Part 21 Report - 1995-042
LICENSEE: VIRGINIA POWER CO.
SITE: NORTH ANNA 1 2 EN NUMBER:28331
DOCKET: 05000338 05000339 EVENT DATE: 02-03-95
RX TYPE: PWR PWR EVENT TIME: 14:30
VENDORS: W-3-LP W-3-LP NOTIFY DATE: 02-03-95
EMERGENCY CLASS: N/A REGION: 2 STATE: VA TIME: 15:15
OPS OFFICER: JOSEPH SEBROSKY
10 CFR SECTION: AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS
NLCO TECH SPEC LCO A/S
UNIT SCRAM RX INIT INITIAL MODE CURR CURRENT MODE
CODE CRIT PWR PWR
1 N Y 100 POWER OPERATION 100 POWER OPERATION
2 N Y 91 POWER OPERATION 91 POWER OPERATION
SOLID STATE PROTECTION SYSTEM (SSPS) DECLARED INOPERABLE FOR BOTH
UNITS.
AT 14:30 THE LICENSEE DECLARED THE SSPS INOPERABLE ON BOTH UNITS.
THE REASON THE SSPS WERE DECLARED INOPERABLE IS BECAUSE A STEAM
BREAK COULD CAUSE A SHORT IN THE TURBINE TRIP PROTECTION CIRCUITS
LEADING TO A LOSS OF POWER TO BOTH TRAINS OF THE SSPS. THE
POSTULATED EVENT IS SIMILAR TO THAT REPORTED BY DIABLO CANYON ON
2/1/95 (SEE EVENT #28318).
THE LICENSEE HAS ENTERED TECHNICAL SPECIFICATION LIMITING
CONDITION FOR OPERATION ACTION STATEMENTS 3.3.1.1 FOR THE REACTOR
TRIP PROTECTION SYSTEM, 3.3.2.1 FOR THE ESF SYSTEM, AND 3.0.3 DUE
TO DECLARING SSPS INOPERABLE. THE LIMITING TECH SPEC IS 3.3.2.1
WHICH REQUIRES THE LICENSEE TO BE IN HOT STANDBY WITHIN 6 HOURS
AND TO BE IN HOT SHUTDOWN WITHIN 30 HOURS.
THE LICENSEE WILL INFORM THE RESIDENT INSPECTOR.