Event Notification Report for January 5, 1999

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           01/04/1999 - 01/05/1999

                              ** EVENT NUMBERS **

35200  35212  35214  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35200       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY                    REGION:  2  |NOTIFICATION DATE: 12/28/1998|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 11:16[EST]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        12/28/1998|
+------------------------------------------------+EVENT TIME:        11:00[EST]|
| NRC NOTIFIED BY:  JAMES HELM                   |LAST UPDATE DATE:  01/04/1999|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |PIERCE SKINNER       R2      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| EMERGENCY SIRENS INOPERABLE DUE TO WINTER WEATHER                            |
|                                                                              |
| Virginia Power polled the 61 emergency sirens around Surry and found 17 that |
| did not respond.  Troubleshooting is in progress on the sirens in question.  |
| The cause of the failures is believed to be freezing rain which passed       |
| through the area on 12/24/98.  The polling was completed at 1100 EST this    |
| morning.                                                                     |
|                                                                              |
| The licensee informed the NRC resident inspector and the State of Virginia   |
| Department of Emergency Services.                                            |
|                                                                              |
| ***UPDATE AT 1012 EST ON 01/04/99 FROM WEBSTER TAKEN BY MACKINNON***         |
|                                                                              |
| The licensee reported that the emergency sirens were returned to service at  |
| 0930 EST on 01/04/99.                                                        |
|                                                                              |
| NRC resident inspector was notified of this event update by the licensee.    |
| The NRC operations officer notified the R2DO (Pierce Skinner).               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35212       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CLINTON                  REGION:  3  |NOTIFICATION DATE: 01/02/1999|
|    UNIT:  [1] [] []                 STATE:  IL |NOTIFICATION TIME: 08:51[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        01/02/1999|
+------------------------------------------------+EVENT TIME:        07:45[CST]|
| NRC NOTIFIED BY:  MARSHALL FUNKHOUSER          |LAST UPDATE DATE:  01/04/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MONTE PHILLIPS       R3      |
|10 CFR SECTION:                                 |JOHN HANNON          NRR     |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |ROSEMARY HOGAN       IRD     |
|                                                |JOSEPH HIMES         RCT     |
|                                                |CHARLES MILLER       NRR     |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LICENSEE CONCLUDED THAT THE EMERGENCY RESPONSE ORGANIZATION COULD NOT MEET   |
| THE STAFFING TIME REQUIREMENT DUE TO ADVERSE WEATHER CONDITIONS.             |
|                                                                              |
| THE FOLLOWING TEXT IS A PORTION OF A FACSIMILE RECEIVED FROM THE LICENSEE:   |
|                                                                              |
| "10CFR50.72(b)(v) REQUIRES THE FACILITY TO NOTIFY THE NRC OPERATIONS CENTER  |
| DURING ANY EVENT THAT RESULTS IN THE MAJOR LOSS OF EMERGENCY OFFSITE         |
| RESPONSE CAPABILITY."                                                        |
|                                                                              |
| "WEATHER CONDITIONS HAVE DETERIORATED DRIVING CONDITIONS PREVENTING MULTIPLE |
| PERSONNEL FROM REACHING THE PLANT.  BASED ON THESE RESULTS AND PRESENT       |
| WEATHER CONDITIONS, IT IS DOUBTFUL THAT THE EMERGENCY RESPONSE ORGANIZATION  |
| WOULD BE FILLED WITHIN THE REQUIRED TIME.  THUS, THIS NOTIFICATION [IS]      |
| BEING MADE."                                                                 |
|                                                                              |
| THE LICENSEE PLANS TO INFORM THE NRC RESIDENT INSPECTOR.                     |
|                                                                              |
| ***UPDATE ON 01/04/99 AT 1240 EST FROM R. POWERS TAKEN BY MACKINNON***       |
|                                                                              |
| WEATHER AND DRIVING CONDITIONS ARE NO LONGER HAZARDOUS, AND THE LICENSEE CAN |
| FILL THE  EMERGENCY RESPONSE ORGANIZATION POSITIONS AS OF 1135 CST ON        |
| 01/04/99.                                                                    |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS UPDATE BY THE LICENSEE.  THE |
| NRC OPERATIONS OFFICER NOTIFIED THE R3DO (BRENT CLAYTON).                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   35214       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAN ONOFRE               REGION:  4  |NOTIFICATION DATE: 01/05/1999|
|    UNIT:  [] [2] []                 STATE:  CA |NOTIFICATION TIME: 03:19[EST]|
|   RXTYPE: [1] W-3-LP,[2] CE,[3] CE             |EVENT DATE:        01/04/1999|
+------------------------------------------------+EVENT TIME:        20:51[PST]|
| NRC NOTIFIED BY:  HOWARD SMITH                 |LAST UPDATE DATE:  01/05/1999|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOSEPH TAPIA         R4      |
|10 CFR SECTION:                                 |                             |
|AINB 50.72(b)(2)(iii)(B) POT RHR INOP           |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LICENSEE DETERMINED THAT THE CCW SYSTEM MAY NOT  MEET ITS REQUIREMENT TO     |
| OPERATE FOR 7-DAYS WITHOUT MAKE-UP FOLLOWING A SEISMIC EVENT                 |
|                                                                              |
| "AT SAN ONOFRE, THE COMPONENT COOLING WATER (CCW) SYSTEM IS REQUIRED TO      |
| PROVIDE COOLING FOR 7 DAYS WITHOUT MAKE-UP.  CCW TRAINS A AND B ARE          |
| SEISMICALLY QUALIFIED; THE NON-CRITICAL LOOP IS NOT SEISMICALLY QUALIFIED.   |
|                                                                              |
| "UNIT 2 ENTERED MODE 5 AT APPROXIMATELY 0544 PST ON JANUARY 3, 1999, FOR A   |
| PLANNED REFUELING/MAINTENANCE OUTAGE.  AT 2051 ON JANUARY 4, 1999, WHILE     |
| UNIT 2 WAS IN MODE 5, SCE DETERMINED THAT ISOLATION VALVE LEAKAGE BETWEEN    |
| CCW TRAIN B AND THE CCW NON-CRITICAL LOOP OBSERVED DURING A TS SURVEILLANCE  |
| EXCEEDED IT ACCEPTABLE LIMIT FOR OPERATION IN MODES 1 THROUGH 4 AND TRAIN B  |
| CCW COULD HAVE BEEN INOPERABLE PRIOR TO SHUT DOWN.  TESTS WERE PERFORMED TO  |
| ATTEMPT TO DETERMINE WHETHER THIS LEAKAGE EXISTED DURING OPERATION IN MODES  |
| 1 THROUGH 4 PRIOR TO PLANT SHUT DOWN.  HOWEVER, THE TESTS WERE UNABLE TO     |
| DETERMINE THAT THE LEAKAGE DID NOT EXIST PRIOR TO SHUT DOWN.  DURING THE     |
| PAST CYCLE OF PLANT OPERATION, IF A SEISMIC EVENT WERE TO HAVE OCCURRED      |
| WHILE TRAIN A WAS OUT OF SERVICE, THERE WAS A POTENTIAL FOR THE CCW TO FAIL  |
| TO MEET ITS REQUIRED 7-DAYS OF OPERATION WITHOUT MAKEUP.  THEREFORE, SCE IS  |
| CONSERVATIVELY MAKING THIS REPORT AS A NON-EMERGENCY 4-HOUR REPORT IN        |
| ACCORDANCE WITH 10CFR50.72(b)(2)(iii) - A CONDITION THAT ALONE COULD HAVE    |
| PREVENTED THE FULFILLMENT OF THE SAFETY FUNCTION OF THE CCW.                 |
|                                                                              |
| "CCW IS PRESENTLY CAPABLE OF PERFORMING ITS SUPPORT FUNCTION FOR SHUT DOWN   |
| COOLING IN MODES 5 AND 6.  THE ISOLATION VALVES' ACTUATORS WERE              |
| DISCONNECTED, THE VALVES WERE MANUALLY SEATED.  THE MEASURED LEAKAGE WAS     |
| WELL BELOW THE ACCEPTABLE LEVEL FOR OPERATION IN MODES 1 THROUGH 4.  THE     |
| ACTUATORS WERE RE-CONNECTED TO PROVIDE FOR REMOTE OPERATION.  THE            |
| INVESTIGATION OF THE CAUSE AND CORRECTIVE ACTIONS IS ON-GOING..              |
|                                                                              |
| "UNIT 3 IS IN MODE 1 AND UNAFFECTED BY THIS CONDITION."                      |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+