Part 21 Report - 1995-210
HARRIS 1 29397 09-27-95 POW LICENSEE: CAROLINA POWER & LIGHT CO. SITE: .HARRIS 1 . EN NUMBER:29397 DOCKET: 05000400 EVENT DATE: 09-27-95 RX TYPE: PWR EVENT TIME: 00:00 VENDORS: W-3-LP NOTIFY DATE: 09-29-95 EMERGENCY CLASS: N/A REGION: 2 STATE: NC TIME: 16:27 OPS OFFICER: RUDY KARSCH 10 CFR SECTION: CDEF 21.21(b)(2) DEFECTS/NONCOMPLIANCE UNIT SCRAM RX INIT INITIAL MODE CURR CURRENT MODE CODE CRIT PWR PWR 1 N N 0 REFUELING 0 REFUELING ANCHOR DARLING 2" CHECK GLOBE VALVES DO NOT MEET MINIMUM FORWARD FLOW REQUIREMENTS AND EXHIBIT EXCESSIVE BACKSEAT LEAKAGE, THESE VALVES ARE USED IN CHARGING SAFETY INJECTION PUMP MINIFLOW LINES. THE FORWARD FLOW DEFICIENCY COULD CREATE A SUBSTANTIAL SAFETY HAZARD. THESE VALVES MAY ALSO BE USED IN SIMILAR APPLICATIONS AT OTHER NUCLEAR SITES.