Part 21 Report - 1996-821

… uncorrected. Background A deviation was determined by Callaway Nuclear Plant during testing of six type HFD3045 and HFD3060 molded … technician using the wrong test procedure. The shunt trip units were installed incorrectly but would still trip the …

Part 21 Report - 1996-820

… CIRCUIT BREAKERS WITH INCORRECTLY INSTALLED DC SHUNT TRIP UNITS AND MISSING SHUNT TRIP BARRIERS CALLAWAY IDENTIFIED A DEVIATION DURING TESTING OF 6 TYPE … 6 REFERENCED ABOVE) HAD BEEN SHIPPED ONLY TO THE CALLAWAY PLANT. SUBSEQUENT OPERABILITY OF THESE BREAKERS AFTER A TRIP …

Part 21 Report - 1997-572

… regarding this issue to potentially impacted plans. The plants are identified in the NSAL. If you have any questions … NUCLEAR SAFETY ADVISORY LETTER Energy Systems Business Unit THIS IS A NOTIFICATION OF A RECENTLY IDENTIFIED … 1 & 2 Catawba Units 1 & 2 Turkey Point Unit 3 Wolf Creek Callaway Point Beach Unit 1 Yonggwang Units 1 & 2 Maanshan …

Part 21 Report - 1995-067

… REPORT DATE: 06/28/94 OTHER FACILITIES INVOLVED: Byron, Unit 2 DOCKET NO: 05000455 OPERATING MODE: 1 POWER LEVEL: … under a certain set of conditions. However, when the plant is outside of these conditions, the BDPS subsystem may … BDPS. A partners was formed with Comanche Peak, Wolf Creek, Callaway, Braidwood and Byron, with Comanche Peak being the …

Part 21 Report - 2003-007-00

… prior testing of numerous coatings for use in nuclear power plants we have not seen any detrimental performance when … Two Rivers, WI Prairie Island - Welch, MN AmerenlUE-CIPS - Callaway Plant Duke Energy Corp - Nuclear Assessment … Rochester, NY TXU Electric - Glen Rose, TX February 13,2003 United States Nuclear Regulatory Commission Document Confrol …

Part 21 Report - 1996-900

… Energy NUCLEAR SAFETY ADVISORY LETTER Systems Business ESBU Unit THIS IS A NOTIFICATION OF A RECENTLY IDENTIFIED … Basic Component: RCP Supports Date: Nov. 10, 1994 Plants: See Page 2, Table 1 Substantial Safety Hazard or … C. Summer Shearon Harris Vogtle 1 & 2 Seabrook Wolf Creek Callaway Comanche Peak 1 & 2 Sequoyah 1 & 2 Watts Bar 1 & 2 …

Part 21 Reports - 2006

… Fairbanks Morse Engine Woodward Digital Reference Unit (DRU) 1/12/2006 EN 40699 ML060250260 2006-01-01 ESI … Seat Inserts 06/13/2006 EN 42637 ML061660131 2006-13-00 Callaway Barton pressure transmitter -- exposed wiring … (Foxboro Replacement Modules) Supplied to Nuclear Power Plants 12/14/2006 EN 43052 ML063520131 2006-27-00 V. C. …

Part 21 Report - 1997-193

… by American Electric Power REFERENCE: Donald C. Cook Plant, Units 1 and 2 Docket Numbers 50-315 and 50-316 Operating … Page 22 of 32 Dated: April 23, 1997 Union Electric Company Callaway Plant VETIP Coordinator P. O. Box 620 Fulton, MO …

Part 21 Report - 1997-062

… MAILING LIST LICENSEES Alabama Power Company Farley Nuclear Plant J. Woodward Plant Manager Columbia, AL 36319 Alabama … Power Plant Daniel I. Geneva Supervisor Vendor Audits Unit Nuclear Quality Assurance Department 1650 Calvert … P. O. Box 149 St Louis, MO 63166 Union Electric Company Callaway Plant VETIP Coordinator P. O. Box 620 Fulton, MO …