The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Crack Growth Rates in a PWR Environment of Nickel Alloys from the Davis-Besse and V.C. Summer Power Plants (NUREG/CR-6921)

On this page:

Download complete document

Publication Information

Manuscript Completed: November 2005
Date Published: November 2006

Prepared by:
B. Alexandreanu, O. K. Chopra and W. J. Shack

Argonne National Laboratory
9700 South Cass Avenue
Argonne, IL 60439

W.H. Cullen, Jr., NRC Project Manager

Prepared for:
Division of Fuel, Engineering and Radiological Research
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

NRC Job Code Y6388

Availability Notice

Abstract

In light water reactors (LWRs), vessel internal components made of nickel–base alloys are susceptible to environmentally assisted cracking. A better understanding of the causes and more effective mechanisms of this cracking may permit more accurate assessments of damage accumulation and requirements on inspection intervals. A program is under way at Argonne National Laboratory to evaluate the resistance of Ni alloys and their welds to environmentally assisted cracking in simulated LWR coolant environments. This report presents crack growth rate (CGR) results for the following nickel alloys tested in a simulated LWR environment: Alloy 600 removed from the Davis–Besse control rod drive mechanism nozzle #3, Alloy 182 from a J–groove weld nozzle #11 from Davis–Besse, and Alloys 182 and 82 from a hot–leg nozzle–to–pipe weld of the V.C. Summer reactor coolant system. The results from the present study are compared with the existing CGR data for Ni alloys to determine the relative susceptibility of these particular heats of material to environmentally enhanced cracking. Under cyclic loading, the Alloy 600 nozzle exhibited significant environmental enhancement, but little or no environmental enhancement was evident for the weld alloys from both Davis-Besse and V.C. Summer. Under constant load, the CGRs of the Alloy 600 nozzle are a factor of 4–8 higher than the median CGRs based on all the available data for Alloy 600 materials. This material exhibited predominantly intergranular fracture, even during precracking under cyclic loads. For both the Davis-Besse and V.C. Summer weld alloys, the CGRs under constant load are lower than those predicted by the disposition curve proposed for Alloy 182 weld metals.

Page Last Reviewed/Updated Wednesday, March 24, 2021