The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Advanced NDE for Steam Generator Tubing (NUREG/CR-6638)

On this page:

Download complete document

Publication Information

Manuscript Completed: October 1999
Date Published: January 2000

Prepared by:
S. Bakhtiari, D. S. Kupperman

Argonne National Laboratory
9700 South Cass Avenue
Argonne, IL 60439

J. Muscara, NRC Project Manager

Prepared for:
Division of Engineering Technology
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

NRC Job Code W6487

Availability Notice

Abstract

This report provides an assessment of various advanced nondestructive evaluation (NDE) techniques for inservice inspection of steam generator tubing. Selected results are presented on the application of data processing and visualization techniques; data analysis, including depth sizing and the development of correlations between eddy current signals and tube failure pressure by multivariate regression and neural networks; inspection of sleeved tubes; applications of ultrasonic NDE; and related work on emerging NDE technology.

Page Last Reviewed/Updated Wednesday, March 24, 2021