… of Struthers-Dunn Operate-Reset Relay Latch Failures for Salem Generating Station Condition Reports CR 960906195 CR … team was formed by the NBU's Senior Vice President - Nuclear Engineering to evaluate the relay problem and …
Part 21 Report - 1996-742
… Company Hancocks Bridge, NJ 08038 Senior Vice President - Nuclear Engineering LR-N96274 SEP 06 1956 United States … 10 CFR 21 NOTIFICATION, NUS SUMMATOR AND ISOLATOR MODULES SALEM GENERATING STATION UNITS 1 AND 2 FACILITY OPERATING LICENSE …
Part 21 Report - 1996-880
… #: 9609100105 LICENSEE EVENT REPORT (LER) FACILITY NAME: SALEM GENERATING STATION UNIT 2 PAGE: 1 OF 4 DOCKET NUMBER: … and internals that was undetected by the overhaul vendor (Nuclear Logistics Inc.). The corrective actions included …
Part 21 Report - 2000-111
… Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit United States Nuclear Regulatory … Number 301-816-5100 Subject: INITIAL 10 CFR 21 NOTIFICATION SALEM GENERATING STATION UNITS 1 AND 2 FACILITY OPERATING LICENSE …
Part 21 Report - 2000-041
… Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit APR 12 2000 LR-N000132 United States … TO 10CFR2I INTERIM REPORT, GE MODEL CR2940U301 SWITCH SALEM GENERATING STATION UNITS I AND 2 FACILITY OPERATING LICENSE …
Part 21 Report - 2000-042
… Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit JUN 15 2000 LR-N000249 United States … TO 10CFR2I INTERIM REPORT, GE MODEL CR2940U301 SWITCH SALEM GENERATING STATION UNITS I AND 2 FACILITY OPERATING LICENSE …
Part 21 Report - 1998-261
… ComEd March 16, 1998 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555-001 Subject: Dresden Nuclear Generating Station Units 2&3; NRC Dockets: 50-237 and 50-249 … District Fort Calhoun x Public Service Electric & Gas Co. Salem 1 x Public Service Electric & Gas Co. Salem 2 x …
Part 21 Report - 1995-132
… #: 9503090138 LICENSEE EVENT REPORT (LER) FACILITY NAME: Salem Generating Station - Unit 1 PAGE: 1 OF 7 DOCKET NUMBER: … earthquake, and environmental effects of pipe ruptures. The Nuclear Regulatory Commission (NRC) granted discretionary …
Part 21 Report - 2000-043
… Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit JUL 7 2000 LR-N000261 United States … REPORTABILITY DETERMINATION, GE MODEL CR2940U301 SWITCH SALEM GENERATING STATION UNITS I AND 2 FACILITY OPERATING LICENSE …
Part 21 Report - 1998-260
… LASALLE, AND QUAD CITIES. THIS NOTIFICATION REFERENCED A GE NUCLEAR ENERGY TRANSFER OF INFORMATION DATED JANUARY 23, … ARE NOT INSTALLED AT ITS BRAIDWOOD, BYRON, OR ZION NUCLEAR GENERATING STATIONS. HOWEVER, COMMONWEALTH EDISON NUCLEAR … 3; MAIN YANKEE; INDIAN POINT 3; SEABROOK; FORT CALHOUN; SALEM UNITS 1 AND 2; AND VOGTLE UNITS 1 AND 2. … Part 21 …