The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Report on ECCS Cladding Models, NUREG-0630 (Generic Letter 80-106)



GL80106 

                               UNITED STATES 
                       NUCLEAR REGULATORY COMMISSION 
                          WASHINGTON, D.C.  20555 
                                     
                             November 28, 1979 

TO ALL PENDING OPERATING LICENSEES AND CONSTRUCTION PERMIT APPLICANTS TO ALL
LICENSEES OF PLANTS UNDER CONSTRUCTION 

SUBJECT:  REPORT ON ECCS CLADDING MODELS 

On November 1, 1979, we met with reactor fuel vendors, some plant licensees,
and other interested parties to discuss recently developed staff views on 
cladding rupture, swelling, and coolant blockage that could result from 
reactor accidents. Based on a preliminary evaluation of the correlations 
being developed, the NRC staff determined that parts of the ECCS models 
might be non-conservative in this area and therefore might not be in 
compliance with Appendix K of 10 CFR 50. We understand from the discussions 
at the meeting, confirmed by vendor letters of November 2, 1979, that 
differences between the present models and our preliminary correlations are 
either small within the limited range of applicability or that these 
differences do not produce large changes in peak cladding temperature. In 
either case we now understand that such differences should not, affect 
compliance with the temperature limit specified in 10 CFR 50.46 for licensed 
operating reactors. On this basis it might be expected that the effect on 
plants under review would also be small, but that effect has not yet been 
determined. 

We are transmitting herewith our draft report on cladding rupture 
temperature, strain, and resulting assembly flow blockage; this report 
provides a full discussion of the information we presented at the November 
1, 1979 meeting. Should you desire to comment on this draft report, 
"Cladding Swelling and Rupture Models for LOCA Analysis," please provide us 
with written comments by December 10, 1979. Because we are requesting a 
critique that will help ensure the technical quality of the final report, we 
request that the focus of your comments be technical in nature. You may also 
wish to address the topics for discussion that we have sent to the fuel 
vendors and which are set forth in the enclosure to this letter. We also 
welcome comments and suggestions on clarity so that the final report can be 
made complete and explicit on correlation derivation and use. 

                                        Sincerely, 


                                        D. B. Vassallo, Acting Director 
                                        Division of Project Management 
                                        Office of Nuclear Reactor Regulation 

Enclosures:
1.   Draft Report of NUREG-0630 
2.   Topics for Discussion

ccs:  Service Lists 
.

                                                               ENCLOSURE 2 
                           Topics for Discussion 

1.   Confirm that the Zircaloy cladding models displayed in Section 4.0 and 
     which are referenced in Section 5.0 are the models that are used in 
     your licensing LOCA analyses. Confirm that your models have been 
     displayed accurately (i.e., to within + - 5%). If you are unable to 
     respond affirmatively to the above requests, provide the appropriate 
     references and describe the discrepancies. 
     
2.   The location, magnitude, and shapes of superplastic strain peaks and 
     low-ductility valleys cannot be determined precisely from prototypical 
     rod burst tests because there are too few such experiments with enough 
     controlled variables. Do you have any information that could suggest 
     altering the shapes and magnitudes of the strain and blockage 
     correlation curves? 

3.   Most of the recent (since 1974) prototypical data were supported by 
     public funds and are publically available. It therefore appears 
     practical and beneficial to develop standardized rupture temperature, 
     strain, and blockage curves. The curves in the report (or modifications
     that we might make) could serve as an interim licensing standard, and 
     an industry standards committee could develop revised curves based on 
     present and future research results. 

4.   It may be appropriate to require that approved vendor cladding models 
     be revised to conform with the correlations that will appear in the 
     final version of the report. If your present models are in agreement 
     with, or conservatively overpredict, the NRC correlations over the 
     range of temperature and stress of interest, and if you wish not to 
     change your present curves, your ECCS model revision could simply 
     consist of explicit limits on the range of applicability of your 
     correlations. 
     
5.   The alpha-plus-beta strain and blockage "valleys" portray a real 
     phenomenon, but the exact location of the very steep sides of the 
     valley may be unknowable for real LOCA conditions. Sensitivity analyses 
     could be done to account for uncertainties in the location of the 
     curves and in prediction of the rupture temperature and stress, but 
     this would have the effect of narrowing the allowable calculated valley 
     and creating a pseudo singularity in the analysis. It might be better 
     for the licensing analysis to be insensitive to this feature. 
     
6.   The on-going NRC research program has produced data over a wide range 
     of conditions. Based on discussions with those performing licensing 
     LOCA analyses, it appears that the actual range of interest may be 
     quite narrow, and that the future program could be beneficially focused 
     on a narrower range. 
.

                       PLANTS UNDER CONSTRUCTION 

1.   Palo Verde 1/2/3              50-528, 50-529, 50-530 
2.   Perry 1/2                     50-440, 50-441 
3.   Cherokee 1/2/3                50-491, 50-492, 50-493 
4.   Beaver Valley 2               50-412 
5.   St. Lucie                     50-389 
6.   Vogtle 1/2                    50-424, 50-425 
7.   River Bend                    50-458, 50-459 
8.   Clinton 1/2                   50-461, 50-462 
9.   Forked River                  50-363 
10.  Wolf Creek 1                  50-482 
11.  Jamesport 1/2                 50-516, 50-517 
12.  Nine Mile Point 2             50-410 
13.  Millstone 3                   50-423 
14.  Bailly 1                      50-367 
15.  Limerick 1/2                  50-352, 50-353 
16.  Hope Creek                    50-354, 50-355 
17.  Marble Hill 1/2               50-546, 50-547 
18.  Seabrook 1/2                  50-443, 50-444 
19.  Sterling                      50-485 
20.  Hartsville 1/2/3/4            50-518, 50-519, 50-520, 50-521 
21.  Phipps Bend 1/2               50-553, 50-554 
22.  Yellow Creek 1/2              50-566, 50-567 
23.  North Anna 3/4                50-404, 50-405 
24.  WPPSS 1/3/4/5                 50-460, 50-508, 50-513, 50-509 
25.  Callaway 1/2                  50-483, 50-486 
26.  Harris 1/2/3/4                50-400, 50-401, 50-402, 50-403
.

                         PLANTS UNDER CP REVIEW 

1.   Pilgrim 2                     50-471 
2.   Greenwood 2/3                 50-452, 50-453 
3.   Perkins 1/2/3                 50-488, 50-489, 50-490 
4.   Allens Creek 1                50-466 
5.   New England 1/2               50-568, 50-569 
6.   Montague 1/2                  50-496, 50-497 
7.   New Haven 1/2                 50-596, 50-597 
8.   Erie 1/2                      50-580, 50-581 
9.   Pebble Springs 1/2            50-514, 50-515 
10.  Clinch River                  50-537 
11.  Black Fox 1/2                 50-556, 50-557 
12.  Skagit 1/2                    50-522, 50-523 
13.  Davis Besse 2/3               50-500, 50-501 
14.  Haven                         50-502 
15.  Greene County 1               50-549 
16.  FNP                           50-437
.

                         PLANTS UNDER OL REVIEW 

1.   Farley 2                      50-364
2.   Byron/Braidwood               50-454, 455, 456, 457 
3.   LaSalle 1/2                   50-373, 374 
4.   Zion 1/2                      50-295, 304 
5.   Midland 1/2                   50-329/330 
6.   Catawba                       50-413, 414 
7.   McGuire                       50-369, 370 
8.   So. Texas 1/2                 50-498, 499 
9.   Shoreham                      50-322 
10.  Waterford                     50-382 
11.  Grand Gulf 1/2                50-416, 417 
12.  Diablo Canyon 1/2             50-275, 323 
13.  Susquehana 1/2                50-387, 388 
14.  Salem 2                       50-311 
15.  Summer 1                      50-395 
16.  San Onofre 2/3                50-361, 362 
17.  Bellefonte 1/2                50-438, 439 
18.  Watts Bar 1/2                 50-390, 391 
19.  Sequoyah 1/2                  50-327, 328 
20.  Comanche Peak 1/2             50-445, 446 
21.  North Anna 2                  50-339 
22.  WPPSS-2                       50-397 
23.  Fermi 2                       50-341 
24.  Zimmer 1                      50-358

 

Page Last Reviewed/Updated Tuesday, March 09, 2021