RELAP5/MOD3.3 Assessment against New PMK Experiments (NUREG/IA-0229)
On this page:
Download complete document
Publication Information
Manuscript Completed: August 2006
Date Published: June 2010
Prepared by:
P. Kral
Nuclear Research Institute Rez
Husinec-Rez 130
250 68 Rez, Czech Republic
A. Calvo, NRC Project Manager
Prepared for:
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
The results of RELAP5 post-test analysis of 3 tests performed on the PMK integral test facility are presented and discussed. The Hungarian facility PMK is a scaled-down model of NPP with VVER-440/213 reactor. The code version RELAP5/MOD3.3 Path02 has been assessed against the experimental data from the tests T2.1, T2.2, and T2.3. The tests were focused on medium-break LOCA without HPSI. Generally, RELAP5 predictions are in very good agreement with the measured data.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021