The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for February 17, 1999
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
02/16/1999 - 02/17/1999
** EVENT NUMBERS **
35309 35371 35372 35373 35374 35375
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35309 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 01/22/1999|
| UNIT: [] [2] [] STATE: NY |NOTIFICATION TIME: 19:40[EST]|
| RXTYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 01/20/1999|
+------------------------------------------------+EVENT TIME: 17:30[EST]|
| NRC NOTIFIED BY: ROY GREEN |LAST UPDATE DATE: 02/16/1999|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |FRANK COSTELLO R1 |
|10 CFR SECTION: | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
|NLCO TECH SPEC LCO A/S | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LATE NOTIFICATION ON REACTOR CORE ISOLATION COOLING (RCIC) BEING DECLARED |
| INOPERABLE ON 01/20/99 |
| |
| On 01/20/99 at 1730 EST, RCIC became inoperable as a result of two |
| inoperable primary containment isolation valves being closed to satisfy |
| Technical Specification 3.6.3. RCIC was declared inoperable per Technical |
| Specification 3.7.4 (14 days to restore to operable status). Initial |
| assessment conclude that an immediate report was not required. However, |
| upon additional review, it has been determined that a 4-hour report is |
| required in accordance with 10 CFR 50. 72(b)(2)(iii)(D). RCIC was restored |
| to operable status on 01/22/99 at 1142 EST. The technical specifications |
| mentioned above were exited at the time. During the time period RCIC was |
| out of service, all emergency core cooling systems were fully operable. |
| |
| The NRC resident inspector was notified of this event by the licensee. |
| |
| ******************** UPDATE AT 1631 ON 02/16/99 FROM ROY GREEN TO TROCINE |
| ******************** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "... RCIC was declared inoperable when it was believed [that] the starter |
| coils for two RCIC containment isolation valves (CIVs) would not function |
| properly in a degraded voltage situation, and the CIVs were closed to comply |
| with technical specifications.. |
| |
| "Subsequent review has determined that since the event or condition was |
| associated with the containment isolation function only and [since] the |
| reporting criteria is concerned with RCIC injection, the event is not |
| reportable. The operator actions to close the CIVs in accordance with |
| technical specifications [do] not constitute an event or condition as |
| discussed in the NUREG guidance. Therefore, notification of the event is |
| retracted. Additionally, evaluation and testing has concluded that the |
| starter coils in question would have functioned under all design |
| conditions. |
| |
| The licensee notified the NRC resident inspector. The NRC operations |
| officer notified the R1DO (Trapp). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35371 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA REGION: 2 |NOTIFICATION DATE: 02/15/1999|
| UNIT: [1] [] [] STATE: SC |NOTIFICATION TIME: 22:33[EST]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 02/15/1999|
+------------------------------------------------+EVENT TIME: 21:45[EST]|
| NRC NOTIFIED BY: GARY CLEMENTS |LAST UPDATE DATE: 02/16/1999|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |THOMAS DECKER R2 |
|10 CFR SECTION: | |
|AUNA 50.72(b)(1)(ii)(A) UNANALYZED COND OP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY THAT UNIT 1 FUELING WATER STORAGE TANK (FWST) CHANNEL 3 WAS NOT |
| PLACED IN BYPASS WITHIN 6 HOURS OF BECOMING INOPERABLE |
| |
| FWST Channel 3 was tripped shortly after 0800 today to facilitate a |
| modification to change out a transmitter. With this channel removed from |
| service, plant technical specifications require the licensee to place the |
| channel in bypass within 6 hours. At 2145, it was discovered that the |
| channel had not been placed in bypass within 6 hours of becoming inoperable, |
| and the unit entered Technical Specification 3.0.3. The channel was |
| successfully placed in bypass within 2 minutes, and Technical Specification |
| 3.0.3 was exited at 2147. |
| |
| The licensee plans to notify the NRC resident inspector. |
| |
| [HOO NOTE: This event report is being reissued to correct the site name.] |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35372 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK REGION: 3 |NOTIFICATION DATE: 02/16/1999|
| UNIT: [1] [2] [] STATE: MI |NOTIFICATION TIME: 18:08[EST]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 02/16/1999|
+------------------------------------------------+EVENT TIME: 16:35[EST]|
| NRC NOTIFIED BY: CHUCK SMITH |LAST UPDATE DATE: 02/16/1999|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MIKE JORDAN R3 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(ii) RPS ACTUATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 M/R N 0 Hot Standby |0 Hot Standby |
|2 M/R N 0 Hot Standby |0 Hot Standby |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HISTORICAL MANUAL REACTOR TRIPS FROM MODE 3 (HOT STANDBY) DUE TO ROD GROUPS |
| MOVING OUT OF SEQUENCE DURING ROD DROP TESTING |
| |
| During a review of industry Licensee Event Reports, the licensee determined |
| that two historical manual reactor trips were reportable. This |
| determination was made at 1635 on 02/16/99. |
| |
| The events occurred on 10/13/90 for Unit 2 (Cycle 8) and 05/12/94 for Unit 1 |
| (Cycle 14) while both units were in Mode 3 (Hot Standby) in preparation for |
| exit refueling outages. On both occasions, the licensee was performing rod |
| drop testing. When operators began to pull out one of the control banks on |
| Unit 2 and one of the shutdown banks on Unit 1, one group moved prior to the |
| other (out of sequence). To alleviate this problem and to prevent the need |
| to realign individual rods, the licensee manually opened the reactor trip |
| breakers on both occasions. The historical engineering data did not |
| indicate any significant abnormalities. |
| |
| Both units are currently in Mode 5 (Cold Shutdown). |
| |
| The licensee notified the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35373 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM REGION: 1 |NOTIFICATION DATE: 02/17/1999|
| UNIT: [] [2] [] STATE: NJ |NOTIFICATION TIME: 02:16[EST]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 02/17/1999|
+------------------------------------------------+EVENT TIME: 02:02[EST]|
| NRC NOTIFIED BY: STEVE SAUER |LAST UPDATE DATE: 02/17/1999|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JIM TRAPP R1 |
|10 CFR SECTION: | |
|ASHU 50.72(b)(1)(i)(A) PLANT S/D REQD BY TS | |
|NLCO TECH SPEC LCO A/S | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |98 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - TECH SPEC REQUIRED PLANT SHUTDOWN DUE TO A 28 VOLT DC BATTERY CELL TESTING |
| LOW - |
| |
| AT 0202 ON 02/17/99, DURING THE PERFORMANCE OF A QUARTERLY SURVEILLANCE |
| TEST, THE VOLTAGE OF ONE OF THE 28 VOLT DC BATTERY CELLS TESTED AT 2.11 VDC. |
| THE TECH SPEC MINIMUM LIMIT IS 2.13 VDC. TECH SPEC LCO A/S 3.8.2.5 REQUIRES |
| THE LICENSEE TO REPLACE THE AFFECTED CELL IN TWO HOURS OR PLACE UNIT 2 IN |
| HOT STANDBY MODE WITHIN SIX HOURS. THE LICENSEE PLANS TO REPLACE THE |
| AFFECTED CELL WITHIN TWO HOURS. |
| |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. |
| |
| * * * UPDATE AT 0354 ON 02/17/99 BY STEVE SAUER TO JOLLIFFE * * * |
| |
| AT 0351 ON 02/17/99, THE LICENSEE REPLACED THE AFFECTED BATTERY CELL AND |
| EXITED TECH SPEC LCO A/S 3.8.2.5. |
| |
| THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR. |
| |
| THE NRC OPERATIONS OFFICER NOTIFIED THE R1DO JIM TRAPP. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35374 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK REGION: 1 |NOTIFICATION DATE: 02/17/1999|
| UNIT: [1] [2] [] STATE: PA |NOTIFICATION TIME: 03:50[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 02/17/1999|
+------------------------------------------------+EVENT TIME: 02:50[EST]|
| NRC NOTIFIED BY: CARL RICH |LAST UPDATE DATE: 02/17/1999|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JIM TRAPP R1 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - PLANT SECURITY REPORT - |
| |
| DISCOVERY OF COMPROMISE OF PLANT SECURITY DOCUMENT. COMPENSATORY MEASURES |
| IMMEDIATELY TAKEN UPON DISCOVERY. |
| |
| THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR. |
| |
| REFER TO THE HOO LOG FOR ADDITIONAL DETAILS. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35375 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: QUAD CITIES REGION: 3 |NOTIFICATION DATE: 02/17/1999|
| UNIT: [] [2] [] STATE: IL |NOTIFICATION TIME: 05:16[EST]|
| RXTYPE: [1] GE-3,[2] GE-3 |EVENT DATE: 02/17/1999|
+------------------------------------------------+EVENT TIME: 00:20[CST]|
| NRC NOTIFIED BY: DARYL NOHR |LAST UPDATE DATE: 02/17/1999|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MIKE JORDAN R3 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - UNIT 2 RECEIVED ESF ACTUATIONS DUE TO A FAILED VOLTAGE REGULATOR - |
| |
| AT 0020 CST ON 02/17/99, UNIT 2 (100% POWER) UNEXPECTEDLY RECEIVED THE |
| FOLLOWING ESF ACTUATIONS: HALF SCRAM SIGNAL, HALF PRIMARY CONTAINMENT |
| ISOLATION SYSTEM (PCIS) GROUP 1 ISOLATION SIGNAL (MAIN STEAM LINE VALVES), |
| HALF PCIS GROUP 2 ISOLATION SIGNAL (VENT & SAMPLE VALVES INSIDE THE DRYWELL) |
| AND REACTOR WATER CLEANUP ISOLATION SIGNAL. AS PART OF THE PARTIAL PCIS |
| GROUP 2 ESF ACTUATION, SEVERAL PRIMARY CONTAINMENT ISOLATION VALVES CLOSED. |
| |
| |
| AT THE TIME OF THE ESF ACTUATION, THE #2A REACTOR PROTECTION SYSTEM (RPS) |
| WAS BEING SUPPLIED FROM ITS RESERVE FEED AND THE LICENSEE DETERMINED IT TO |
| BE TRIPPED DUE TO A FAILED VOLTAGE REGULATOR. THE LICENSEE REENERGIZED THE |
| #2A RPS FROM ITS NORMAL FEED AND RESTORED THE PLANT LINEUP TO NORMAL EXCEPT |
| THE #2A MAIN STEAM LINE RADIATION MONITOR DOWNSCALE WOULD NOT RESET. THE |
| LICENSEE INSERTED A HALF SCRAM SIGNAL AND A HALF PCIS GROUP 1 ISOLATION |
| SIGNAL IN ACCORDANCE WITH TECH SPEC REQUIREMENTS WHILE REPAIRS ARE IN |
| PROGRESS. |
| |
| THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021