Part 21 Report - 1995-192

ACCESSION #: 9509070043

                     Information & Support Services
                              P.O. Box 3707
                         Seattle, WA 98124-2207

          August 28, 1995
          G-1151-SJA-95-319

          Document Control Desk
          United States Nuclear Regulatory Commission
          Washington, D.C.  20555

BOEING    Reference: a)  Boeing Letter G-1151-RSO-92-365 dated August 20,
                         1992; R. S. Orr to the NRC Operations Center

                    b)   NRC Letter Docket No. 99901227 dated August 12,
                         1992; L. J. Norrholm to R. S. Orr; Subject:
                         Response to 10 CFR 21 Inquiry

          Dear Sir or Madam:

          In accordance with the reference correspondence and 10 CFR 21,
          Boeing is sending the NRC the attached error notice(s) received
          from our former software suppliers.  Because of unknown current
          addresses, the following former customers were not notified:

               Reactor Controls, Inc.

               Echo Energy Consultants, Inc.

               Nuclear Applications and Systems Analysis Company (Japan)

               Nuclear Power Services

          Error notices have been sent to our other former customers.

          Very truly yours,

          Sandra J. Andrews
          Nuclear Administrator
          G-1151 M/S 7A-33
          (206) 865-6248

          Attachment(s): GTICES Program Report Forms Nos. 95.16, 95.17
          and 95.18

Georgia Tech             Computer Aided Structural Engineering Center

                         Georgia Institute of Technology
                         School of Civil & Environmental Engineering
                         Atlanta, Georgia 30332-0355
                         USA
                         404 o 894 o 2260
                         404 o 894 o 80141 FAX

                                                  AUG 28 1995
                                                  CONTRACTS

August 21, 1995

Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346

RE: GT STRUDL

Dear Sir or Madam:

Enclosed please find copies of GTICES PROGRAM REPORT FORMS Nos. 95.16
thru 95.18 and a VENDOR ACKNOWLEDGEMENT FORM.  Please sign and return the
VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTICES Program
Report.

Thank you for reviewing the Program Report and for returning the
Acknowledgement Form.

Best regards,
CASE Center

Catherine Lee
Configuration Control Manager

CL/jhb
Enclosures

                      GTSTRUDL Program Report Form

                                        GPRF No.: 95.16

                                        DATE: August 21, 1995

FROM:     Computer-Aided Structural Engineering Center
          Georgia Institute of Technology
          Atlanta, Georgia 30332-0355

SEVERITY LEVEL:

_ URGENT       Problem results in incorrect answers which may not be
               apparent or job aborts and cannot be recovered within the
               session or job.

_ SERIOUS      Problem results in incorrect answers which are obvious or
               problem prevents completion of a particular user's task.

_ MINOR        Problem can be worked around or problem poses high
               frustration factor.

x INFORMATIVE  Documentation error, program usage tip, user
               inconveniences.

Date Problem Confirmed   August 21, 1995

Date Notification Sent    August 23, 1995

Computers      VAX, PC

Operating System    VMS, DOS

Version   9301 VAX, 9401 VAX and 9401 PC

Target Release for Correction      95.01


                                   Configuration Control Manager
Signature                          Title
R & D Division

Catherine Lee                      August 21, 1995
Typed or Printed Name              Date of Signature

Signature                          Title
Professional Services Division

Typed or Printed Name              Date of Signature

                                                                 Rev. 2.2

                      GTSTRUDL Program Report Form
                               (Continued)

                                                  GPRF No.: 95.16

                                                  DATE: August 21, 1995

DESCRIPTION:

     For 9301 VAX, 9401 VAX and 9401 PC Verification Manual, there is a
typo in section 1.8 "Frame Analysis Verification Problem #8".  In Table
1.8-1 "Comparison for Verification Problem #8", on page 1.8-3, the Moment
x reaction at joint 1 (M sub 1x,) for GTSTRUDL result should be "-227.413
k-in" instead of "227.413 k-in".

                                                                 Rev. 2.2

                      GTSTRUDL Program Report Form

                                                  GPRF No.: 95.17

                                                  DATE: August 21, 1995

FROM:     Computer-Aided Structural Engineering Center
          Georgia Institute of Technology
          Atlanta, Georgia 30332-0355

SEVERITY LEVEL:

x URGENT       Problem results in incorrect answers which may not be
               apparent or job aborts and cannot be recovered within the
               session or job.

_ SERIOUS      Problem results in incorrect answers which are obvious or
               problem prevents completion of a particular user's task.

_ MINOR        Problem can be worked around or problem poses high
               frustration factor.

_ INFORMATIVE  Documentation error, program usage tip, user
               inconveniences.

Date Problem Confirmed   August 21, 1995

Date Notification Sent   August 23, 1995

Computers      All

Operating System    All

Version   9001 thru 9501

Target Release for Correction 9601

                                   Director
Signature                          Title
R & D Division

Kenneth Will                       August 21, 1995
Typed or Printed Name              Date of Signature

Signature                          Title
Professional Services Division

Typed or Printed Name              Date of Signature

                                                                 Rev. 2.2

                      GTSTRUDL Program Report Form
                               (Continued)

                                                  GPRF No.: 95.17

                                                  DATE: August 21, 1995

DESCRIPTION:

Linear varying LINE LOADS created in GTModeler for elements which have
midside nodes on the loaded edge (IPQQ, IPQLQ4, IPQLQ1, IPQLQ2, IPQLQ2B,
IPQLQ3) are translated into GTSTRUDL incorrectly and also generated
incorrectly if the GENERATE INPUT file menu is picked.  The incorrectly
translated linear varying loads may be verified using the LIST SUM
REACTIONS command after a STIFFNESS ANALYSIS or by returning to GTModeler
and using the DISPLAY LOAD menu.  Note that the loads will appear to have
been generated correctly if they are displayed using DISPLAY LOAD before
returning to Command Mode or generating an input file.

Workaround:

Do not use GTMODELER to create linear varying LINE LOADS for elements
which contain midside nodes.  Return to command mode and using the
ELEMENT LOAD command to specify EDGE FORCES.

Applicable Section of the Documentation:

GTMODELER - Volume 6 of the GTSTRUDL Users Manual

LINE LOADS     -    Section 11.2
DISPLAY LOAD   -    Section 6.5

Volume 3 of the GTSTRUDL Users Manual

EDGE FORCES for Isoparametric Elements  -    Section 2.3.5.4.2.1

                                                                 Rev. 2.2

                      GTSTRUDL Program Report Form

                                                  GPRF No.: 95.18

                                                  DATE: August 21, 1995

FROM:     Computer-Aided Structural Engineering Center
          Georgia Institute of Technology
          Atlanta, Georgia 30332-0355

SEVERITY LEVEL:

x URGENT  Problem results in incorrect answers which may not be apparent
          or job aborts and cannot be recovered within the session or
          job.

_ SERIOUS Problem results in incorrect answers which are obvious or
          problem prevents completion of a particular user's task.

_ MINOR   Problem can be worked around or problem poses high frustration
          factor.

_ INFORM- Documentation error, program usage tip, user
  ATIVE   inconveniences.

Date Problem Confirmed   August 21, 1995

Date Notification Sent   August 23, 1995

Computers      All

Operating System    All

Version 9001 thru 9501

Target Release for Correction 9601

                                   Director, R&D
Signature                          Title
R & D Division

Kenneth Will                       August 21, 1995
Typed or Printed Name              Date of Signature

Signature                          Title
Professional Services Division

Typed or Printed Name              Date of Signature

                                                                 Rev. 2.2

                      GTSTRUDL Program Report Form
                               (Continued)

                                                  GPRF No.: 95.18

                                                  DATE: August 21, 1995

DESCRIPTION:

INERTIA LOADS (self-weight) created in GTModeler for the TRANS3D
TRIDIMENSIONAL element are incorrect.  The error may be verified using
the DISPLAY LOAD menu or the CHECK MODEL menu using the CHK LD SUM menu
pick.  The LIST SUM REACTIONS command may also be used after a STIFFNESS
ANALYSIS to verify that the reactions are incorrect.

Workaround:

Do not use GTMODELER to create INERTIA LOADS if the model contains
TRANS3D elements.  Return to command mode and using the ELEMENT LOAD
command to specify BODY FORCES for all the elements in the model.

Applicable Section of the Documentation:

GTMODELER - Volume 6 of the GTSTRUDL Users Manual

INERTIA LOADS -     Section 11.1
DISPLAY LOAD  -     Section 6.5
CHECK MODEL   -     Section 14

Volume 3 of the GTSTRUDL Users Manual

BODY FORCES for Isoparametric Elements  -    Section 2.3.5.4.2.3

                                                                Rev.  2.2

*** END OF DOCUMENT ***