The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Part 21 Report - 1995-042

LICENSEE: VIRGINIA POWER CO.
SITE: NORTH ANNA 1 2                        EN NUMBER:28331
DOCKET: 05000338 05000339                EVENT DATE: 02-03-95
RX TYPE: PWR PWR                         EVENT TIME: 14:30
VENDORS: W-3-LP W-3-LP                  NOTIFY DATE: 02-03-95
EMERGENCY CLASS: N/A  REGION: 2 STATE: VA      TIME: 15:15
OPS OFFICER: JOSEPH SEBROSKY
10 CFR SECTION: AOUT  50.72(b)(1)(ii)(B)  OUTSIDE DESIGN BASIS
                NLCO                      TECH SPEC LCO A/S
UNIT  SCRAM   RX   INIT  INITIAL MODE     CURR   CURRENT MODE
      CODE   CRIT  PWR                    PWR
 1    N       Y    100   POWER OPERATION  100   POWER OPERATION
 2    N       Y     91   POWER OPERATION   91   POWER OPERATION

SOLID STATE PROTECTION SYSTEM (SSPS) DECLARED INOPERABLE FOR BOTH
UNITS.
                                                                 
AT 14:30 THE LICENSEE DECLARED THE SSPS INOPERABLE ON BOTH UNITS.
 THE REASON THE SSPS WERE DECLARED INOPERABLE IS BECAUSE A STEAM
BREAK COULD CAUSE A SHORT IN THE TURBINE TRIP PROTECTION CIRCUITS
LEADING TO A LOSS OF POWER TO BOTH TRAINS OF THE SSPS.  THE
POSTULATED EVENT IS SIMILAR TO THAT REPORTED BY DIABLO CANYON ON
2/1/95 (SEE EVENT #28318).
                                                                 
THE LICENSEE HAS ENTERED TECHNICAL SPECIFICATION LIMITING
CONDITION FOR OPERATION ACTION STATEMENTS 3.3.1.1 FOR THE REACTOR
TRIP PROTECTION SYSTEM, 3.3.2.1 FOR THE ESF SYSTEM, AND 3.0.3 DUE
TO DECLARING SSPS INOPERABLE. THE LIMITING TECH SPEC IS 3.3.2.1
WHICH REQUIRES THE LICENSEE TO BE IN HOT STANDBY WITHIN 6 HOURS
AND TO BE IN HOT SHUTDOWN WITHIN 30 HOURS.
                                                                 
THE LICENSEE WILL INFORM THE RESIDENT INSPECTOR.