The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for July 16, 2003






                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           07/15/2003 - 07/16/2003



                              ** EVENT NUMBERS **



39854  39987  39989  39996  39997  39998  



!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!

+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39854       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: HARRIS                   REGION:  2  |NOTIFICATION DATE: 05/16/2003|

|    UNIT:  [1] [] []                 STATE:  NC |NOTIFICATION TIME: 12:53[EDT]|

|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        05/16/2003|

+------------------------------------------------+EVENT TIME:        04:56[EDT]|

| NRC NOTIFIED BY:  JOHN YADUSKY                 |LAST UPDATE DATE:  07/15/2003|

|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |ROBERT HAAG          R2      |

|10 CFR SECTION:                                 |                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Hot Standby      |0        Hot Standby      |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| SPECIFIED SYSTEM ACTUATION                                                   |

|                                                                              |

| "On 5/16/03 with the reactor shutdown in MODE 3, an unplanned actuation of   |

| Auxiliary Feedwater (AFW) system occurred during testing of the 'B' Main     |

| Feed Pump (MFP).  A trip of an uncoupled MFP generated a signal to start     |

| both motor-driven AFW pumps during testing following maintenance.  The 'A'   |

| motor-driven AFW pump was already in service, so the 'B' AFW pump started on |

| receipt of the signal.  Feed to the steam generators was always available,   |

| even without the additional actuation of the AFW system.  The purpose of the |

| actuation of AFW following a trip of the main feed system is to ensure       |

| adequate flow to the steam generator.  In this case, the main feed pump was  |

| being tested and was not being used to provide flow to the steam generator.  |

| Therefore the actuation was not required to provide any safety function.     |

| The 'B' motor-driven AFW pump was secured within approximately two minutes   |

| because the additional flow was not required.  This condition is being       |

| reported as an unplanned system actuation in accordance with 10 CFR          |

| 50.72(b)(3)(iv)(A).                                                          |

|                                                                              |

| "10 CFR 50.72 requires an 8-hour report for, 'Any event or condition that    |

| results in valid actuation of any of the systems listed in paragraph         |

| (b)(3)(iv)(B) of this section except when the actuation results from and is  |

| part of a pre-planned sequence during testing or reactor operation.'  In     |

| this case, the AFW pump start signal due to trip of the last running MFP is  |

| only applicable in MODES 1 and 2, and is not required in the current MODE of |

| plant operation (MODE 3).                                                    |

|                                                                              |

| "The NRC Resident Inspector was notified."                                   |

|                                                                              |

|                                                                              |

| * * * UPDATE ON 7/15/03 @ 1044 BY YADUSKY TO  LAURA * * *  RETRACTION        |

|                                                                              |

|                                                                              |

| Upon further evaluation, it has been determined that the reported event did  |

| not meet the definition of a valid signal. Therefore, the reporting          |

| criterion contained in 10 CFR 50.72(b)(3)(iv)(A) was not applicable.  Per    |

| NUREG 1022, Revision 2 (Event Reporting Guidelines 10 CFR 50.72 and 50.73),  |

| "Valid actuations are those actuations that result from `valid signals' . .  |

| . That are initiated in response to actual plant conditions or parameters    |

| satisfying the requirements for initiation of the safety function of the     |

| system."                                                                     |

|                                                                              |

| Because the AFW actuation signal was not initiated in response to an actual  |

| loss of the last running MFP (the motor was disconnected from the pump and   |

| no MFP was in operation), the actuation was not valid; therefore, the event  |

| is not reportable per 10 CFR 50.72(b)(3)(iv). In addition, because the       |

| invalid signal was received after the safety function had already been       |

| completed (the alternate train of AFW was operating at the time of the       |

| uncoupled motor trip), the event is not reportable per 10 CFR                |

| 50.73(a)(2)(iv)(A)(2)(ii).                                                   |

|                                                                              |

| The NRC Resident Inspector was notified.                                     |

|                                                                              |

| NRC notified REG 2 RDO.                                                      |

+------------------------------------------------------------------------------+



!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!

+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39987       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 07/10/2003|

|    UNIT:  [] [2] [3]                STATE:  IL |NOTIFICATION TIME: 04:03[EDT]|

|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        07/09/2003|

+------------------------------------------------+EVENT TIME:        22:00[CDT]|

| NRC NOTIFIED BY:  RON WIGGINS                  |LAST UPDATE DATE:  07/15/2003|

|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHRIS MILLER         R3      |

|10 CFR SECTION:                                 |                             |

|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          Y       99       Power Operation  |99       Power Operation  |

|3     N          Y       99       Power Operation  |99       Power Operation  |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| CONTROL ROOM HVAC REFRIGERATION AND CONDENSING UNIT TRIPPED DURING           |

| SURVEILLANCE TEST                                                            |

|                                                                              |

| "At 2200 hours on July 9, 2003, the B Control Room HVAC Refrigeration and    |

| Condensing Unit (RCU) tripped and would not stay running during surveillance |

| testing.  The RCU is a single train system and therefore is reportable per   |

| SAF 1.8 and LS-AA-1400, Event Reporting Guidelines Section 3.2.7.  The RCU   |

| is required to operate during a design basis accident to remove heat from    |

| the Main Control Room.  The Air Filtration Unit (AFU) of CREVS [Control Room |

| Emergency Ventilation System] remains operable.  This places both units in a |

| 30 day LCORA [Limiting Condition for Operation Required Action] per Tech     |

| Spec 3.7.5 Required Action A.1."                                             |

|                                                                              |

| The licensee has notified the NRC Resident Inspector.                        |

|                                                                              |

| * * * Retraction  on  07/15/03 at 1924 EDT by Dennis Francis taken by        |

| MacKinnon * * *                                                              |

|                                                                              |

| "On July 9, 2003, an ENS notification was made regarding the 'B' Control     |

| Room HVAC Refrigeration and Condensing Unit Inoperability.  The (event) was  |

| reported as a condition that would have prevent the fulfillment of a safety  |

| function.  However, after a review of the actual circumstances it was        |

| determined that the system did not trip as was believed at the time of the   |

| notification.  The system was thought to have tripped because a trip         |

| indicator light for the refrigeration compressor in the main control room    |

| was illuminated.  The breaker was inspected and no adverse condition         |

| observed.  Further investigation revealed that the trip indicator was        |

| illuminated due to the local control switch being in the AUTO-AFTER-START    |

| position.  Therefore when the compressor would not cycle off due to          |

| temperature, the trip indicator would illuminate.  Even though the condition |

| does not (affect) operability, it does indicate a false trip indication.     |

| Then normal position for this switch is AUTO-AFTER-STOP.  In this position   |

| the amber trip light indicator will not illuminate when the compressor turns |

| off to low temperature in the main control room.                             |

|                                                                              |

| "The switch position of AUTO-AFTER-START did not affect the ability of the   |

| system to perform its safety function. Therefore the ENS notification (Ref.  |

| EN # 39987) is being retracted."  NRC R3DO (RIEMER) notified.                |

|                                                                              |

| The NRC Resident Inspector will be notified of this retraction by the        |

| licensee.                                                                    |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39989       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  LOUISIANA RADIATION PROTECTION DIV   |NOTIFICATION DATE: 07/10/2003|

|LICENSEE:  MONSANTO CHEMICAL PLANT              |NOTIFICATION TIME: 18:55[EDT]|

|    CITY:  LULING                   REGION:  4  |EVENT DATE:        06/29/2003|

|  COUNTY:                            STATE:  LA |EVENT TIME:             [CDT]|

|LICENSE#:  LA-2216-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  07/11/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KRISS KENNEDY        R4      |

|                                                |SUSAN FRANT          NMSS    |

+------------------------------------------------+TIM MCGINTY          IRO     |

| NRC NOTIFIED BY:  MIKE HENRY                   |                             |

|  HQ OPS OFFICER:  BILL GOTT                    |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| PERSONNEL OVEREXPOSURE                                                       |

|                                                                              |

| Mike Henry from the Louisiana Department of Environmental Quality reported   |

| the potential personnel over-exposure due to a loss of control of a 1 Curie  |

| Cesium-137 source that came out of a damaged Berthold level gauge (Model #   |

| LB7442).  The event occurred at the Monsanto Chemical Plant in Luling, LA.   |

| The gauge was damaged on 06/29/03 causing the source to come out of its      |

| shield.  The source was then carried to a planner's desk where it remained   |

| until discovery on 07/10/03.  The owner of the desk spent approximately 50   |

| to 60 hours in the proximity of his desk during this time.  When the source  |

| was discovered, the building was evacuated and secured.  Medical personnel   |

| at Monsanto have contacted the Radiological Emergency Assistance Center, Oak |

| Ridge, TN.  Preliminarily, the licensee estimates that the planner may have  |

| received a whole body dose of 25 Rem and the person that carried the source  |

| may have received 1800 Rem to the hand.  Others may have also been exposed.  |

| No one has shown signs of sickness or erythema (redness of the skin).  A     |

| Berthold representative is scheduled to arrive on 07/11/03 to secure the     |

| source.  Mr. Henry will be traveling to the site to obtain additional        |

| information.  The State is not requesting NRC assistance at this time.       |

|                                                                              |

| A Commissioners' Assistants brief was held at 1900 EDT 07/10/03.             |

|                                                                              |

| * * * * UPDATE FROM MIKE HENRY TO NRC CONFERENCE CALL 1620 EDT ON 07/11/03   |

| * * * *                                                                      |

|                                                                              |

| Mr. Henry provided the following information based on his visit to the       |

| Monsanto plant this morning, 07/11/03.  A manufacturer's representative for  |

| Berthold arrived at the plant and retrieved the source around 0300 CDT       |

| 07/11/03.  Currently the source is in a shielded pig at the plant site.      |

|                                                                              |

| Blood tests were performed for seven individuals which were favorable with   |

| no cell changes noted.  These blood tests will be repeated periodically.  It |

| was determined that the planner who returned after days off to occupy the    |

| desk where the source had been previously left received 39.1 Rem over the    |

| calculated 44.7 hours that he occupied the desk during the 10-day period     |

| involved.  This determination was based on an analysis of his schedule and   |

| work habits and on the emissivity of the source.  Further dose calculations  |

| will be made.  The Monsanto company physician is in contact with REAC        |

| (Radiological Emergency Assistance Center) in Oak Ridge, TN and has          |

| requested their assistance in having a cytogenetic blood study performed for |

| the planner.                                                                 |

|                                                                              |

| Preliminarily, it appears that vibration of the centrifuge unit upon which   |

| the gauge was mounted may have caused a failure which allowed the source     |

| holder with attached source to fall from the gauge.  Surveys of the relevant |

| areas and smears taken on the source indicate that no source leakage         |

| occurred.                                                                    |

|                                                                              |

| Notified R4DO (K. Kennedy), NMSS EO (S. Frant)                               |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39996       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 07/15/2003|

|    UNIT:  [1] [] []                 STATE:  WI |NOTIFICATION TIME: 15:29[EDT]|

|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        07/15/2003|

+------------------------------------------------+EVENT TIME:        13:40[CDT]|

| NRC NOTIFIED BY:  RICK ROBBINS                 |LAST UPDATE DATE:  07/15/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |KENNETH RIEMER       R3      |

|10 CFR SECTION:                                 |                             |

|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     A/R        Y       100      Power Operation  |0        Hot Standby      |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMATIC REACTOR TRIP                                                       |

|                                                                              |

| "On 07/15/03 at 1340hrs [CDT], the Unit 1 reactor automatically tripped from |

| 100% power upon loss of G-06 rod drive motor-generator (MG) set.  Automatic  |

| transfer of the G-06 MG set to G-07 MG set did not occur.  Automatic         |

| initiation of the auxiliary feedwater occurred.  The cause of the failure of |

| the G-06 rod drive MG set is being investigated.  All systems operated as    |

| expected."                                                                   |

|                                                                              |

|                                                                              |

| G-06 rod drive MG set was carrying the load and running in parallel with rod |

| drive MG set G-07 when it started to smoke.  Rod drive MG set G-06 did not   |

| automatically transfer its load to rod drive MG set G-07.  No fire was seen  |

| and rod drive MG set G-06 was electrically secured.  All rods fully inserted |

| into the core. The first out annunciator for the reactor trip was            |

| overtemperature delta temperature trip.  The Turbine Driven and both Motor   |

| Driven Auxiliary feedwater pumps automatically started as expected.          |

| Currently the licensee is using one train of main feedwater to maintain      |

| proper steam generator water level.  All emergency core cooling systems and  |

| the emergency diesel generators are fully operable if needed.  The           |

| electrical grid is stable.                                                   |

|                                                                              |

| The NRC Resident Inspector was notified of this event by the licensee.       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39997       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 07/15/2003|

|    UNIT:  [1] [2] []                STATE:  TX |NOTIFICATION TIME: 16:35[EDT]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        07/15/2003|

+------------------------------------------------+EVENT TIME:        15:15[CDT]|

| NRC NOTIFIED BY:  MICHAEL SCHAEFER             |LAST UPDATE DATE:  07/15/2003|

|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |LINDA SMITH          R4      |

|10 CFR SECTION:                                 |                             |

|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Refueling        |0        Refueling        |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| 22 OFFSITE EMERGENCY SIRENS INOPERABLE                                       |

|                                                                              |

|                                                                              |

| "South Texas Project is making this eight hour notification IAW 50.72 (b)    |

| (3) (xiii) for "Loss of Offsite Response Capability".  Currently due to      |

| local power outages 10 sirens are available and 22 sirens are not available. |

| Compensatory actions are in place to alert the public if necessary.  There   |

| are three compensatory actions: local law enforcement officials are prepared |

| to respond to areas where the sirens are not available to alert the public,  |

| a community alert network is in place to activate a phone tree to local      |

| residents and tone alert radios with residents.  Power restoration and       |

| recovery actions are in progress."   State and local officials will be       |

| notified of this event by the licensee.                                      |

|                                                                              |

| The NRC Resident Inspector was  notified of this event by the licensee.      |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Fuel Cycle Facility                              |Event Number:   39998       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: WESTINGHOUSE ELECTRIC CORPORATION    |NOTIFICATION DATE: 07/15/2003|

|   RXTYPE: URANIUM FUEL FABRICATION             |NOTIFICATION TIME: 19:05[EDT]|

| COMMENTS: LEU CONVERSION (UF6 to UO2)          |EVENT DATE:        07/15/2003|

|           COMMERCIAL LWR FUEL                  |EVENT TIME:        16:00[EDT]|

|                                                |LAST UPDATE DATE:  07/15/2003|

|    CITY:  COLUMBIA                 REGION:  2  +-----------------------------+

|  COUNTY:  RICHLAND                  STATE:  SC |PERSON          ORGANIZATION |

|LICENSE#:  SNM-1107              AGREEMENT:  Y  |JOHN PELCHAT         R2      |

|  DOCKET:  07001151                             |ROBERT PIERSON       NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  DAVID WILLIAMS               |                             |

|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NBNL                     RESPONSE-BULLETIN      |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| TEMPORARY PROCEDURE TO COMPACT AIR FILTER PAPER NCS FUNCTION WAS NOT         |

| REVIEWED OR APPROVED                                                         |

|                                                                              |

| NRC BULLETIN 91-01 24 HOUR NOTIFICATION                                      |

|                                                                              |

|                                                                              |

| "Time and Date of Event                                                      |

| 23 Jan 2003 - 19 Mar 2003                                                    |

|                                                                              |

| "Reason for Notification                                                     |

|                                                                              |

| "On January 23rd 2003, the process engineer generated a temporary procedure  |

| to compact air filter paper, and did not place the NCS function on review or |

| approval.  The temporary procedure was approved and the process was          |

| performed, in violation of the bounding assumptions of the LLRW ISA (compact |

| filter paper was the end product).  The process engineer later placed the    |

| same process in a formal operating procedure that was reviewed by NCS.  On   |

| February 20th, the NCS  reviewer withheld approval of the formal operating   |

| procedure since the "proposed" process would violate the bounding            |

| assumptions of the ISA and, therefore, require further analysis and an ISA   |

| license annex revision before approval could be given.  The NCS engineer     |

| informed the process engineer that such analysis was necessary and it was    |

| placed in the NCS work queue.  The process engineer did not inform the NCS   |

| engineer that the process had already been performed.  When starting the     |

| safety analysis on June 30th 2003, the NCS engineer found records of         |

| completed filter paper and subsequent investigation revealed the temporary   |

| procedure on July 1, 2003.  The temporary procedure had been retired on      |

| March 19th, although drums of compacted filter media continued to be created |

| in the item control system into at least April 2003.                         |

|                                                                              |

| "Double Contingency Protection                                               |

|                                                                              |

| "The compaction unit is authorized to be used for volume reduction of        |

| noncombustible material that was previously determined to be free of gross   |

| contamination in the originating area, and verified to be free of gross      |

| contamination by the URRS operator before being placed into the compactor.   |

| A criticality would be possible only if an excessive accumulation of uranium |

| occurred with sufficient moderating materials.                               |

|                                                                              |

| "The compactor system was operated outside there documented safety basis     |

| stated in the ISA. A 24- hour notification, therefore, is being issued.      |

|                                                                              |

| "As Found Condition                                                          |

|                                                                              |

| "Drums contained a range of grams U-235 values from near zero to             |

| approximately 50 grams U-235. These low gram U-235 values reflect the low    |

| Uranium loading in the filter media.  The filter paper media is removed from |

| the filters and "tapped" to remove "loose" material, but is not considered   |

| to be "free of gross contamination" due to ability to retain imbedded        |

| material.                                                                    |

|                                                                              |

| "Summary of Activity                                                         |

|                                                                              |

| "1. The process had already been stopped when discovered.                    |

| "2. The content of each drum was reviewed and found to contain less than 50g |

| U-235.                                                                       |

| "3. Selected drums were opened and visually inspected.  All were in a safe   |

| condition.                                                                   |

|                                                                              |

| "Conclusions                                                                 |

|                                                                              |

| "1. Much less than a safe mass was involved.                                 |

| "2. At no time was the health or safety to any employee or member of the     |

| public in jeopardy.                                                          |

| "No exposure to hazardous material was involved.                             |

| "3. The Incident Review Committee (IRC) determined that this is a safety     |

| significant incident in accordance with governing procedures.                |

| "4. Notification was the result of an event, not a deficient NCS analysis.   |

| "5. A causal analysis will be performed."                                    |

|                                                                              |

|                                                                              |

| The certificate holder informed NRC Region 2 (M. Crespo) of this event.      |

+------------------------------------------------------------------------------+



Page Last Reviewed/Updated Thursday, March 25, 2021