Event Notification Report for February 3, 1999
                    U.S. Nuclear Regulatory Commission
                              Operations Center
                              Event Reports For
                           02/02/1999 - 02/03/1999
                              ** EVENT NUMBERS **
35295  35339  
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35295       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 01/21/1999|
|    UNIT:  [1] [] []                 STATE:  WI |NOTIFICATION TIME: 16:59[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        01/21/1999|
+------------------------------------------------+EVENT TIME:        15:00[CST]|
| NRC NOTIFIED BY:  RICK ROBBINS                 |LAST UPDATE DATE:  02/02/1999|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROGER LANKSBURY      R3      |
|10 CFR SECTION:                                 |                             |
|AOUT 50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| Material for deionized water supply valve changed                            |
|                                                                              |
| During storeroom valve stock review, the licensee discovered that valve      |
| materials for a deionized water supply line containment isolation valve had  |
| changed.  Specifically, the diaphragm material had changed.  The design      |
| value for the original material was 200� F at 200 psi.  The new valve was    |
| rated at 150�  F at 300 psi.  This valve inside containment and another      |
| valve outside containment are normally closed during operation.  Further     |
| evaluations are underway.                                                    |
|                                                                              |
| Containment integrity has been verified by ensuring the valve outside        |
| containment is locked shut.                                                  |
|                                                                              |
| The NRC resident inspector will be notified of this event by the licensee.   |
|                                                                              |
| * * * RETRACTED ON 2/2/99 AT 1122 EST BY MIKE MEYER TO FANGIE JONES * * *    |
|                                                                              |
| After further investigation, the licensee determined that valve 1DI-11 and   |
| the outside containment isolation valve (1DI-19) are locked closed during    |
| times that containment integrity is required.  Therefore, even if the        |
| improper ratings of the valve would have resulted in the valve failing       |
| during a design bases accident, containment integrity would have been        |
| maintained by the normally locked closed valve outside containment.          |
|                                                                              |
| Therefore, this condition does not result in a condition of the plant being  |
| outside its design basis and this event notification is retracted.           |
|                                                                              |
| The licensee intends to notify the NRC Resident Inspector.  The NRC          |
| Operations Officer notified the R3DO (Thomas Kozak).                         |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   35339       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  UNION CAMP CORP                      |NOTIFICATION DATE: 02/02/1999|
|LICENSEE:  UNION CAMP CORP                      |NOTIFICATION TIME: 15:34[EST]|
|    CITY:  FRANKLIN                 REGION:  2  |EVENT DATE:        02/01/1999|
|  COUNTY:                            STATE:  VA |EVENT TIME:             [EST]|
|LICENSE#:  45-11414-01           AGREEMENT:  N  |LAST UPDATE DATE:  02/02/1999|
|  DOCKET:  030-0659                             |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |PAUL FREDRICKSON     R2      |
|                                                |FRED COMBS           EO      |
+------------------------------------------------+STUART RUBIN         IRO     |
| NRC NOTIFIED BY:  HUGH RALSTON                 |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LICENSEE REPORTED A LOST AMERICIUM-241 SOURCE DURING SHIPMENT.               |
|                                                                              |
| "THE SOURCE MATERIAL LOST IN SHIPMENT IS AN AMERICIUM-241 80mCi SEALED       |
| SOURCE CERAMIC ENCAPSULATED BY WELDED STAINLESS STEEL.  THE SOURCE SERIAL    |
| NUMBER IS 8462LX MOUNTED IN DEVICE NUMBER 2992 MANUFACTURED BY NDC SYSTEMS,  |
| 5314 NORTH IRWINDALE AVE., IRWINDALE, CALIFORNIA 91706.  THE SOURCE IS AN    |
| INTEGRAL COMPONENT OF AN NDC MODEL 104F PAPER MACHINE FOURDRINIER MASS       |
| MEASUREMENT GAUGE.                                                           |
|                                                                              |
| "THE MATERIAL WAS PICKED UP AT OUR FRANKLIN, VIRGINIA, TRANSPORTATION        |
| DEPARTMENT LOCATION BY UPS COURIER MONDAY, JANUARY 18, 1999 FOR OVERNIGHT    |
| SHIPMENT TO NDC IN IRWINDALE.  THE UPS TRACKING NUMBER ASSIGNED WAS          |
| 1Z2923930143701285.  NDC SYSTEMS WAS CONTACTED ON 1/18/99  AND ADVISED TO    |
| EXPECT THE PACKAGE ON 1/19/99.  NDC PERSONNEL WERE REQUESTED TO ADVISE US    |
| UPON RECEIPT.  NDC PERSONNEL WERE CONTACTED 1/19/99 TO DETERMINE WHETHER THE |
| PACKAGE WAS, IN FACT, RECEIVED.  IT WAS NOT.  NDC WAS CONTACTED ON 1/20/99   |
| TO DETERMINE WHETHER THE PACKAGE WAS RECEIVED.  IT WAS NOT.  SUBSEQUENTLY,   |
| ON 1/20/99, UPS WAS CONTACTED TO REQUEST THAT THE PACKAGE BE TRACED.  UPS    |
| ASSIGNED TRACING NUMBER 020A0110 TO THE SHIPMENT.  THE PACKAGE WAS SCANNED   |
| UPON ARRIVAL IN THE UPS SYSTEM IN LOUISVILLE INTERNATIONAL IN LOUISVILLE,    |
| KY. AT 1152 P.M. ON 1/18/99.  THE MATERIAL SUBSEQUENTLY BECAME MISSING IN    |
| THE UPS SHIPPING SYSTEM.                                                     |
|                                                                              |
| "ANY EXPOSURE TO INDIVIDUALS IS EXTREMELY UNLIKELY.  THE MATERIAL WAS        |
| PACKAGED IN COMPLETE COMPLIANCE WITH DOT REGULATIONS FOR AN EXCEPTED PACKAGE |
| LIMITED QUANTITY MATERIAL AND NDC RECOMMENDED PACKAGING GUIDELINES WITH THE  |
| SOURCE SHUTTER SECURELY CLOSED.  THERE IS LESS THAN 0.1mR/HR EXPOSURE RATE   |
| 50 MILLIMETERS FROM THE FACE OF THE SHUTTERED SENSOR.  A  SURVEY WAS         |
| PERFORMED USING A TN TECHNOLOGIES MODEL 200X RADIATION SURVEY METER SERIAL   |
| NUMBER B587W  LAST CALIBRATED 10/19/98 TO CONFIRM EXPOSURE RATE.             |
|                                                                              |
| "REPRESENTATIVES OF UNION CAMP HAVE BEEN IN DAILY CONTACT WITH               |
| REPRESENTATIVES OF NDC AND UPS IN ATTEMPTS TO LOCATE THE UNIT.  INGLEHART &  |
| ASSOCIATES WAS CONSULTED FOR ADDITIONAL IDEAS IN LOCATING THE DEVICE.  TO    |
| DATE, THE DEVICE HAS NOT BEEN LOCATED.                                       |
|                                                                              |
| "FROM A UNION CAMP PROCEDURES STANDPOINT, THERE IS NO KNOWN METHOD OR        |
| MEASURE THAT CAN BE ADOPTED TO ENSURE AGAINST A RECURRENCE OF A LOSS SUCH AS |
| THIS. "                                                                      |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021
 
        