Resolution of Generic Safety Issues: NMSS-0006. Criticality in Low-Level Waste (Rev. 1) ( NUREG-0933, Main Report with Supplements 1–34 )
DESCRIPTION
This issue was identified1708 by NMSS and addresses the potential for special nuclear material containing unusual moderators to re-concentrate and form a critical mass in low-level waste disposal systems. The results of studies of two low-level waste sites indicated that criticality is not likely when the moderators silicon dioxide and water are present. However, the results of studies of containerized waste indicated that the presence of the moderators carbon and beryllium in excess of 5 times the mass of U235 served to reduce the areal density of fissile material required for criticality.
CONCLUSION
The issue was given a medium priority ranking and resolution was pursued.1708 In October 1998, SECY-98-239 was issued with a recommendation to cease research on criticality concerns with unusual moderators, such as beryllium and graphite. The staff concluded that significant sources of unusual moderators were not present at low-level waste (LLW) facilities. Even if significant quantities of unusual moderators were present in LLW, the staff believed that it was unlikely that they would be commingled with special nuclear material to create a critical array. In December 1998, the Commission issued an SRM approving the staff's recommendation to cease further research. The staff was directed by the Commission to continue development of guidance on emplacement criticality controls at LLW facilities. Thus, the issue was resolved.1771