Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for February 13, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           02/12/2003 - 02/13/2003



                              ** EVENT NUMBERS **



38513  39470  39545  39571  39575  39579  39580  39581  39582  39583  



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   38513       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 11/23/2001|

|    UNIT:  [1] [] []                 STATE:  FL |NOTIFICATION TIME: 12:30[EST]|

|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        11/23/2001|

+------------------------------------------------+EVENT TIME:        12:10[EST]|

| NRC NOTIFIED BY:  CHARLIE PIKE                 |LAST UPDATE DATE:  02/12/2003|

|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CAUDLE JULIAN        R2      |

|10 CFR SECTION:                                 |                             |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OFFSITE NOTIFICATION TO FLORIDA STATE INVOLVING RECOVERED SEA TURTLE FROM    |

| UNIT 1 INTAKE STRUCTURE                                                      |

|                                                                              |

| "A sea turtle with no external injuries but appearing to be distressed was   |

| recovered from the Unit 1 Intake Structure.  The State Stranding Coordinator |

| for sea turtles has been contacted."                                         |

|                                                                              |

| * * * UPDATE 11/23/01 AT 1255EST FROM CHARLIE PIKE TO S. SANDIN * * *        |

|                                                                              |

| "Turtle has died."                                                           |

|                                                                              |

| The licensee informed both the State of Florida and the NRC Resident         |

| Inspector.                                                                   |

|                                                                              |

| * * * UPDATE 1413EST ON 12/3/01 FROM JACK BREEN TO FANGIE JONES * * *        |

|                                                                              |

| At approximately 1215 EST on 12/3/01, a report was made to the Florida       |

| Department of Fish and Wildlife concerning the recovery of an injured sea    |

| turtle from the plant's intake canal.  The turtle was a green sea turtle in  |

| the intake canal that appeared distressed and looked to have a wound from a  |

| boat motor on its back.  It will be transferred to the State for             |

| rehabilitation.                                                              |

|                                                                              |

| The licensee plans to notify the NRC resident inspector.  Notified           |

| R2DO(MacAlpine).                                                             |

|                                                                              |

| * * * UPDATE 1333EST ON 12/15/01 FROM JACK BREEN TO JOHN MACKINNON * * *     |

|                                                                              |

| At approximately 1215 EST on 12/15/01, a report was made to the Florida      |

| Department of Fish and Wildlife Conservation Commission to pick up a Green   |

| Turtle for rehabilitation. The Green Turtle was taken from the plant's       |

| intake canal, and the turtle appears to have shark bites.                    |

|                                                                              |

| The licensee plans to notify the NRC resident inspector.  Notified R2DO      |

| (Chuck Ogle).                                                                |

|                                                                              |

| * * * UPDATE 1450EST ON 01/06/02 FROM TULLIDGE TO JOHN MACKINNON * * *       |

|                                                                              |

| At 1350EST, a notification to the State of Florida Department of Fish and    |

| Wildlife Conservation Commission was made due to finding an injured          |

| Loggerhead sea turtle in Unit 1 intake. The sea turtle was transported       |

| offsite for rehabilitation. R2DO (Tom Decker) notified.                      |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

|                                                                              |

| ***UPDATE 1330EST ON 4/23/02 FROM JACK BREEN TO RICH LAURA***                |

|                                                                              |

| The licensee rescued a  Loggerhead sea turtle from the intake canal.  The    |

| Florida Fish and Wildlife Conservation Commission was notified, and the      |

| turtle was turned over for rehabilitation.                                   |

|                                                                              |

| The NRC Resident Inspector was informed.  Notified R2DO (B. Bonser).         |

|                                                                              |

| ***UPDATE 1241EDT ON 5/29/02 FROM DAVE WILLIAMS TO RICHARD LAURA***          |

|                                                                              |

| The licensee reported that an offsite notification was made to the Florida   |

| Fish and Wildlife Conservation Commission concerning the discovery of a live |

| loggerhead sea turtle found in the plant's intake canal.  The turtle was     |

| lethargic and was sent for rehabilitation.                                   |

|                                                                              |

| The NRC Resident Inspector was informed.  Notified R2DO (K. Landis).         |

|                                                                              |

| ***** UPDATE AT 1125 EDT ON 06/01/02 FROM CHARLES MARPLE TO LEIGH TROCINE    |

| *****                                                                        |

|                                                                              |

| The following text is a portion of a facsimile received from the licensee:   |

|                                                                              |

| "At 1020 on 06/01/02, a notification was made to the Florida Fish and        |

| Wildlife Conservation Commission regarding a weak and emaciated Loggerhead   |

| turtle found in the plant intake barrier net.  The turtle will be sent       |

| off-site to the Marine Life Center for Rehabilitation."                      |

|                                                                              |

| The licensee notified the NRC resident inspector.  The NRC operations        |

| officer notified the R2DO (Kerry Landis).                                    |

|                                                                              |

| *****UPDATE AT 11:53 EDT ON 6/2/02 FROM MARPLE TO LAURA******                |

|                                                                              |

| "A notification was made to the Florida Fish and Wildlife Conservation       |

| Commission regarding a dead small green sea turtle found in the tangle net.  |

| The turtle will be maintained on ice for a postmortem examination."          |

|                                                                              |

| The NRC resident inspector was notified. Notified R2DO (K. Landis)           |

|                                                                              |

| *****UPDATE AT 12:45 EDT ON 7/18/02 FROM BREEN TO LAURA******                |

|                                                                              |

| A notification was made to the State regarding a dead green sea turtle that  |

| was removed from the intake canal.                                           |

|                                                                              |

| The NRC resident inspector will be notified.                                 |

|                                                                              |

| Notified R2DO (C. Payne                                                      |

|                                                                              |

| ***UPDATE AT 1045 EDT ON 10/20/02 FROM KORTH TO NORRIS***                    |

|                                                                              |

| A Loggerhead turtle was retrieved from the plant's intake canal.  The turtle |

| was in need of rehabilitation.  Per the plant's turtle permit, the Florida   |

| Fish and Wildlife Conservation Commission (FWCC) was notified at 0927 EDT.   |

|                                                                              |

| The NRC Resident Inspector has been notified.                                |

|                                                                              |

| Notified R2DO (Barr)                                                         |

|                                                                              |

| * * * UPDATE AT 1338 EDT ON 10/22/02 FROM KELLY KORTH TO GERRY WAIG * * *    |

|                                                                              |

| A Loggerhead turtle was retrieved from the plant's intake canal.  The turtle |

| was in need of rehabilitation.  Per the plant's turtle permit, the Florida   |

| Fish and Wildlife Conservation Commission (FWCC) was notified at 1250 EDT.   |

|                                                                              |

| The NRC Resident Inspector will be notified by the licensee.                 |

|                                                                              |

| Notified R2DO (Bob Haag)                                                     |

|                                                                              |

| * * * UPDATE ON 11/22/2002 @ 1821 BY FIELDS TO GOULD * * *                   |

|                                                                              |

| The licensee notified the Florida Department of Environmental Protection of  |

| the recovery of a distressed loggerhead sea turtle from their intake canal.  |

| The turtle was taken to a rehabilitation facility.                           |

|                                                                              |

| The NRC Resident inspector will be notified.  Notified R2DO (David Ayres).   |

|                                                                              |

| * * * UPDATE AT 1320 EST ON 12/16/02 FROM BILL PARKS TO GERRY WAIG * * *     |

|                                                                              |

| "On 12-16-02, two loggerhead turtles were retrieved from the plant's intake  |

| canal. The turtles were determined to be in need of rehabilitation. The      |

| injuries to the turtles are not causal to plant operation. Per the plant's   |

| turtle permit, the Florida Fish and Wildlife Conservation Commission (FWCC)  |

| was notified at 1230 EST. This non-emergency notification is being made      |

| pursuant to 10 CFR 50.72(b)(2)(xi) due to the notification of FWCC."         |

|                                                                              |

| The NRC Resident inspector will be notified.  Notified R2DO (Mike Ernstes).  |

|                                                                              |

| * * * UPDATE AT 1350 EST ON 1/25/03 FROM DAVE FIELDS TO MIKE RIPLEY * * *    |

|                                                                              |

| "The State of Florida Department of Environmental Protection was notified    |

| that an injured juvenile loggerhead sea turtle was retrieved from the plant  |

| intake canal.  The turtle was sent to a rehabilitation facility."            |

|                                                                              |

| The NRC Resident inspector will be notified.  Notified R2DO (Ken Barr).      |

|                                                                              |

| * * * * UPDATE AT 1140 EST ON 2/12/03 FROM ALAN HALL TO MIKE RIPLEY * * * *  |

|                                                                              |

|                                                                              |

| On 02/12/03 (approximately 1030 hrs), one loggerhead turtle was retrieved    |

| from the plant's intake canal.  The turtle was determined to be in need of   |

| rehabilitation.  The injury to the turtle is not causal to plant operation.  |

| Per the plant's turtle permit, the Florida Fish and Wildlife Conservation    |

| Commission (FWCC) was notified at 1040 EST.   This non-emergency             |

| notification is being made pursuant to 10 CFR 50.72(b)(2)(xi) due to the     |

| notification of FWCC."                                                       |

|                                                                              |

| The licensee notified the NRC Resident Inspector.  Notified R2 DO (C. Ogle). |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Hospital                                         |Event Number:   39470       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  VA NATIONAL HEALTH PHYSICS PROGRAM   |NOTIFICATION DATE: 12/23/2002|

|LICENSEE:  VA PUGET SOUND HEALTH CARE SYSTEM    |NOTIFICATION TIME: 16:04[EST]|

|    CITY:  SEATTLE                  REGION:  4  |EVENT DATE:        10/22/2002|

|  COUNTY:                            STATE:  WA |EVENT TIME:             [PST]|

|LICENSE#:  46-00990-01           AGREEMENT:  Y  |LAST UPDATE DATE:  02/12/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |LINDA HOWELL         R4      |

|                                                |BOB PIERSON          NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  MICHAEL C. SIMMONS           |                             |

|  HQ OPS OFFICER:  MIKE RIPLEY                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|BLO2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| NICKEL-63 SOURCES INADVERTENTLY DISPOSED OF AS SCRAP                         |

|                                                                              |

| A gas chromatograph, Model HP 5880GLC, with two Ni-63 sources was            |

| inadvertently disposed of with other excess property as scrap metal from the |

| Veterans Administration's Puget Sound Health Care System on 10/22/02 without |

| notifying the RSO.   The loss was discovered on 11/25/02 during a routine    |

| inventory.  The two sealed sources were contained in an electron capture     |

| detector within the gas chromatograph.  The two sources consist of 13.1      |

| millicuries of Ni-63 each (as of 11/25/02).  The source serial numbers are   |

| 89665 and 89474.  The RSO and the Veterans Administration National Health    |

| Physics Program are investigating and will file a written report within 30   |

| days.                                                                        |

|                                                                              |

|                                                                              |

| * * * UPDATE ON 2/12/03 @ 1510 BY SIMMONS TO GOULD  * * *                    |

|                                                                              |

| The licensee reported that the Ni-63  sources were licensed under a general  |

| license and should have been reported under 31.5.c.viii.                     |

|                                                                              |

| Notified R4 DO (Marschall) and NMSS EO (Holahan).                            |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39545       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  WHITING CORPORATION                  |NOTIFICATION DATE: 01/29/2003|

|LICENSEE:                                       |NOTIFICATION TIME: 14:47[EST]|

|    CITY:  MONEE                    REGION:  3  |EVENT DATE:        01/29/2003|

|  COUNTY:                            STATE:  IL |EVENT TIME:             [CST]|

|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  02/12/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |KENNETH RIEMER       R3      |

|                                                |J. BRADLEY FEWELL    R1      |

+------------------------------------------------+KERRY LANDIS         R2      |

| NRC NOTIFIED BY:  FREDERICK TEGGELAAR          |WILLIAM JONES        R4      |

|  HQ OPS OFFICER:  GERRY WAIG                   |TERRY REIS           NRR     |

+------------------------------------------------+JOHN HICKEY          MNSS    |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| 10 CFR 21 NOTIFICATION - WHITING CORPORATION                                 |

|                                                                              |

| "This notice is being sent within the two day period to inform you of a      |

| safety concern related to Whiting cranes sold to utility companies prior to  |

| 1980. The problem was identified through engineering analysis. We are not    |

| aware of any failures.                                                       |

|                                                                              |

| "The concern is specific to the Whiting #25 Hoist Unit (Gear Case). One or   |

| possibly two internal support bolts in this assembly may be significantly    |

| over-stressed.                                                               |

|                                                                              |

| "The exact extent of the over-stressed condition can only be determined by   |

| individual analysis of each hoist in question; however, based on findings, a |

| 50% reduction in rated hoist capacity of the effected cranes will allow for  |

| continued use of the cranes without compromising design safety factors. This |

| limitation should be enforced until the over-stressed bolts have been        |

| replaced or analysis shows that an over-stressed condition does not exist.   |

|                                                                              |

| "Crane owners should contact us at Whiting-Nuclear@WhitingCorp.com and       |

| provide the following information; customer name, contact person, email      |

| address, telephone number, crane serial number and date of next scheduled    |

| outage.                                                                      |

|                                                                              |

| "I trust you find that the notification provided is satisfactory and in      |

| compliance with 10 CFR 21 reporting requirements. If you have any questions, |

| please do not hesitate to contact me at fteggelaar@whitingcorp. com."        |

|                                                                              |

|                                                                              |

| * * * UPDATE ON 2/12/03 @ 1617 BY TEGGELAAR (fax) TO GOULD * * *             |

|                                                                              |

| "This is a follow up notice related to our previously reported 10 CFR 21     |

| dated 1/29/2003. As a result of the ongoing investigation and resolution of  |

| the previous notice, we have identified 5 cranes that utilize a hoist        |

| configuration that does not match the description contained in the previous  |

| notice."                                                                     |

|                                                                              |

| These cranes are at the following facilities:                                |

|                                                                              |

| Indian Point (thought to be Unit 1)                                          |

| Cooper Nuclear Station                                                       |

| WPPSS-Hanford #2 [Columbia Generating]                                       |

| Vermont Yankee                                                               |

| Millstone (Believed to be Unit 1)                                            |

|                                                                              |

| "We have or are attempting to contact these customers directly to notify     |

| them of this circumstance. These are the only additionally impacted          |

| customers we have identified. These were special hoist arrangements using a  |

| # 10 hoist unit (gearcase) as opposed to the previously identified #25 hoist |

| unit.                                                                        |

|                                                                              |

| "The hoist units identified above are to be limited to 20% of rated capacity |

| to prevent compromising design factors, until such time as the Units can be  |

| upgraded."                                                                   |

|                                                                              |

| Notified R1 DO (Meyer), R2 DO (Lesser), R3 DO (Burgess), R4 DO (Marschall),  |

| NRR (Foster), NRR (Zwolinski).                                               |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39571       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 02/06/2003|

|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 19:04[EST]|

|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        02/06/2003|

+------------------------------------------------+EVENT TIME:        12:11[EST]|

| NRC NOTIFIED BY:  RICHARD ALEXANDER            |LAST UPDATE DATE:  02/12/2003|

|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |JAMES NOGGLE         R1      |

|10 CFR SECTION:                                 |CYNTHIA CARPENTER    NRR     |

|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| UNANALYZED CONDITION FOR CABLE SEPARATION CRITERIA AT INDIAN POINT 2         |

|                                                                              |

| "At 1600 hours on February 6, 2003, IP determined that CR IP-2002.00765,     |

| issued to identify that the routing of charging pump power supply and        |

| control cables does not meet the cable separation criteria specified in      |

| 10CFR50 App R section III.G.1, was reportable as a potentially unanalyzed    |

| condition.  This condition was discovered during the re-baseline of the      |

| 10CFR50 Appendix R analysis.  A fire in Fire Area F could potentially        |

| disable all 3 charging pumps as a result of the loss of the 23 charging pump |

| alternate power feed transfer switch; loss of the 23 charging pump           |

| 'alternate' power feed cable, and the alternate/normal power feed cable      |

| between the transfer switch and the pump; loss of 22CHP power feed cable;    |

| loss of local/remote control cable, PL2, disabling remote operation for all  |

| 3 charging pump breakers; and loss of Control cables and pneumatics 22 and   |

| 23 charging pumps.  Fire protection impairment actions were implemented per  |

| Procedure SAO-703.  This condition was determined to be reportable using the |

| guidance of NUREG-1022 which cites the absence of adequate separation        |

| between redundant shutdown trains to be reportable as a significant          |

| degradation of plant safety.  Although it is possible that this condition    |

| was previously identified and dispositioned, an analysis is not readily      |

| available."                                                                  |

|                                                                              |

| The NRC Resident Inspector has been notified.                                |

|                                                                              |

| * * * UPDATE ON 2/12/03 @ 1757 BY DURR TO GOULD * * *                        |

|                                                                              |

| Event notification 39571 made on February 6, 2003 identified an unanalyzed   |

| cable separation issue discovered during the re-baseline of the 10 CFR 50,   |

| Appendix R, analysis.  As part of the on-going re-baseline, CR-IP-2003-867   |

| was written at 1353 hours on February 12, 2003 to identify the potential     |

| failure of normal power supply cables for the six service water pumps to     |

| meet the separation criteria of 10 CFR 50, Appendix R, Section III,G. 1. The |

| cables are potentially vulnerable to the effects of a single postulated fire |

| in fire area J.  The specific location of this common vulnerability is       |

| Manhole 23, located on the 15 foot elevation of the turbine building         |

| adjacent to the northwest corner of the 6.9 kV switchgear cabinets. Manhole  |

| 23 is covered by a checkered plate that is open to the 15 foot elevation and |

| has not been credited as a fire barrier.  The normal power supply cables are |

| credited for a fire in Fire Area J to supply power to at least one service   |

| water pump.  The normal power supplies for the six service water pumps are   |

| routed from the 480 V Switchgear Room through manhole 23.  Fire protection   |

| impairment actions are taken per Procedure SAO-703. Although it is possible  |

| this condition was also previously identified and dispositioned, the         |

| analysis is not readily available for assessment as part of the re-baseline. |

|                                                                              |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

|                                                                              |

| Notified R1 DO (Meyer) and NRR EO (Zwolinski).                               |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39575       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  MA RADIATION CONTROL PROGRAM         |NOTIFICATION DATE: 02/10/2003|

|LICENSEE:  PERKINELMER LIFE SCIENCES            |NOTIFICATION TIME: 14:29[EST]|

|    CITY:  BOSTON                   REGION:  1  |EVENT DATE:        07/18/2002|

|  COUNTY:                            STATE:  MA |EVENT TIME:             [EST]|

|LICENSE#:  00-3200               AGREEMENT:  Y  |LAST UPDATE DATE:  02/10/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |GLENN MEYER          R1      |

|                                                |DON COOL     EO      NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  CARPENITO                    |                             |

|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| POTENTIALLY MISSING  PHOSPHORUS-32 SHIPPING PACKAGES                         |

|                                                                              |

| Single packages containing P-32 (~14 day half-life) were destined for four   |

| different out-of-state locations (in CA, KS, NY and TX). Intended shipping   |

| dates were July 18 (2), August 5 and August 6, 2002. Carrier reported        |

| packages potentially missing within 2-3 days after intended shipping dates.  |

| The per-package activities ranged from 250 microcuries to 1 millicurie. All  |

| subject radioactive material contents are presently well past ten            |

| half-lives. After several months of shipper-carrier joint investigation, the |

| cause(s) remain undetermined. Actions have been taken by shipper and carrier |

| to prevent recurrence.                                                       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39579       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: CATAWBA                  REGION:  2  |NOTIFICATION DATE: 02/12/2003|

|    UNIT:  [1] [2] []                STATE:  SC |NOTIFICATION TIME: 13:46[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        02/12/2003|

+------------------------------------------------+EVENT TIME:        09:45[EST]|

| NRC NOTIFIED BY:  Mc CONNELL                   |LAST UPDATE DATE:  02/12/2003|

|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |MARK LESSER          R2      |

|10 CFR SECTION:                                 |                             |

|AINA 50.72(b)(3)(v)(A)   POT UNABLE TO SAFE SD  |                             |

|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LOSS OF SAFETY FUNCTION ON BOTH UNITS DUE TO TWO EMERGENCY D/G's BEING       |

| DECLARED INOPERABLE                                                          |

|                                                                              |

| Emergency Diesel Generator "2A" was removed from service for  pre-planned    |

| maintenance.  This condition renders the "2A" Nuclear service Water pump     |

| inoperable.   They had a vital i/c inverter "2EID"  to fail, rendering the   |

| "2B" Emergency Diesel Generator inoperable due to its fuel oil fill valve    |

| failing closed.   By the "2B" Diesel Generator being inoperable it rendered  |

| the "2B" Nuclear Service Water pump inoperable.  The Nuclear Service Water   |

| is shared between both units.  A loss of safety function occurred on Unit 2  |

| due to two Diesel Generators being inoperable and no Nuclear Service Water   |

| train being operable.   Since the Nuclear Service Water system is a shared   |

| with Unit 1, it also experienced a loss of a safety function.  The system    |

| was returned to service within 9 minutes after re-opening the fuel oil fill  |

| bypass valve which rendered  Diesel Generator "2B" operable again.           |

|                                                                              |

|                                                                              |

| The NRC Resident Inspector was notified.   State and Local agencies will be  |

| notified.                                                                    |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39580       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  ABC LABORATORIES                     |NOTIFICATION DATE: 02/12/2003|

|LICENSEE:  ABC LABORATORIES                     |NOTIFICATION TIME: 15:19[EST]|

|    CITY:  COLUMBIA                 REGION:  3  |EVENT DATE:        02/08/2003|

|  COUNTY:                            STATE:  MO |EVENT TIME:             [CST]|

|LICENSE#:  24-13365-01           AGREEMENT:  N  |LAST UPDATE DATE:  02/12/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |SONIA BURGESS        R3      |

|                                                |PATRICIA HOLAHAN     NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  VOLLMER                      |                             |

|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|BLO2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| MISSING NICKEL-63 FOIL SOURCE                                                |

|                                                                              |

| The licensee, ABC Laboratories of Columbia, Mo., reported they had lost a    |

| <15 millicurie Ni-63 foil source (serial # F2288) that had been removed from |

| a Gas Chromatograph Chemical Detector and placed in storage.  They think it  |

| may be in a dryer at the lab.                                                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39581       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: PALO VERDE               REGION:  4  |NOTIFICATION DATE: 02/12/2003|

|    UNIT:  [] [2] []                 STATE:  AZ |NOTIFICATION TIME: 16:13[EST]|

|   RXTYPE: [1] CE,[2] CE,[3] CE                 |EVENT DATE:        02/07/2003|

+------------------------------------------------+EVENT TIME:        17:20[MST]|

| NRC NOTIFIED BY:  MARKS                        |LAST UPDATE DATE:  02/12/2003|

|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |CHARLES MARSCHALL    R4      |

|10 CFR SECTION:                                 |                             |

|AINC 50.72(b)(3)(v)(C)   POT UNCNTRL RAD REL    |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     N          Y       98       Power Operation  |98       Power Operation  |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| LEAKAGE DISCOVERED FROM HIGH PRESSURE SAFETY INJECTION SYSTEM OUTSIDE        |

| CONTAINMENT                                                                  |

|                                                                              |

| "On February 7, 2003, at approximately 17:20 Mountain Standard Time (MST),   |

| Palo Verde Unit 2 discovered leakage from the high pressure safety injection |

| system outside containment that could contain highly radioactive fluids      |

| during a serious transient or accident exceeded the safety analysis leakrate |

| limit. The drain valve that was the source of the leakage was promptly       |

| tightened to return to within the analysis limit and subsequently repaired   |

| to further reduce leakage to a level as low as practicable. There was no     |

| release of radioactivity to the environment as a result of this event.       |

| There were no adverse safety consequences resulting from the event.          |

|                                                                              |

| The "loss of safety function" reporting requirement would be triggered by    |

| the described condition because the post-LOCA dose calculations assume no    |

| more than 1500 ml/hour leakage outside of containment in the 10 CFR 100      |

| siting analysis.  At the time of discovery, the leakage was 1715 ml/min      |

| (102900 ml/hr). Therefore the safety function to control the release of      |

| radioactive material such that the dose to a member of the public would not  |

| exceed 10 CFR 100 limits during a potential LOCA was not fulfilled.          |

|                                                                              |

| At the time of the discovery the condition was promptly corrected so no ENS  |

| report was thought to be required, however on further review it was noted    |

| that the reporting requirement states "Any event or condition that at the    |

| time of discovery could have prevented.." and therefore remains immediately  |

| reportable even if the condition no longer exists."                          |

|                                                                              |

|                                                                              |

| The NRC Resident Inspector was notified.                                     |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39582       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 02/12/2003|

|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 16:41[EST]|

|   RXTYPE: [1] GE-3                             |EVENT DATE:        02/12/2003|

+------------------------------------------------+EVENT TIME:        09:45[CST]|

| NRC NOTIFIED BY:  NEVE                         |LAST UPDATE DATE:  02/12/2003|

|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |SONIA BURGESS        R3      |

|10 CFR SECTION:                                 |                             |

|HFIT 26.73               FITNESS FOR DUTY       |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| SUPERVISOR TESTED POSITIVE FOR ALCOHOL IN RANDOM TEST                        |

|                                                                              |

| COMPENSATORY MEASURES PUT IN PLACE WHEN DISCOVERED.                          |

|                                                                              |

| NRC RESIDENT INSPECTOR WAS NOTIFIED                                          |

|                                                                              |

| CONTACT HOO FOR ADDITIONAL INFORMATION                                       |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39583       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 02/12/2003|

|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 21:21[EST]|

|   RXTYPE: [1] GE-3                             |EVENT DATE:        02/12/2003|

+------------------------------------------------+EVENT TIME:        17:04[CST]|

| NRC NOTIFIED BY:  LAUDENBACH                   |LAST UPDATE DATE:  02/12/2003|

|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |SONIA BURGESS        R3      |

|10 CFR SECTION:                                 |                             |

|AINA 50.72(b)(3)(v)(A)   POT UNABLE TO SAFE SD  |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| HIGH PRESSURE COOLANT INJECTION (HPCI) DECLARED INOPERABLE DURING TESTING    |

|                                                                              |

| During a test of HPCI, the flow controller failed as the controller was      |

| being transferred from manual to balance.  The system was manually  tripped  |

| and remains inoperable.  The system impacted is the High Pressure Coolant    |

| Injection and the cause is being investigated.  The plant is also in a LCO   |

| action statement.  Corrective action is being implemented to correct this    |

| single train system failure.                                                 |

|                                                                              |

| The NRC Resident Inspector was notified.   State and local agencies will be  |

| notified.                                                                    |

+------------------------------------------------------------------------------+





                    