Development of a Computer Tool for In-Depth Analysis and Post Processing of the RELAP5 Thermal Hydraulic Code (NUREG/IA-0253)
On this page:
Download complete document
Publication Information
Manuscript Completed: April 2003
Date Published: April 2011
Prepared by:
Roberto Herrero Santos* and José María Izquierdo Rocha*
*Consejo de Seguridad Nuclear
Justo Dorado, 11
28040 Madrid – Spain
A. Calvo, NRC Project Manager
Prepared for:
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
Under the International Code Assessment and Maintenance Program (CAMP)
Availability Notice
Abstract
The Spanish Nuclear Safety Council (CSN) has sponsored the development of a computer tool for the error diagnosis and interpretation of the results obtained with the code RELAP5/MOD3.2.
The report describes the tests used to check the consistency of the results and illustrates some application examples that point out some defficiencies in the code.