Information Notice No. 83-78: Apparent Improper Modification of a Component Affecting Plant Safety
SSINS No.: 6835
IN 83-78
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555
November 17, 1983
Information Notice No. 83-78: APPARENT IMPROPER MODIFICATION OF A
COMPONENT AFFECTING PLANT SAFETY
Addressees:
All nuclear power reactor facilities holding an operating license (OL) or
construction permit (CP).
Purpose:
This information notice is provided as a notification of the apparent
improper modification of a component affecting plant safety. The events
described below involve a power operated relief valve (PORV). However, the
area of concern is not limited to PORVs, but rather, relates to the
modification of any component that affects plant safety. No specific action
is required in response to this information notice, but it is expected that
recipients will review the information presented for applicability to their
facilities.
Description of Circumstances:
On September 19, 1983, the Sacramento Municipal Utility District notified
the NRC resident inspector that while bringing the Rancho Seco Nuclear
Generating Station into a condition where the once through steam generator
tube leaks could be repaired, the pressurizer PORV opened. At the time of
the opening, the reactor coolant system was at 135F and 29 psig. The
event was terminated by closing the PORV block valve. After the event, the
pressure had dropped approximately 10 psig and the PORV was apparently still
open.
Bench testing of a spare PORV, by the utility, indicated that the valve
opened at 8 psig and reseated between 30 and 50 psig. However, when this
spare valve was modified in a manner similar to that of the operating PORV,
it opened at 30 psig and did not reseat at pressures as high as 575 psig.
The modification to the operating PORV had been accomplished in May 1979. It
consisted of adding an indicator to the valve's operating lever. This
indicator was visible in the control room, via closed circuit television,
and provided an indication of whether the PORV was open or closed. Sometime
between May 1979 and the start of the 1983 refueling outage, this indicator
fell off the operating lever. It was reinstalled during the recently
completed refueling outage.
8311010018
.
IN 83-78
November 17, 1983
Page 2 of 2
Based on this testing, the utility concluded that the cause of the problem
was the weight of the indicator. Therefore, utility personnel removed the
indicator and will use a contrasting background to permit visual indication
of the operating lever, itself, via the television monitor.
Conversations with the PORV manufacturer indicated that it had not been
consulted on the modification before the utility performed it. In fact, the
first time the manufacturer knew about the modification was when it was
notified of the valve's maloperation of September 19, 1983.
It also appears that the PORV had not been tested after the modification had
been made. As evidenced by the later bench testing of the spare PORV, had
post modification testing been performed, it would have quickly pointed out
the shift in operating characteristics of the modified PORV.
In summary, this event points out two important facets of component
modification which are dictated by good practice, but which can easily be
overlooked in the rush to get the plant back on line--namely:
1. Consultation with the component manufacturer before making the
modification; and
2. Testing of component after making the modification.
Actions 2.2 and 3.2 of Generic Letter 83-28, "Required Actions Based on
Generic Implications of Salem ATWS Events," addressed the establishment of
vendor interface and post-maintenance test programs for components affecting
plant safety. Had a rudimentary vendor interface and/or post-maintenance
test program been in effect for such components, it is reasonable to assume
that this PORV maloperation could have been averted.
No written response to this notice is required. If you have any questions
regarding this matter, please contact the appropriate NRC Regional Office,
or this office.
Edward L. Jordan Director
Division of Emergency Preparedness
and Engineering Response
Office of Inspection and Enforcement
Technical Contact: R. J. Kiessel, IE
49-28119
Attachment:
List of Recently Issued IE Information Notices
.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021