Event Notification Report for January 15, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 01/14/1999 - 01/15/1999 ** EVENT NUMBERS ** 35206 35248 35259 35260 35261 35262 35263 35264 35265 35266 +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35206 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PERRY REGION: 3 |NOTIFICATION DATE: 12/30/1998| | UNIT: [1] [] [] STATE: OH |NOTIFICATION TIME: 19:03[EST]| | RXTYPE: [1] GE-6 |EVENT DATE: 12/30/1998| +------------------------------------------------+EVENT TIME: 16:00[EST]| | NRC NOTIFIED BY: HENRY KELLY |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |MONTE PHILLIPS R3 | |10 CFR SECTION: | | |NLTR LICENSEE 24 HR REPORT | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | 24-HOUR REPORT REQUIRED BY PLANT OPERATING LICENSE DUE TO VIOLATION OF | | TECHNICAL SPECIFICATIONS | | | | The licensee has discovered that a solenoid-operated isolation valve on a | | 3/8" diameter sample line from the secondary containment was excluded from | | the plant technical specifications (TS), and, consequently, it was not | | subject to surveillances required by the TS. The valve is located on a | | secondary containment atmosphere sample line which connects to the | | post-accident sampling system. The licensee has verified that the valve is | | closed. | | | | The NRC resident inspector has been informed of this event by the licensee. | | | | * * * UPDATE AT 2117 EST ON 01/14/99 FROM BRIAN STETSON TO S. SANDIN * * * | | | | The following text is a portion of a facsimile received from the licensee: | | | | "During the extent of condition investigation of Condition Report 98-2142, | | it was identified that instrument vent and drain valves associated with the | | reactor core isolation cooling system (E51) and the annulus exhaust gas | | treatment system (M15) could fit the definition of secondary containment | | isolation valves as discussed in Technical Specification Bases 3.6.4.2. | | However, these valves are not surveilled and checked closed every 31 days as | | required by Surveillance Requirement 3.6.4.2.1. There are 12 valves (3/8") | | associated with E51, and 8 valves (1/4") associated with M15." | | | | The licensee plans to continue its evaluation and has informed the NRC | | Resident Inspector. The NRC Operations Officer notified the R3DO (Gavula). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35248 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: CLINTON REGION: 3 |NOTIFICATION DATE: 01/13/1999| | UNIT: [1] [] [] STATE: IL |NOTIFICATION TIME: 10:21[EST]| | RXTYPE: [1] GE-6 |EVENT DATE: 01/13/1999| +------------------------------------------------+EVENT TIME: 08:35[CST]| | NRC NOTIFIED BY: ROBERT POWER |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JIM GAVULA R3 | |10 CFR SECTION: | | |AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Cold Shutdown |0 Cold Shutdown | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF HALF OF THE OFFSITE EMERGENCY SIRENS DUE TO FREEZING RAIN | | | | The following text is a portion of a facsimile received from the licensee: | | | | "10CFR50.72(b)(1)(v) requires that a facility notify the NRC Operations | | Center during any event that results in a major loss of emergency offsite | | response capability. Due to weather conditions causing area power outages, | | a system test of the emergency sirens was conducted. During this test, it | | was discovered that 22 out of 44 emergency sirens were not functioning. | | Therefore, Clinton Power Station is making a notification pursuant to | | 10CFR50.72(b)(1)(v)." The licensee's current site policy is to make a | | notification of this type if less than 90% of the emergency sirens are | | available. | | | | The licensee notified the NRC resident inspector. | | | | *** UPDATE ON 01/14/99 @ 1442 EST FROM POWERS TO GOULD *** | | | | As of 0930 CST, the plant restored power to all but four emergency sirens. | | | | The NRC resident inspector will be notified by the licensee. The R3DO | | (Gavula) was notified by the NRC operations officer. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35259 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: BIG ROCK POINT REGION: 3 |NOTIFICATION DATE: 01/14/1999| | UNIT: [1] [] [] STATE: MI |NOTIFICATION TIME: 03:26[EST]| | RXTYPE: [1] GE-1 |EVENT DATE: 01/14/1999| +------------------------------------------------+EVENT TIME: 03:00[EST]| | NRC NOTIFIED BY: MIKE AZURE |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JIM GAVULA R3 | |10 CFR SECTION: | | |AENS 50.72(b)(1)(v) ENS INOPERABLE | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Decommissioned |0 Decommissioned | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF EMERGENCY NOTIFICATION SYSTEM (ENS) AND COMMERCIAL TELEPHONES | | | | At 0300, it was discovered that the FTS-2000 ENS telephone line and the | | offsite commercial telephone lines were out of service. The cause of this | | telephone outage is unknown at this time. However, the licensee stated that | | there does not seem to be a trunk line problem. The licensee has contacted | | Ameritech and a local telephone representative. Offsite communications are | | available via the use of cellular telephones and base radios to the Michigan | | State Police and to the licensee's power control (load dispatcher). Outside | | calls can be made from those locations if it is necessary for the licensee | | to relay information. | | | | (Call the NRC Operations Center for a licensee cellular telephone number.) | | | | ******************** UPDATE AT 1009 ON 01/14/99 FROM GARY RUEHLE TO TROCINE | | ******************** | | | | Telephone service was restored at approximately 0930, and the ENS line | | tested satisfactorily at 1009. The telephone outage was due to an Ameritech | | problem. | | | | The NRC operations officer notified the R3DO (Gavula). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Hospital |Event Number: 35260 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: HAWAIIAN EYE CENTER |NOTIFICATION DATE: 01/14/1999| |LICENSEE: HAWAIIAN EYE CENTER |NOTIFICATION TIME: 13:00[EST]| | CITY: WAHIAWA REGION: 4 |EVENT DATE: 01/14/1999| | COUNTY: HONOLULU STATE: HI |EVENT TIME: [HST]| |LICENSE#: 53-18343-01 AGREEMENT: N |LAST UPDATE DATE: 01/14/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |BLAIR SPITZBERG R4 | | |JOHN SURMEIER, EO NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: CYNTHIA SEMBRANO | | | HQ OPS OFFICER: STEVE SANDIN | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |LADM 35.33(a) MED MISADMINISTRATION | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LICENSEE REPORTED THAT NUMEROUS PATIENTS RECEIVED LESS THAN THE PRESCRIBED | | Sr-90 DOSE. | | | | IN 1998, TWELVE (12) PATIENTS WERE DIAGNOSED AND TREATED FOR PTERYGIUM, A | | SUPERFICIAL GROWTH ON THE LENS OF THE EYE, ELEVEN HUNDRED (1,100) RADS WAS | | PRESCRIBED FOR EACH; HOWEVER, DUE TO THE LICENSEE NOT APPLYING A DECAY | | FACTOR TO THE STRONTIUM-90 SOURCE, PATIENTS RECEIVED APPROXIMATELY 600 RADS. | | THE TWO (2) EYE APPLICATORS (SERIAL #s 0302 AND 431 - EACH 100 mCi Sr-90) | | WERE RECEIVED FROM NEW ENGLAND NUCLEAR IN MARCH 1979. THE DISCREPANCY IN | | THE PRESCRIBED VERSUS ADMINISTERED DOSE WAS DISCOVERED DURING AN ONSITE | | INSPECTION BY THE NRC ON 01/13/99. THE LICENSEE IS CONTINUING ITS | | INVESTIGATION TO DETERMINE APPROPRIATE CORRECTIVE ACTIONS. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35261 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: HARRIS REGION: 2 |NOTIFICATION DATE: 01/14/1999| | UNIT: [1] [] [] STATE: NC |NOTIFICATION TIME: 13:06[EST]| | RXTYPE: [1] W-3-LP |EVENT DATE: 01/14/1999| +------------------------------------------------+EVENT TIME: 09:18[EST]| | NRC NOTIFIED BY: MARK PALMER |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |AL BELISLE R2 | |10 CFR SECTION: | | |ARPS 50.72(b)(2)(ii) RPS ACTUATION | | |AESF 50.72(b)(2)(ii) ESF ACTUATION | | |APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 A/R Y 100 Power Operation |0 Hot Standby | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AUTOMATIC REACTOR TRIP ON TRIP OF TWO OF THREE REACTOR COOLANT PUMPS AND | | LOSS OF TWO 6.9-kV BUSES | | | | During relay calibration on the 'A' 6.9-kV non-safety bus, the bus was | | unexpectedly deenergized. The 'C' 6.9-kV bus is a swing bus and was tied to | | the 'A' 6.9-kV bus, which caused it to be deenergized also. This caused the | | loss of two of three reactor coolant pumps, and in turn, caused an automatic | | reactor trip from 100% power. All systems functioned as expected, all rods | | fully inserted, and auxiliary feedwater started on low steam generator level | | as expected. All safety systems are operable except the 'A' containment | | hydrogen analyzer which is out of service for planned maintenance. | | | | The exact cause of the loss of the 6.9-kV buses is currently under | | investigation. | | | | The licensee notified the NRC Resident Inspector, the State of North | | Carolina, and the local county. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35262 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 01/14/1999| | UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 13:38[EST]| | RXTYPE: [1] GE-4 |EVENT DATE: 01/14/1999| +------------------------------------------------+EVENT TIME: 13:11[EST]| | NRC NOTIFIED BY: RICK PLASSE |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: UNU |CURT COWGILL RI | |10 CFR SECTION: |JOHN STOLZ, NRR EO | |AAEC 50.72(a)(1)(i) EMERGENCY DECLARED |FRANK CONGEL IRO | |NOCM COMM ASST BRIEF |SULLIVAN FEMA | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE DECLARED AN UNUSUAL EVENT DUE TO A FIRE LASTING LONGER THAN 15 | | MINUTES INSIDE THE PROTECTED AREA. (REFER TO EVENT #s 35263 AND 35264 FOR | | RELATED EVENTS.) | | | | AT 1256 EST, OPERATORS RECEIVED A REPORT OF AN ONGOING FIRE IN THE VICINITY | | OF THE HYDROGEN TANK FARM AREA APPROXIMATELY 300 FEET WEST OF THE PLANT. | | THE SOURCE IS A HYDROGEN RELEASE. THE LOCATION OF THE SOURCE HAS NOT BEEN | | IDENTIFIED. THE LICENSEE EVACUATED PERSONNEL IN THE AREA AND DECLARED AN | | UNUSUAL EVENT AT 1311 EST DUE TO AN ONGOING FIRE LASTING LONGER THAN 15 | | MINUTES. OFFSITE FIRE ASSISTANCE WAS REQUESTED FROM THE SCRIBA FIRE | | DEPARTMENT. ALL PERSONNEL ARE ACCOUNTED FOR WITH ONE KNOWN MINOR INJURY. | | ALL SAFETY EQUIPMENT IS AVAILABLE. BOTH 115-kV SOURCES OF OFFSITE POWER | | WERE DEENERGIZED AS A SAFETY PRECAUTION TO ALLOW FIREFIGHTERS' ACCESS. THE | | LICENSEE IS MAINTAINING ELECTRICAL LOADS ON GENERATOR OUTPUT WITH THE | | STANDBY EMERGENCY DIESEL GENERATORS RUNNING UNLOADED. THE LICENSEE INFORMED | | NEW YORK STATE AND THE NRC RESIDENT INSPECTOR. | | | | * * * UPDATE AT 1424 EST ON 01/14/99 * * * | | | | AT 1424 EST, THE NRC ENTERED THE MONITORING PHASE OF NORMAL MODE. | | | | * * * UPDATE AT 1500 EST ON 01/14/99 * * * | | | | A COMMISSIONERS' ASSISTANTS BRIEFING WAS CONDUCTED. THE FOLLOWING | | NOTIFICATIONS WERE MADE (* OFFICE DID NOT PARTICIPATE): IRO (CONGEL AND | | WEINSTEIN); JACKSON (MILLER); DICUS (CHAN); DIAZ (HSIA); McGAFFIGAN (BEALL); | | MERRIFIELD (McCABE); EDO (HILTZ); DEDE (MITCHELL*); NRR EO (STOLZ); R1DO | | (COWGILL); PAO (GILLILAND); CAO (MADDEN); SECY (BATES); SP (LARKINS); IP | | (FAULKNER); BRIEFER (COWGILL); SRI (RASMUSSEN); AND NRR (BAWA, WONG, LONG, | | AND CONNELL). | | | | * * * UPDATE AT 1730 EST ON 01/14/99 * * * | | | | A COMMISSIONERS' ASSISTANTS BRIEFING WAS CONDUCTED. THE FOLLOWING | | NOTIFICATIONS WERE MADE: IRO (CONGEL), JACKSON (MILLER), DICUS (CHAN), DIAZ | | (HSIA), McGAFFIGAN (BEALL), MERRIFIELD (McCABE), EDO (HILTZ), BRIEFER | | (COWGILL), SRI (RASMUSSEN), AND NRR (BAWA AND WILLIAM). | | | | * * * UPDATE AT 2111 EST ON 01/14/99 FROM TOM KERR TO FANGIE JONES * * * | | | | THE LICENSEE TERMINATED THE UNUSUAL EVENT AT 2105 EST. THE LICENSEE | | INFORMED THE NRC RESIDENT INSPECTOR. | | | | * * * UPDATE AT 2120 EST ON 01/14/99 * * * | | | | THE NRC EXITED THE MONITORING PHASE OF NORMAL MODE AT 2108 EST. THE NRC | | OPERATIONS OFFICER NOTIFIED THE NRR EO (BOGER), IRO (CONGEL), AND FEMA | | (CANUPP). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35263 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 01/14/1999| | UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 14:23[EST]| | RXTYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 01/14/1999| +------------------------------------------------+EVENT TIME: 13:47[EST]| | NRC NOTIFIED BY: REVETTE |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: UNU |GENE KELLY R1 | |10 CFR SECTION: |JOHN STOLZ, NRR EO | |AAEC 50.72(a)(1)(i) EMERGENCY DECLARED |CIBOCH FEMA | | |FRANK CONGEL IRO | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE DECLARED AN UNUSUAL EVENT DUE TO PLANT'S PROXIMITY TO A | | HYDROGEN FIRE AT FITZPATRICK. (REFER TO EVENT #s 35262 AND 35264 FOR | | RELATED EVENTS.) | | | | THE LICENSEE IS DOING A PRECAUTIONARY STAFFING OF ITS TECHNICAL SUPPORT | | CENTER DUE TO THE FIRE AT FITZPATRICK. | | | | THE LICENSEE HAS NOTIFIED THE NRC RESIDENT INSPECTOR AS WELL AS STATE, | | LOCAL, AND OTHER AGENCIES. THERE WILL BE NO PRESS RELEASE. | | | | * * * UPDATE AT 2139 EST ON 01/14/99 FROM STAN LUCAS TO S.SANDIN * * * | | | | UNIT 1 EXITED THE UNUSUAL EVENT AT 2125 EST BASED ON TERMINATION OF THE | | FITZPATRICK UNUSUAL EVENT. | | | | THE LICENSEE INFORMED STATE/LOCAL AGENCIES AND THE NRC RESIDENT INSPECTOR. | | THE NRC OPERATIONS OFFICER NOTIFIED R1DO (KELLY), NRR EO (BOGER), IRO | | (CONGEL), AND FEMA (STEINDURF). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35264 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 01/14/1999| | UNIT: [] [2] [] STATE: NY |NOTIFICATION TIME: 14:23[EST]| | RXTYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 01/14/1999| +------------------------------------------------+EVENT TIME: 13:47[EST]| | NRC NOTIFIED BY: WEAVER |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: UNU |GENE KELLY R1 | |10 CFR SECTION: |JOHN STOLZ, NRR EO | |AAEC 50.72(a)(1)(i) EMERGENCY DECLARED |CIBOCH FEMA | | |FRANK CONGEL IRD | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | THE LICENSEE DECLARED AN UNUSUAL EVENT DUE TO PLANT'S PROXIMITY TO A | | HYDROGEN FIRE AT FITZPATRICK. (REFER TO EVENT #s 35262 AND 35263 FOR | | RELATED EVENTS.) | | | | THE LICENSEE IS EVACUATING PERSONNEL FROM ITS BUILDINGS LOCATED ON THE EAST | | SIDE OF THE SITE OUTSIDE THE PROTECTED AREA FENCE. THESE BUILDINGS WERE | | APPROXIMATELY SEVERAL HUNDRED YARDS FROM THE FIRE SITE. THIS ACTION WAS | | RECOMMENDED BY A LOCAL OFFICIAL BASED ON THE FIRE AT THE FITZPATRICK SITE | | WHICH BORDERS NINE MILE POINT'S EAST BOUNDARY. IT IS REPORTED THAT HYDROGEN | | WILL BE VENTED FOR SEVERAL HOURS. WIND DIRECTION IS FROM FITZPATRICK SITE | | TOWARDS NINE MILE POINT. | | | | THE NRC RESIDENT INSPECTOR WAS NOTIFIED ALONG WITH STATE, LOCAL, AND OTHER | | GOVERNMENT AGENCIES. THE LICENSEE PLANS TO ISSUE A PRESS RELEASE. | | | | * * * UPDATE AT 2139 EST ON 01/14/99 FROM STAN LUCAS TO S.SANDIN * * * | | | | UNIT 2 EXITED THE UNUSUAL EVENT AT 2125 EST BASED ON TERMINATION OF THE | | FITZPATRICK UNUSUAL EVENT. | | | | THE LICENSEE INFORMED STATE/LOCAL AGENCIES AND THE NRC RESIDENT INSPECTOR. | | THE NRC OPERATIONS OFFICER NOTIFIED THE R1DO (KELLY), NRR EO (BOGER), IRO | | (CONGEL) AND FEMA (STEINDURF). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35265 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: BROWNS FERRY REGION: 2 |NOTIFICATION DATE: 01/14/1999| | UNIT: [] [] [3] STATE: AL |NOTIFICATION TIME: 20:26[EST]| | RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4 |EVENT DATE: 01/14/1999| +------------------------------------------------+EVENT TIME: 16:40[CST]| | NRC NOTIFIED BY: RODNEY NACOSTE |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |AL BELISLE R2 | |10 CFR SECTION: | | |AINB 50.72(b)(2)(iii)(B) POT RHR INOP | | |NLCO TECH SPEC LCO A/S | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | | | | |3 N Y 100 Power Operation |100 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LICENSEE DECLARED HIGH PRESSURE COOLANT INJECTION (HPCI) INOPERABLE DUE TO | | AN OIL LEAK OBSERVED DURING START OF THE PUMP. | | | | THE FOLLOWING TEXT IS A PORTION OF A FACSIMILE RECEIVED FROM THE LICENSEE: | | | | "DURING THE PERFORMANCE OF [PROCEDURE] 3-SR-3.5.1.7, HPCI MAIN AND BOOSTER | | PUMP SET DEVELOPED HEAD AND FLOW RATE TEST, WHILE THE HPCI PUMP WAS | | STARTING, AN OIL LEAK DEVELOPED ON [VALVE] 3-SV-73-18, HPCI STOP VALVE. ONE | | STUD WAS FOUND SHEARED FROM THE STOP VALVE. HPCI WAS SUBSEQUENTLY DECLARED | | INOPERABLE, AND THE APPROPRIATE [LIMITING CONDITIONS FOR OPERATION] WERE | | ENTERED." | | | | THE LICENSEE IS CONDUCTING AN INVESTIGATION TO DETERMINE THE CAUSE OF THE | | FAILURE AND THE APPROPRIATE CORRECTIVE ACTIONS. | | | | THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35266 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 01/14/1999| | UNIT: [] [2] [3] STATE: IL |NOTIFICATION TIME: 21:27[EST]| | RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 01/14/1999| +------------------------------------------------+EVENT TIME: 20:12[CST]| | NRC NOTIFIED BY: SALGADO |LAST UPDATE DATE: 01/14/1999| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |JAMES CREED, REG 3 IAT | |10 CFR SECTION: |JOHN DAVIDSON, NMSS IAT | |DDDD 73.71 UNSPECIFIED PARAGRAPH |RICHARD ROSANO, NRR IAT | | |BRUCE BOGER, NRR EO | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N Y 100 Power Operation |100 Power Operation | |3 N Y 100 Power Operation |100 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | There was an unauthorized entry into the protected area, and immediate | | compensatory measures were taken upon discovery. (Contact the NRC | | Operations Center for additional details.) | | | | The licensee notified the NRC Resident Inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021