Material Property Correlations: Comparisons between FRAPCON-3.5, FRAPTRAN 1.5, and MATPRO (NUREG/CR-7024, Revision 1)
On this page:
Download complete document
Publication Information
Manuscript Completed: May 2014
 Date Published: October 2014
Prepared by:
 W.G. Luscher and K.J. Geelhood
Pacific Northwest National Laboratory
 Richland, WA 99352
P. Raynaud, NRC Project Manager
NRC Job Code V6197
Office of Nuclear Regulatory Research
 U.S. Nuclear Regulatory Commission
 Washington DC 20555-0001
Abstract
The U.S. Nuclear Regulatory Commission uses the computer codes FRAPCON-3 and FRAPTRAN to model steady-state and transient fuel behavior, respectively, to support regulatory analyses. In this document, material property correlations for oxide fuels and cladding materials are presented and discussed. Comparisons are made between the material property correlations used in the most recent versions of the codes, FRAPCON-3.5 and FRAPTRAN-1.5. Comparisons are also made with MATPRO, which is a compilation of material property correlations with an extensive history of use with various fuel performance and severe accident codes. In addition to model-to-model comparisons, model-to-data comparisons and source codes for the FRAPCON-3.5 and FRAPTRAN-1.5 correlations are provided.
Page Last Reviewed/Updated Wednesday, March 24, 2021