Event Notification Report for January 4, 2005

… in May 2004 Power Reactor Event Number: 41302 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … will notify the NRC Resident Inspector. * * * UPDATE FROM DIABLO CANYON (J. WELSCH) TO M. RIPLEY 0945 EST 12/31/04 * * …

Event Notification Report for January 14, 2011

… ** 46531 46534 Power Reactor Event Number: 46531 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … BECAME INOPERABLE "On January 10, 2011, at 1321 PST, Diablo Canyon Power Plant, Unit 2, entered Technical …

Event Notification Report for February 24, 2016

… RETRACTED !!!!! Power Reactor Event Number: 51655 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … that does not involve a hostile action was reported by the Diablo Canyon security watch commander. At 1443 PST on …

Event Notification Report for January 19, 2016

… LA-150023 Power Reactor Event Number: 51655 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … that does not involve a hostile action was reported by the Diablo Canyon security watch commander. At 1443 PST on …

Event Notification Report for January 15, 2016

… been notified. Power Reactor Event Number: 51655 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … that does not involve a hostile action was reported by the Diablo Canyon security watch commander. At 1443 PST on …

Event Notification Report for May 21, 2020

… has been notified." Part 21 Event Number: 54721 Rep Org: Diablo Canyon Licensee: Marsh Bellofram Region: 4 City:   State: CA … THERMOCOUPLES The following is a summary from the Diablo Canyon Part 21 Report submitted: On May 18, 2020, …

Event Notification Report for March 14, 2011

… been notified. Power Reactor Event Number: 46668 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … warning issued by the NOAA for the California West Coast. Diablo Canyon Power Plant [DCPP] has implemented the …

Event Notification Report for March 1, 2012

… Fuel Storage Installation Event Number: 47580 Rep Org: DIABLO CANYON Licensee: PACIFIC GAS & ELECTRIC CO. Region: 4 City: … 9, 2012, at 1405 [PST], plant personnel notified the Diablo Canyon shift manager that a nut on a hold-down stud …

Event Notification Report for March 13, 2012

… been notified." Power Reactor Event Number: 47733 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … 2012, a non-work related on-site fatality occurred at the Diablo Canyon Power Plant. The fatality was not related to …

Event Notification Report for April 26, 2012

… 47864 47865 Power Reactor Event Number: 47858 Facility: DIABLO CANYON Region: 4 State: CA Unit: [1] [2] [ ] RX Type: [1] … ALTERNATE POWER CIRCUITS "On April 21, 2012, at 1615 PDT, Diablo Canyon Power Plant (DCPP) operators identified that …