Event Notification Report for January 11, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 01/08/1999 - 01/11/1999 ** EVENT NUMBERS ** 35173 35228 35229 35230 35231 35232 35233 35234 35235 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35173 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: DIABLO CANYON REGION: 4 |NOTIFICATION DATE: 12/18/1998| | UNIT: [1] [] [] STATE: CA |NOTIFICATION TIME: 22:42[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 12/18/1998| +------------------------------------------------+EVENT TIME: 18:00[PST]| | NRC NOTIFIED BY: JOY SKAGGS |LAST UPDATE DATE: 01/08/1999| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |IAN BARNES R4 | |10 CFR SECTION: | | |ADAS 50.72(b)(2)(i) DEG/UNANALYZED COND | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Hot Standby |0 Hot Standby | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | RCS PRESSURE BOUNDARY LEAKAGE DISCOVERED | | | | "On 12/17/98, at 0611 hours, Unit 1 was placed in Hot Standby in order to | | perform repairs on a lube oil cooler for Reactor Coolant Pump ( RCP) 1-3. On | | 12/18/98, during routine inspections of the work area, a buildup of boric | | acid was discovered. At 1800 hours on 12/18/98, the source of the boric acid | | was determined to be RCS leakage from the lower radial bearing RTD | | thermowell on RCP 1-3. In addition, the leakage was determined to be RCS | | pressure boundary leakage. In accordance with plant Technical | | Specifications, preparations are being made to place the Unit in Cold | | Shutdown. The magnitude of the leakage is significantly less than 1 gpm." | | | | The NRC resident inspector will be informed of this event by the licensee. | | | | ******************* UPDATE AT 1649 ON 1/8/99, BY PIERCE, TAKEN BY WEAVER | | ***************************** | | | | PG&E has concluded this event is not reportable and retracts the 50.72 | | report. The basis for retracting this report is that the leakage has been | | confirmed to NOT be pressure boundary leakage. The leakage was due to a | | loose instrument fitting which is not indicative of an impending gross | | failure of the pressure boundary. Furthermore, the boric acid residue was | | removed from components in the vicinity and the effects on carbon steel | | components was evaluated. The boric acid had not seriously degraded | | components or left components in an unanalyzed condition that could | | significantly compromise plant safety. | | | | The licensee will inform the NRC resident inspector. The Operations Center | | notified the R4DO (Harrell). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35228 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: VOGTLE REGION: 2 |NOTIFICATION DATE: 01/07/1999| | UNIT: [1] [2] [] STATE: GA |NOTIFICATION TIME: 16:44[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 01/07/1999| +------------------------------------------------+EVENT TIME: 16:28[EST]| | NRC NOTIFIED BY: TOM TYNAN |LAST UPDATE DATE: 01/08/1999| | HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |LEN WERT R2 | |10 CFR SECTION: | | |AENS 50.72(b)(1)(v) ENS INOPERABLE | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | FTS AND COMMERCIAL PHONE LINES OUT OF SERVICE | | | | The licensee notified the NRC via cellular phone that both their FTS-2000 | | and their commercial lines were unavailable for dial out. However, the | | commercial lines could be accessed by dialing in from the Operations Center. | | The licensee is troubleshooting this problem and believes it may be related | | to some other work (digging) in progress. | | | | The licensee informed the NRC resident inspector. | | | | * * * UPDATE 0153 1/8/99 FROM SHFLIGER TAKEN BY STRANSKY * * * | | | | All telephones are now working properly. The NRC resident inspector will be | | informed by the licensee. Notified R2DO (Wert). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 35229 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: STATE OF LOUSIANA |NOTIFICATION DATE: 01/08/1999| |LICENSEE: EAST JEFF GENERAL HOSPITAL |NOTIFICATION TIME: 09:48[EST]| | CITY: NEW ORLEANS REGION: 4 |EVENT DATE: 01/08/1999| | COUNTY: STATE: LA |EVENT TIME: [CST]| |LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 01/08/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |PHIL HARRELL R4 | | | | +------------------------------------------------+ | | NRC NOTIFIED BY: JOE NOBLE | | | HQ OPS OFFICER: BOB STRANSKY | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT | | | | While changing sources in a high dose rate afterloader, the source became | | disconnected from the drive cable. The afterloader device is located in a | | shielded room. The licensee has contacted the vendor to retrieve the | | source. No further details were provided. A representative of the state is | | responding to the site. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35230 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PRAIRIE ISLAND REGION: 3 |NOTIFICATION DATE: 01/08/1999| | UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 10:43[EST]| | RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 01/08/1999| +------------------------------------------------+EVENT TIME: 08:52[CST]| | NRC NOTIFIED BY: MATHER |LAST UPDATE DATE: 01/08/1999| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |BRENT CLAYTON R3 | |10 CFR SECTION: | | |AESF 50.72(b)(2)(ii) ESF ACTUATION | | |NLCO TECH SPEC LCO A/S | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Hot Shutdown |0 Hot Shutdown | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AUTO START OF THE #11 TURBINE DRIVEN AUX FEED PUMP. | | | | WHILE TESTING OF THE #11 REACTOR COOLANT PUMP BREAKER WAS IN PROGRESS ON | | 4.16KV BUS 11, AN INADVERTENT UNDERVOLTAGE OCCURRED ON BUS 12 CAUSING TRIP | | OF REACTOR COOLANT PUMP (RCP) 12, PUTTING THE PLANT IN A SECOND LCO FOR | | HAVING TWO RCPS OUT OF SERVICE. THIS RESULTED IN THE INITIATING SIGNAL FOR | | THE AUTO START OF THE # 11 TURBINE DRIVEN AUX FEEDWATER PUMP. THE #11 | | TURBINE DRIVEN AUX FEED PUMP WAS SECURED WHEN THE UNDERVOLTAGE SIGNAL WAS | | CLEARED ON BUS 12 AND #12 REACTOR COOLANT PUMP WAS RESTARTED, AT WHICH TIME | | THEY EXITED THE SECOND LCO. THE CAUSE OF THIS EVENT IS BEING INVESTIGATED. | | | | THE RESIDENT INSPECTOR WAS NOTIFIED. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35231 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: VERMONT YANKEE REGION: 1 |NOTIFICATION DATE: 01/08/1999| | UNIT: [1] [] [] STATE: VT |NOTIFICATION TIME: 11:28[EST]| | RXTYPE: [1] GE-4 |EVENT DATE: 01/08/1999| +------------------------------------------------+EVENT TIME: 10:35[EST]| | NRC NOTIFIED BY: M. MAGNUSON |LAST UPDATE DATE: 01/08/1999| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |WILLIAM COOK R1 | |10 CFR SECTION: | | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | RHR SERVICE WATER PUMPS MAY NOT HAVE ADEQUATE NPSH | | | | | | A review of calculation VYC-990, R4 shows that inadequate NPSH exists for | | RHR Service Water (RHRSW) pumps. VYC-990, R4 may not have conservatively | | taken into account pump and system parameters, resulting in a condition of | | being outside the design basis of the plant for the RHRSW system. | | | | The NRC resident inspector has been informed of this event by the licensee. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Hospital |Event Number: 35232 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ST. VINCENT'S MEDICAL CENTER |NOTIFICATION DATE: 01/08/1999| |LICENSEE: ST. VINCENT'S MEDICAL CENTER |NOTIFICATION TIME: 13:50[EST]| | CITY: BRIDGEPORT REGION: 1 |EVENT DATE: 01/08/1999| | COUNTY: STATE: CT |EVENT TIME: 12:00[EST]| |LICENSE#: 06-00843-03 AGREEMENT: N |LAST UPDATE DATE: 01/08/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM COOK R1 | | |DR. COOL NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: ROBERT LANGE | | | HQ OPS OFFICER: DOUG WEAVER | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |BAE1 20.2202(b)(1) PERS OVEREXPOSURE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | POTENTIAL PERSONNEL OVEREXPOSURE | | | | A radiation oncology technologist's film badge recorded a dose of 19,490 mR | | for the month of November. The results were provided to the licensee on | | 12/18/98. The licensee requested confirmation of the results and the | | confirmation was received today, 1/8/99. | | | | The licensee does not believe the technologist actually received this dosage | | based on an interview with the employee. The employee denies being present | | during any treatments that could have resulted in the dose. The employee | | provided a blood sample and it was found to be normal. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35233 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: BYRON REGION: 3 |NOTIFICATION DATE: 01/08/1999| | UNIT: [1] [] [] STATE: IL |NOTIFICATION TIME: 15:00[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 01/08/1999| +------------------------------------------------+EVENT TIME: 13:41[CST]| | NRC NOTIFIED BY: LARRY BUNNER |LAST UPDATE DATE: 01/08/1999| | HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |BRENT CLAYTON R3 | |10 CFR SECTION: | | |ASHU 50.72(b)(1)(i)(A) PLANT S/D REQD BY TS | | |NLCO TECH SPEC LCO A/S | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |99 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | TECHNICAL SPECIFICATION REQUIRED SHUTDOWN | | | | "During testing of the 'A' train of the solid state protection system, the | | Reactor Trip breaker 'A' failed to function normally and was declared | | inoperable. Technical specifications require the unit to be placed in Mode | | 3 (shutdown condition) within 6 hours. At 1341 the ramp was initiated to | | decrease reactor power to mode 3." | | | | Technical Specifications allow six hours to reach mode 3. The six hour | | clock started at 1224. No other equipment is out of service that will | | impact the plant shutdown. The licensee notified the NRC resident | | inspector. | | | | | | ***************************** UPDATE AT 1707 ON 1/8/99, BY BUNNER TAKEN BY | | WEAVER ***************** | | | | The licensee repaired and completed testing the breaker at 1555. Power had | | been reduced to 54% and is now increasing. The Tech Spec LCO action | | statement has been exited. The licensee will inform the NRC resident | | inspector. The HOO notified the R3DO (Clayton). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 35234 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 01/08/1999| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 16:17[EST]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 01/08/1999| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 12:30[EST]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 01/08/1999| | CITY: PIKETON REGION: 3 +-----------------------------+ | COUNTY: PIKE STATE: OH |PERSON ORGANIZATION | |LICENSE#: GDP-2 AGREEMENT: N |BRENT CLAYTON R3 | | DOCKET: 0707002 |SUSAN SHANKMAN NMSS | +------------------------------------------------+JOSEPH GIITTER IRD | | NRC NOTIFIED BY: KURT SISLER | | | HQ OPS OFFICER: DOUG WEAVER | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NBNL RESPONSE-BULLETIN | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | BULLETIN 91-01 FOUR HOUR REPORT | | | | "On January 8. 1999, at 1230 hours it was discovered that no Nuclear | | Criticality Safety Approval (NCSA) was in place for the X-326 Evacuation | | Booster Station. The Evacuation Booster Station has been abandoned in place | | for more than twenty years. A UF6 negative was obtained on this equipment | | before it was isolated from the rest of the X-326 cascade equipment. | | Applied Nuclear Technology (ANTS) is analyzing to determine if greater than | | 15 grams of U235 is present. | | | | "This event is being reported under criticality control (Bulletin 91-01) | | 4-hour due to the potential that abandoned equipment contains more than 15 | | grams U235 requiring NCSA per Technical Safety Requirement 3.11.2." | | | | The NRC resident inspector was notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 35235 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: BEAVER VALLEY REGION: 1 |NOTIFICATION DATE: 01/09/1999| | UNIT: [1] [2] [] STATE: PA |NOTIFICATION TIME: 21:55[EST]| | RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 01/09/1999| +------------------------------------------------+EVENT TIME: 20:58[EST]| | NRC NOTIFIED BY: JOHN THOMAS |LAST UPDATE DATE: 01/09/1999| | HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |WILLIAM COOK R1 | |10 CFR SECTION: | | |AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF EMERGENCY SIREN CAPABILITY | | | | "At 1905, the control room received notification from the Beaver County | | Emergency Management Agency that the siren activation computer was beeping, | | but not displaying any other indication of a fault. The system is designed | | to auto-dial the control room and play a pre-recorded message when it | | detects a fault. That message was not activated. Operations personnel | | called out Telecommunications to investigate the siren computer status, but | | based on indications available, the sirens were believed to be operable. | | | | "At 2058, telecommunications personnel reported that the siren activation | | system had a loss of communication between the activation computer and the | | radio transmitter, which might have prevented the sirens from functioning | | properly if needed. This failure constitutes a loss of a significant portion | | of the Emergency Notification System. | | | | "At 2106, telecommunications personnel reported they had been successful in | | resetting the computer communication module and had tested the system | | satisfactorily. The siren activation system is currently operable." | | | | The licensee will notify the NRC resident inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021