama was contacted | | by the University of Alabama at Birmingham (Alabama Radioactive Material | | License No. 266) concerning an incident involving lost or stolen Iodine-125 | | medical therapy seeds. The seeds, used for the treatment of prostate | | cancer, were delivered to the licensee's permittee (the medical user) by an | | employee of the licensee's Hazardous Material Facility on the afternoon of | | March 18, 1999. Upon delivery, the individual placed the package on the top | | of a trash can and then went to check on a patient. Upon his return, the | | package was missing. The package contained 107 seeds of I-125 with a total | | activity of 37.5 millicuries in a lead pig. The licensee continues the | | process of interviewing housekeeping personnel and surveying trash dumpsters | | to locate the package. As of the close of business on March 22, 1999, the | | radioactive seeds had not been located despite extensive efforts by the | | licensee. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 35499 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ALABAMA RADIATION CONTROL |NOTIFICATION DATE: 03/22/1999| |LICENSEE: BHATE ENGINEERING CORP |NOTIFICATION TIME: 19:05[EST]| | CITY: BIRMINGHAM REGION: 2 |EVENT DATE: 03/17/1999| | COUNTY: STATE: AL |EVENT TIME: 15:00[CST]| |LICENSE#: 655 AGREEMENT: Y |LAST UPDATE DATE: 03/22/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |KERRY LANDIS R2 | | |JOSIE PICCONE, EO NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: J. McNees/D. Turberville | | | HQ OPS OFFICER: DICK JOLLIFFE | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE EVENT (ALABAMA INCIDENT #99-5) - Damaged Troxler Moisture | | Density Gauge | | | | In the morning of March 18, 1999, the State of Alabama was contacted by | | William B. Bass, a radiological consultant on behalf of Bhate Engineering | | Corporation of Birmingham (Alabama Radioactive Material License No. 655) | | concerning an incident involving a damaged Troxler Moisture Density Gauge. | | Mr. Bass reported that at approximately 1500 CST on March 17, 1999, the | | radioactive device was accidentally driven over by a John Deere 770B-H Motor | | Grader. The Troxler gauge was in the closed shielded position when the | | accident occurred. The impact bent the source rod and "crushed" the shield | | around the source. Mr. Bass reported that he checked for contamination and | | finding none, secured the rod with duct tape to prevent any movement and | | placed the damaged device in the case and secured it in place with duct | | tape. The area was surveyed and determined to be contamination free and a | | wipe test made along the seams of the damaged device. Radiation exposure | | levels adjacent to the device were 2.5 mR/hr at six inches from the surface | | which is typical for an undamaged Troxler device. The licensee intends to | | ship the damaged device to the manufacturer. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35500 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: GRAND GULF REGION: 4 |NOTIFICATION DATE: 03/22/1999| | UNIT: [1] [] [] STATE: MS |NOTIFICATION TIME: 19:16[EST]| | RXTYPE: [1] GE-6 |EVENT DATE: 03/22/1999| +------------------------------------------------+EVENT TIME: 18:00[CST]| | NRC NOTIFIED BY: MARTY McADORY |LAST UPDATE DATE: 03/22/1999| | HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |CHARLES CAIN R4 | |10 CFR SECTION: | | |AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | - EMERGENCY OPERATIONS FACILITY INOPERABLE DUE TO TWO INOPERABLE AIR | | COMPRESSORS - | | | | THE LICENSEE DECLARED BOTH AIR COMPRESSORS AT THE ENTERGY SERVICES CENTER | | INOPERABLE WHEN THEY FAILED TO START DURING A TEST. THESE COMPRESSORS | | SUPPLY AIR NECESSARY TO ISOLATE THE EMERGENCY OPERATIONS FACILITY (EOF), | | OPERATE THE HVAC SYSTEMS, AND START THE BACKUP GENERATOR. ONE UNIT HAS A | | FAULTY COMPRESSOR AND THE OTHER HAS A FAULTY CIRCUIT BREAKER. | | | | THE LICENSEE PLANS TO SWAP CIRCUIT BREAKERS AND RESTORE ONE UNIT TO OPERABLE | | STATUS. THE LICENSEE DECLARED THE EOF INOPERABLE. | | | | THIS CONDITION IS A VIOLATION OF THE FACILITY OPERATING LICENSE, ATTACHMENT | | I(e)(3). | | | | THE LICENSEE HAS NOTIFIED STATE AND LOCAL OFFICIALS, LICENSEE EMERGENCY | | RESPONSE PERSONNEL, AND THE NRC RESIDENT INSPECTOR THAT THE EOF IS | | INOPERABLE AND TO RESPOND TO THE BACKUP EOF LOCATED AT THE BAXTER WILSON | | POWER STATION IN VICKSBURG, MS, APPROXIMATELY 30 MILES FROM THE SITE, IF THE | | EOF IS REQUIRED TO BE STAFFED. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021