Event Notification Report for January 01, 2021
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/31/2020 - 01/01/2021
Agreement State
Event Number: 55043
Rep Org: PA BUREAU OF RADIATION PROTECTION
Licensee: RSL (USA) Inc.
Region: 1
City: Wilkes-Barre State: PA
County:
License #: PA-0892
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Andrew Waugh
Licensee: RSL (USA) Inc.
Region: 1
City: Wilkes-Barre State: PA
County:
License #: PA-0892
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Andrew Waugh
Notification Date: 12/23/2020
Notification Time: 11:30 [ET]
Event Date: 12/10/2020
Event Time: 11:50 [EST]
Last Update Date: 12/23/2020
Notification Time: 11:30 [ET]
Event Date: 12/10/2020
Event Time: 11:50 [EST]
Last Update Date: 12/23/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
ELISE BURKET (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ELISE BURKET (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - LOST AND RECOVERED RADIOACTIVE MATERIAL
The following information was received via email:
"On December 10, 2020, the licensee discovered a lost iodine-131 shipment. The shipper of the 475 mCi of iodine-131 Liquid (Yellow II label) delivered the package to the wrong address, a neighboring business. The package was delivered to the licensee by the recipient before the package was known to be 'lost', later on the scheduled delivery date. The surface reading of 12 mR/hr was obtained upon the licensee receiving the package. The package was estimated to be in the possession of the recipient for approximately 1 hour. The estimated dose was approximately 12 mrem if an individual had been in contact with the package for the entire time it was in the possession of the recipient. Since the material was delivered by the recipient within the time frame the shipper would normally deliver, and the facility had no reason to suspect the material was incorrectly delivered, the licensee will inform the shipper of the incident to handle training of their staff on proper delivery of radioactive packages."
PA Event Report ID No.: PA200024
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received via email:
"On December 10, 2020, the licensee discovered a lost iodine-131 shipment. The shipper of the 475 mCi of iodine-131 Liquid (Yellow II label) delivered the package to the wrong address, a neighboring business. The package was delivered to the licensee by the recipient before the package was known to be 'lost', later on the scheduled delivery date. The surface reading of 12 mR/hr was obtained upon the licensee receiving the package. The package was estimated to be in the possession of the recipient for approximately 1 hour. The estimated dose was approximately 12 mrem if an individual had been in contact with the package for the entire time it was in the possession of the recipient. Since the material was delivered by the recipient within the time frame the shipper would normally deliver, and the facility had no reason to suspect the material was incorrectly delivered, the licensee will inform the shipper of the incident to handle training of their staff on proper delivery of radioactive packages."
PA Event Report ID No.: PA200024
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55044
Rep Org: WISCONSIN RADIATION PROTECTION
Licensee: Amcor
Region: 3
City: Madison State: WI
County:
License #: GL 709058
Agreement: Y
Docket:
NRC Notified By: Megan Shober
HQ OPS Officer: Andrew Waugh
Licensee: Amcor
Region: 3
City: Madison State: WI
County:
License #: GL 709058
Agreement: Y
Docket:
NRC Notified By: Megan Shober
HQ OPS Officer: Andrew Waugh
Notification Date: 12/23/2020
Notification Time: 11:49 [ET]
Event Date: 12/22/2020
Event Time: 00:00 [CST]
Last Update Date: 12/23/2020
Notification Time: 11:49 [ET]
Event Date: 12/22/2020
Event Time: 00:00 [CST]
Last Update Date: 12/23/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
JAMNES CAMERON (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
- CNSC (CANADA) (EMAIL)
JAMNES CAMERON (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
- CNSC (CANADA) (EMAIL)
AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGNS
The following information was received via email:
"The Department [Wisconsin Radiation Protection Section] was notified on December 22, 2020, of the loss of four Safety Light Corporation Model SLX-60 tritium exit signs. The signs each contained 7.5 Ci of tritium in December 2006. The licensee searched for the missing signs and was unable to locate them on the premises. The licensee believes that the signs were inadvertently disposed during construction in 2019. The Department will follow up with the licensee."
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received via email:
"The Department [Wisconsin Radiation Protection Section] was notified on December 22, 2020, of the loss of four Safety Light Corporation Model SLX-60 tritium exit signs. The signs each contained 7.5 Ci of tritium in December 2006. The licensee searched for the missing signs and was unable to locate them on the premises. The licensee believes that the signs were inadvertently disposed during construction in 2019. The Department will follow up with the licensee."
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Non-Agreement State
Event Number: 55045
Rep Org: Avera McKennan Nuclear Medicine
Licensee: Avera McKennan Nuclear Medicine
Region: 4
City: Sioux Falls State: SD
County:
License #: 40-16571-02
Agreement: N
Docket:
NRC Notified By: Michelle White
HQ OPS Officer: Andrew Waugh
Licensee: Avera McKennan Nuclear Medicine
Region: 4
City: Sioux Falls State: SD
County:
License #: 40-16571-02
Agreement: N
Docket:
NRC Notified By: Michelle White
HQ OPS Officer: Andrew Waugh
Notification Date: 12/23/2020
Notification Time: 12:12 [ET]
Event Date: 12/15/2020
Event Time: 13:00 [MST]
Last Update Date: 12/23/2020
Notification Time: 12:12 [ET]
Event Date: 12/15/2020
Event Time: 13:00 [MST]
Last Update Date: 12/23/2020
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
10 CFR Section:
35.3045(a)(1) - Dose <> Prescribed Dosage
Person (Organization):
JEREMY GROOM (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
JEREMY GROOM (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
PATIENT RECEIVED THE WRONG RADIONUCLIDE DURING TREATMENT
A patient was set to receive an I-123 scan and uptake procedure on 12/15/20. Due to an error in scheduling the patient incorrectly underwent an I-131 therapy procedure instead. The I-131 therapy procedure delivered 15.8 mCi to the patient's thyroid where an I-123 scan and uptake procedure would have only delivered microCuries to the patient's thyroid.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
A patient was set to receive an I-123 scan and uptake procedure on 12/15/20. Due to an error in scheduling the patient incorrectly underwent an I-131 therapy procedure instead. The I-131 therapy procedure delivered 15.8 mCi to the patient's thyroid where an I-123 scan and uptake procedure would have only delivered microCuries to the patient's thyroid.
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 55047
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: ABI Engineering, Inc.
Region: 4
City: Santa Ana State: CA
County:
License #: 7945-30
Agreement: Y
Docket:
NRC Notified By: L. Robert Greger
HQ OPS Officer: Andrew Waugh
Licensee: ABI Engineering, Inc.
Region: 4
City: Santa Ana State: CA
County:
License #: 7945-30
Agreement: Y
Docket:
NRC Notified By: L. Robert Greger
HQ OPS Officer: Andrew Waugh
Notification Date: 12/23/2020
Notification Time: 20:46 [ET]
Event Date: 12/23/2020
Event Time: 00:00 [PST]
Last Update Date: 12/23/2020
Notification Time: 20:46 [ET]
Event Date: 12/23/2020
Event Time: 00:00 [PST]
Last Update Date: 12/23/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
JEREMY GROOM (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
JEREMY GROOM (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - LOST THEN FOUND MOISTURE / DENSITY GAUGE
The following information was received via email:
"On December 23, 2020, the Radiation Safety Officer (RSO) for ABI Engineering, Inc. contacted the California Department of Public Health - Radiologic Health Branch to report a moisture density gauge that was lost while transporting the gauge from the worksite in Orange, CA to the office. The gauge was locked in the transport case and placed in the vehicle, a pickup truck with a camper shell. During the short trip back to the office, the driver of another vehicle alerted the licensee's operator that the rear door of the camper shell was open. The licensee's operator then discovered that the gauge was missing, with one end of the chain used to secure the transport case loose. The licensee's operator backtracked to the jobsite in an attempt to find the gauge but did not locate it. The driver then notified the RSO and went to file a police report. Approximately 20-30 minutes after the RSO reported the incident to the Radiologic Health Branch, the RSO received a call from an individual who found the gauge. The gauge will be returned to the licensee. The gauge is a CPN International MC-3 (10 mCi Cs-137, 50 mCi Am-241:Be), S/N M39048766. The licensee's investigation into this event is ongoing and will be reviewed further by the California Department of Public Health."
California 5010 Number: 122320
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following information was received via email:
"On December 23, 2020, the Radiation Safety Officer (RSO) for ABI Engineering, Inc. contacted the California Department of Public Health - Radiologic Health Branch to report a moisture density gauge that was lost while transporting the gauge from the worksite in Orange, CA to the office. The gauge was locked in the transport case and placed in the vehicle, a pickup truck with a camper shell. During the short trip back to the office, the driver of another vehicle alerted the licensee's operator that the rear door of the camper shell was open. The licensee's operator then discovered that the gauge was missing, with one end of the chain used to secure the transport case loose. The licensee's operator backtracked to the jobsite in an attempt to find the gauge but did not locate it. The driver then notified the RSO and went to file a police report. Approximately 20-30 minutes after the RSO reported the incident to the Radiologic Health Branch, the RSO received a call from an individual who found the gauge. The gauge will be returned to the licensee. The gauge is a CPN International MC-3 (10 mCi Cs-137, 50 mCi Am-241:Be), S/N M39048766. The licensee's investigation into this event is ongoing and will be reviewed further by the California Department of Public Health."
California 5010 Number: 122320
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Agreement State
Event Number: 55048
Rep Org: PA BUREAU OF RADIATION PROTECTION
Licensee: RLS (USA) Inc
Region: 1
City: Trevose State: PA
County:
License #: PA-0515
Agreement: Y
Docket:
NRC Notified By: Joshua Myers
HQ OPS Officer: Thomas Kendzia
Licensee: RLS (USA) Inc
Region: 1
City: Trevose State: PA
County:
License #: PA-0515
Agreement: Y
Docket:
NRC Notified By: Joshua Myers
HQ OPS Officer: Thomas Kendzia
Notification Date: 12/24/2020
Notification Time: 08:59 [ET]
Event Date: 12/23/2020
Event Time: 00:00 [EST]
Last Update Date: 12/24/2020
Notification Time: 08:59 [ET]
Event Date: 12/23/2020
Event Time: 00:00 [EST]
Last Update Date: 12/24/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
ELISE BURKET (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ELISE BURKET (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - TRANSPORTATION ACCIDENT DAMAGING LICENSED MATERIAL
The following information was received from the Pennsylvania Department of Environmental Protection via email:
"On December 23, 2020 the New Jersey Department of Environmental Protection reported to the Pennsylvania Department of Environmental Protection that a licensee's courier had been involved in a fatal vehicle accident. [The New Jersey Emergency Response and Radiation Protection Programs responded to the incident scene.] The vehicle was carrying nine packages of Technetium-99m, one of which was ripped open releasing two syringe pigs into the interior of the vehicle. One of those two had been used by a customer and shattered during the accident. The other of those two remained intact and was labeled 27mCi of Tc99m Sestamibi calibrated on 12/21/2020 at 1130am. The remaining eight packaged were intact and had background radiation readings. The vehicle was surveyed, and no contamination was found. The material was picked up the licensee RSO and safely returned to its destination. The Department will continue to gather information and provide updates when available."
This event was also reported on National Response Center Incident Report # 1294881.
PA Event Report ID No.: PA200024
The following information was received from the Pennsylvania Department of Environmental Protection via email:
"On December 23, 2020 the New Jersey Department of Environmental Protection reported to the Pennsylvania Department of Environmental Protection that a licensee's courier had been involved in a fatal vehicle accident. [The New Jersey Emergency Response and Radiation Protection Programs responded to the incident scene.] The vehicle was carrying nine packages of Technetium-99m, one of which was ripped open releasing two syringe pigs into the interior of the vehicle. One of those two had been used by a customer and shattered during the accident. The other of those two remained intact and was labeled 27mCi of Tc99m Sestamibi calibrated on 12/21/2020 at 1130am. The remaining eight packaged were intact and had background radiation readings. The vehicle was surveyed, and no contamination was found. The material was picked up the licensee RSO and safely returned to its destination. The Department will continue to gather information and provide updates when available."
This event was also reported on National Response Center Incident Report # 1294881.
PA Event Report ID No.: PA200024
Power Reactor
Event Number: 55053
Facility: South Texas
Region: 4 State: TX
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: David Wurtz
HQ OPS Officer: Howie Crouch
Region: 4 State: TX
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: David Wurtz
HQ OPS Officer: Howie Crouch
Notification Date: 12/30/2020
Notification Time: 20:30 [ET]
Event Date: 12/30/2020
Event Time: 15:50 [CST]
Last Update Date: 12/30/2020
Notification Time: 20:30 [ET]
Event Date: 12/30/2020
Event Time: 15:50 [CST]
Last Update Date: 12/30/2020
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
WERNER, GREG (R4)
WERNER, GREG (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION DUE TO INADVERTENT EMERGENCY SIREN ACTIVATION
"On December 30, 2020 at 1550 CST, South Texas Project (STP) received a report that two Emergency Notification System sirens inadvertently actuated. The sirens were heard by residents in the area who contacted the Matagorda County Sheriff's office, which notified the Emergency Response Division at STP of the siren actuation at 1557 CST.
"Both sirens were initially restored, however siren #24 subsequently actuated again at 1735 CST. Siren #24 has been disconnected. Siren #27 remains available. Thirty-one of thirty-two sirens are available.
"This notification is being made under 10CFR50.72(b)(2)(xi) as an event where other government agencies were notified. The sirens are no longer alarming. A social media release is planned.
"The NRC Resident Inspector has been notified of the event."
The licensee believes the sirens actuated due to significant rain in the area but will be investigating the cause of the inadvertent actuation.
"On December 30, 2020 at 1550 CST, South Texas Project (STP) received a report that two Emergency Notification System sirens inadvertently actuated. The sirens were heard by residents in the area who contacted the Matagorda County Sheriff's office, which notified the Emergency Response Division at STP of the siren actuation at 1557 CST.
"Both sirens were initially restored, however siren #24 subsequently actuated again at 1735 CST. Siren #24 has been disconnected. Siren #27 remains available. Thirty-one of thirty-two sirens are available.
"This notification is being made under 10CFR50.72(b)(2)(xi) as an event where other government agencies were notified. The sirens are no longer alarming. A social media release is planned.
"The NRC Resident Inspector has been notified of the event."
The licensee believes the sirens actuated due to significant rain in the area but will be investigating the cause of the inadvertent actuation.
Agreement State
Event Number: 55050
Rep Org: OHIO BUREAU OF RADIATION PROTECTION
Licensee: Shasta Beverages, Incorporated
Region: 3
City: Obetz State: OH
County:
License #: 00006GL0210
Agreement: Y
Docket:
NRC Notified By: Michael Snee
HQ OPS Officer: Ossy Font
Licensee: Shasta Beverages, Incorporated
Region: 3
City: Obetz State: OH
County:
License #: 00006GL0210
Agreement: Y
Docket:
NRC Notified By: Michael Snee
HQ OPS Officer: Ossy Font
Notification Date: 12/28/2020
Notification Time: 11:20 [ET]
Event Date: 05/28/2020
Event Time: 00:00 [EST]
Last Update Date: 12/28/2020
Notification Time: 11:20 [ET]
Event Date: 05/28/2020
Event Time: 00:00 [EST]
Last Update Date: 12/28/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
CAMERON, JAMNES (R3)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
CAMERON, JAMNES (R3)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
AGREEMENT STATE REPORT - LOST GAUGE
The following was received from the Ohio Department of Health via email:
"While conducting the annual General License inventory, the licensee discovered a missing gauge. Attempts to locate the gauge were not successful. It is believed that gauge was inadvertently sent to a metal scrap yard. The gauge is an Industrial Dynamics Model FT-50 [(s/n: 116107)] containing a 100 mCi Am-241 sealed source."
Ohio Item Number: OH 2020-058
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following was received from the Ohio Department of Health via email:
"While conducting the annual General License inventory, the licensee discovered a missing gauge. Attempts to locate the gauge were not successful. It is believed that gauge was inadvertently sent to a metal scrap yard. The gauge is an Industrial Dynamics Model FT-50 [(s/n: 116107)] containing a 100 mCi Am-241 sealed source."
Ohio Item Number: OH 2020-058
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 55055
Facility: Vogtle
Region: 2 State: GA
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Jamaal Merriweather
HQ OPS Officer: Lloyd Desotell
Region: 2 State: GA
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Jamaal Merriweather
HQ OPS Officer: Lloyd Desotell
Notification Date: 01/03/2021
Notification Time: 08:33 [ET]
Event Date: 01/03/2021
Event Time: 06:45 [EST]
Last Update Date: 01/03/2021
Notification Time: 08:33 [ET]
Event Date: 01/03/2021
Event Time: 06:45 [EST]
Last Update Date: 01/03/2021
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(xiii) - Loss Comm/Asmt/Response
10 CFR Section:
50.72(b)(3)(xiii) - Loss Comm/Asmt/Response
Person (Organization):
MARK MILLER (R2DO)
MARK MILLER (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
NONFUNCTIONAL SEISMIC MONITORING SYSTEM
"At 1414 EST on 12/31/2020, a planned maintenance outage commenced on the Vogtle 1and 2 Seismic Monitoring System. The work was to address abnormal indications on the uninterruptable power supply, and was scheduled for an eight (8) hour duration. During the restoration activities, the system did not respond properly and has remained Non-Functional. Compensatory measures for seismic event classification were implemented in accordance with Vogtle procedures prior to removing the system from service. Based upon the troubleshooting conducted, the system is not expected to be restored within 72 hours from the start of the planned outage."
"This is an eight-hour, non-emergency notification for a loss of Emergency Assessment Capability. This event is reportable in accordance with 10 CFR 50.72(b)(3)(xiii) because the Seismic Monitoring System is the method for evaluating that an Operational Basis Earthquake (OBE) threshold has been exceeded following a seismic event in accordance with Initiating Condition 'Seismic event greater than OBE levels' and Emergency Action Level HU2. There was no impact on the health and safety of the public or plant personnel. "
"The NRC Resident Inspector has been notified."
Compensatory measures implemented include having a phone number to call to verify if an earthquake has occurred.
"At 1414 EST on 12/31/2020, a planned maintenance outage commenced on the Vogtle 1and 2 Seismic Monitoring System. The work was to address abnormal indications on the uninterruptable power supply, and was scheduled for an eight (8) hour duration. During the restoration activities, the system did not respond properly and has remained Non-Functional. Compensatory measures for seismic event classification were implemented in accordance with Vogtle procedures prior to removing the system from service. Based upon the troubleshooting conducted, the system is not expected to be restored within 72 hours from the start of the planned outage."
"This is an eight-hour, non-emergency notification for a loss of Emergency Assessment Capability. This event is reportable in accordance with 10 CFR 50.72(b)(3)(xiii) because the Seismic Monitoring System is the method for evaluating that an Operational Basis Earthquake (OBE) threshold has been exceeded following a seismic event in accordance with Initiating Condition 'Seismic event greater than OBE levels' and Emergency Action Level HU2. There was no impact on the health and safety of the public or plant personnel. "
"The NRC Resident Inspector has been notified."
Compensatory measures implemented include having a phone number to call to verify if an earthquake has occurred.