United States Nuclear Regulatory Commission - Protecting People and the Environment
Home > NRC Library > Document Collections > Reports Associated with Events > Power Reactor Status Reports > 2014 > May 7

Power Reactor Status Report for May 7, 2014

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 0 04/18/2014 CORE RELOAD COMPLETE *  
Calvert Cliffs 1 100   HIGH SYSTEM VOLTAGE ACTION    
Calvert Cliffs 2 100   HIGH SYSTEM VOLTAGE ACTION    
FitzPatrick 95   REDUCED POWER FOR ROD PATTERN ADJUSTMENT *  
Ginna 0 04/27/2014 DEFUELED    
Hope Creek 1 100   HIGH SYSTEM VOLTAGE ACTION    
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 0 04/05/2014 REFUELING OUTAGE    
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 98   GENERATION LIMITED BY OFFSITE LINE OUTAGE    
Salem 2 0 04/12/2014 REFUELING OUTAGE    
Seabrook 1 100        
Susquehanna 1 0 04/12/2014 REFUELING OUTAGE HIGH SYSTEM VOLTAGE ACTION    
Susquehanna 2 100   HIGH SYSTEM VOLTAGE ACTION    
Three Mile Island 1 100   HIGH SYSTEM VOLTAGE ACTION    
Vermont Yankee 100        

Region 2

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 0 05/06/2014 REACTOR SCRAM (SEE EN# 50090) * 1
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 0 05/06/2014 REFUELING OUTAGE *  
Catawba 2 100     *  
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 0 04/14/2014 REFUELING OUTAGE    
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 79   COASTDOWN TO REFUELING OUTAGE    
Summer 0 04/04/2014 DEFUELED    
Surry 1 100        
Surry 2 0 04/20/2014 DEFUELED    
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 99   CONDENSER BACKPRESSURE *  

Region 3

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 0 05/02/2014 REFUELING OUTAGE    
Byron 1 100        
Byron 2 100        
Clinton 98   100% ELECTRICAL CAPABILITY *  
D.C. Cook 1 100   HIGH SYSTEM VOLTAGE ACTION    
D.C. Cook 2 100   HIGH SYSTEM VOLTAGE ACTION    
Davis-Besse 7   INCREASING POWER *  
Dresden 2 60   INCREASING POWER *  
Dresden 3 100        
Duane Arnold 100        
Fermi 2 100        
La Salle 1 100        
La Salle 2 20   INCREASING POWER *  
Monticello 89   ENGINEERING HOLD FOR EPU TESTING *  
Palisades 100        
Perry 1 100   HIGH SYSTEM VOLTAGE ACTION *  
Point Beach 1 100        
Point Beach 2 97   PLANT TESTING    
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 12   HOLDING POWER FOR TURBINE ROLL PREPARATIONS *  

Region 4

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 72   HOLDING POWER FOR GRID STABILIZATION    
Arkansas Nuclear 2 0 04/27/2014 FORCED OUTAGE    
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 12   OFFLINE FOR MAIN TRANSFORMER REPAIR    
Palo Verde 2 93   INCREASING POWER *  
Palo Verde 3 100        
River Bend 1 100        
South Texas 1 0 03/15/2014 REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 0 04/12/2014 REFUELING OUTAGE    
Wolf Creek 1 0 03/07/2014 PLANT HEATUP IN PROGRESS    

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
Page Last Reviewed/Updated Wednesday, June 04, 2014
Wednesday, June 04, 2014