Advanced Human-System Interface Design Review Guideline: Evaluation Procedures and Guidelines for Human Factors Engineering Reviews (NUREG/CR-5908, BNL-NUREG-52333, Volume 2)

On this page:

Download complete document

Publication Information

Manuscript Completed: June 1994
Date Published: July 1994

Prepared by: 

J. M. O'Hara, W. S. Brown, Brookhaven National laboratory
C. C. Baker, D. L Welch, T. M. Granda, P. J. Vingelis, Carlow International Incorporated

Brookhaven National Laboratory
Upton, NY 11973-5000

Carlow International Incorporated
Falls Church, VA 22042

Prepared for:
Division of Systems Research
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
NRC FIN L1317

Availability Notice

Abstract

Advanced control rooms will use advanced human-system interface (HSI) technologies that may have significant implications for plant safety in that they will affect the operator's overall role in the system, the method of information presentation, and the ways in which operators interact with the system. The U.S. Nuclear Regulatory commission (NRC) reviews the HSI aspects of control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported to protect public health and safety. The principal guidance available to the NRC, however, was developed more than ten years ago, well before these technological changes. Accordingly, the human factors guidance needs to be updated to serve as the basis for NRC review of these advanced designs. The purpose of this project was to develop a general approach to advanced HSI review and the human factors guidelines to support NRC safety reviews of advanced systems. This two-volume report provides the results of the project. Volume 1 describes the development of the Advanced HSI Design Review Guideline (DRG) including (1) its theoretical and technical foundation, (2) a general model for the review of advanced HSIs, (3) guideline development in both hard-copy and computer-based versions, and (4) the tests and evaluations performed to develop and validate the DRG. Volume 1 also includes a discussion of the gaps in available guidance and a methodology for addressing them. Volume 2 provides the guidelines to be used for advanced HSI review and the procedures for their use.

Page Last Reviewed/Updated Monday, December 22, 2025

Page Last Reviewed/Updated Monday, December 22, 2025