Event Notification Report for July 05, 2020
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
07/04/2020 - 07/05/2020
EVENT NUMBERS
54762
54762
Power Reactor
Event Number: 54762
Facility: Turkey Point
Region: 2 State: FL
Unit: [] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Arturo Alvarez
HQ OPS Officer: Jeffrey Whited
Region: 2 State: FL
Unit: [] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: Arturo Alvarez
HQ OPS Officer: Jeffrey Whited
Notification Date: 07/05/2020
Notification Time: 23:05 [ET]
Event Date: 07/05/2020
Event Time: 21:09 [EDT]
Last Update Date: 07/05/2020
Notification Time: 23:05 [ET]
Event Date: 07/05/2020
Event Time: 21:09 [EDT]
Last Update Date: 07/05/2020
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
MARK MILLER (R2DO)
MARK MILLER (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 4 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
REACTOR TRIP DUE TO TURBINE TRIP
"Reactor trip caused by turbine trip due to voltage regulator issues. Plant is stable. Exited the Emergency Operating Procedure Network."
Auxiliary Feedwater automatically actuated and was subsequently restored to standby.
The licensee notified the NRC Resident Inspector.
"Reactor trip caused by turbine trip due to voltage regulator issues. Plant is stable. Exited the Emergency Operating Procedure Network."
Auxiliary Feedwater automatically actuated and was subsequently restored to standby.
The licensee notified the NRC Resident Inspector.