Event Notification Report for November 05, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/04/2025 - 11/05/2025

EVENT NUMBERS
580265802758034
Power Reactor
Event Number: 58026
Facility: Wolf Creek
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: Michael Payne
HQ OPS Officer: Ernest West
Notification Date: 11/05/2025
Notification Time: 16:44 [ET]
Event Date: 11/05/2025
Event Time: 10:03 [CST]
Last Update Date: 11/05/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Vossmar, Patricia (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
AUTOMATIC EMERGENCY DIESEL GENERATOR ACTUATION

The following information was provided by the licensee via phone and email:

"At 1003 Central Standard Time (CST), with [Unit 1] in mode 5 at 0 percent power, an actuation of the 'A' emergency diesel generator (EDG) occurred when energizing main transformers from the switchyard for post-installation soak. The energization was coordinated with transmission system operators using approved procedures, however, grid conditions external to the substation allowed the voltage to drop below the NB01 undervoltage relay setpoint. The EDG automatically started as designed and picked up the loads on the NB01 bus. All safety systems responded as designed. Substation parameters immediately recovered to normal values, and all systems were restored to [normal] standby conditions.

"This event is being reported in accordance with 10 CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the 'A' EDG. There was no impact on the health and safety of the public or plant personnel.

"The NRC Resident Inspector has been notified."


Independent Spent Fuel Storage Installation
Event Number: 58027
Rep Org: San Onofre
Licensee: Southern California Edison Company
Region: 4
City: San Clemente   State: CA
County: San Diego
License #: GL
Agreement: Y
Docket: 72-41
NRC Notified By: Kevin Bryan
HQ OPS Officer: Ernest West
Notification Date: 11/05/2025
Notification Time: 16:58 [ET]
Event Date: 11/05/2025
Event Time: 11:09 [PST]
Last Update Date: 11/05/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
Vossmar, Patricia (R4DO)
Event Text
OFFSITE NOTIFICATION

The following information was provided by San Onofre Nuclear Generating Station (SONGS) via phone and email:

"At 1109 PST, SONGS made [an] official notification to the [California] Department of Toxic Substance Control (DTSC) relating to one violation/citation non-minor, requiring corrective action related to the hazardous waste facility, permit CAD000630921.

"Specifically, SONGS violated 22 California Code of Regulations (CCR) 66270.30(a) and California Health and Safety Code 25202(a), in that SONGS failed to comply with the conditions of the permit, specifically Part V `Special Conditions,' #5. To wit, DTSC inspectors observed the secondary containment which failed to be free of cracks or gaps in a waste management unit located in the [Hazardous Materials] Area - South Yard Facility (SYF), Section A.

"During the physical inspection, the inspector noted holes were drilled into the slab (the containment system) of mixed waste/hazmat storage pad areas.

"Because the identified holes only partially penetrate the secondary containment (i.e., the concrete pad), the secondary containment remains functional and intact and is sufficiently impervious to contain leaks, spills and accumulated precipitation.

"SONGS is in discussions with DTSC to determine if the holes partially penetrating the pad exceed the permit requirement."

The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

SONGS will notify NRC Region IV of this event.


Agreement State
Event Number: 58034
Rep Org: Colorado Dept of Health
Licensee: Deck Superstore
Region: 4
City: Commerce City   State: CO
County:
License #: GL002143
Agreement: Y
Docket:
NRC Notified By: Kathryn Kirk
HQ OPS Officer: Adam Koziol
Notification Date: 11/10/2025
Notification Time: 17:47 [ET]
Event Date: 11/05/2025
Event Time: 00:00 [MST]
Last Update Date: 11/10/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST EXIT SIGNS

The following is a summary of information provided by the Colorado Department of Public Health and Environment via email:

The licensee reported two exit signs, each containing 6.0 Ci of tritium, were lost in Commerce City, Colorado.

Manufacturer: Isolite Corporation
Model Number: SLX60

Colorado Event Number: CO250042

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf